1.
Rev Port Cardiol (Engl Ed) ; 38(6): 451-455, 2019 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31320221

RESUMO

INTRODUCTION: Sleep Apnea Syndrome (SAS) is a prevalent respiratory disease with marked expression in the population with cardiovascular disease. The diagnosis is based on polysomnography. In patients with cardiac implantable electronic devices (CIED), the prevalence of SAS may reach 60%. The objective of this study was to evaluate the value of DEC in the SAS screening. METHODS: Prospective study that included patients with CIED with sleep apnea algorithm. The frequency response function was activated and simplified polygraphy was performed. The data of the device were collected on the day of the polygraph. RESULTS: The sample included 29 patients, with a mean age of 76.1 years, 71.4% of the male gender. The prevalence of SAS was 77%. For SAS, the agreement between polysomnography and the Pacemaker was Kappa = 0.54 (p = 0.001), 95% CI (0.28, 0.81) (moderate agreement); for moderate to severe SAS, the agreement was Kappa = 0.73 (p <0.001), 95% CI (0.49, 0.976) (substantial agreement). Severe SAS was obtained: sensitivity 60%, specificity 100%, positive predictive value 100%, negative predictive value 60% and diagnostic accuracy 75%; for moderate to severe SAS: sensitivity of 90%, specificity of 83%, positive predictive values of 90% and negative of 87.5%, with a diagnostic accuracy of 87.5%. CONCLUSION: SAS is highly prevalent in patients with CIED. The values obtained through these devices have a strong positive correlation with the Apnea-Hypopnea Índex, which makes them a good tool for the screening of severe SAS.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Polissonografia/métodos , Síndromes da Apneia do Sono/diagnóstico , Idoso , Algoritmos , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Síndromes da Apneia do Sono/etiologia
2.
Eur J Echocardiogr ; 11(7): E28, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20219769

RESUMO

Mitral and aortic valve aneurysms are uncommon, but the coexistence of both mitral and aortic valve aneurysms in the same patient is a rather unusual finding in the literature. We report a rare clinical case of a patient with both mitral and aortic valve aneurysms and a rupture of the mitral valve aneurysm, as the main echocardiographic manifestations of infective endocarditis. This clinical case emphasizes infective endocarditis as the most frequent cause of valve aneurysms, reminding that this diagnosis should be suspected even in the absence of vegetations. This case demonstrates that transoesophageal echocardiography plays a major role on diagnosis of valve aneurysms, revealing the rupture of the mitral valve aneurysm and defining this rupture as the main mechanism of mitral valve regurgitation. This case also underlines the role of transoesophageal echocardiography on management decisions, allowing a morphological evaluation of the mitral valve and selection of the appropriate surgical strategy.


Assuntos
Aneurisma Roto/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Endocardite Bacteriana/complicações , Aneurisma Cardíaco/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Antibacterianos/uso terapêutico , Ecocardiografia , Ecocardiografia Doppler em Cores/métodos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Ruptura Espontânea , Resultado do Tratamento