Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Argent Microbiol ; 34(1): 52-6, 2002.
Artigo em Espanhol | MEDLINE | ID: mdl-11942084

RESUMO

The investigation of methicillin resistance in Staphylococcus aureus (MRSA) is a serious problem for the physician and microbiologist. Accurate and rapid detection is essential for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of the resistant strain. The performance characteristics of the MicroScan Overnight Conventional Pos Combo 12 panels (MOCP), BBL Crystal MRSA ID (CR), E-test and agar screen plate (Muller Hinton agar with oxacillin 6 micrograms/ml and 4% NaCl) (AS) were evaluated for the detection of oxacillin resistance. Thirty S. aureus clinically significant strains with different PFGE (Pulse Field Gel Electrophoresis) banding pattern were tested, and 22 of them were mecA positive by PCR. These strains were also analyzed by mecA and Tn554 polymorphism. All mecA positive strains were classified as methicillin resistant by MOCP and E-test. CR and AS failed to detect oxacillin resistance in 2 strains. One false positive was only detected by E-test. Accurate testing for the presence of MRSA may reduce the need for empiric therapy with vancomycin for patients with staphylococcal infections. According to our results the best performance was obtained with MOCP. However, as a rapid method, CR gave acceptable sensitivity for clinical purposes.


Assuntos
Proteínas de Bactérias/análise , Proteínas de Transporte/análise , Hexosiltransferases , Resistência a Meticilina , Testes de Sensibilidade Microbiana/métodos , Muramilpentapeptídeo Carboxipeptidase/análise , Peptidil Transferases , Staphylococcus aureus/efeitos dos fármacos , Meios de Cultura , Resistência a Medicamentos/genética , Farmacorresistência Bacteriana Múltipla/genética , Eletroforese em Gel de Campo Pulsado , Humanos , Resistência a Meticilina/genética , Oxacilina/farmacologia , Proteínas de Ligação às Penicilinas , Reação em Cadeia da Polimerase , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/genética , Vancomicina/farmacologia
2.
Rev. argent. microbiol ; 34(1): 52-6, 2002 Jan-Mar.
Artigo em Espanhol | LILACS-Express | LILACS, BINACIS | ID: biblio-1171697

RESUMO

The investigation of methicillin resistance in Staphylococcus aureus (MRSA) is a serious problem for the physician and microbiologist. Accurate and rapid detection is essential for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of the resistant strain. The performance characteristics of the MicroScan Overnight Conventional Pos Combo 12 panels (MOCP), BBL Crystal MRSA ID (CR), E-test and agar screen plate (Muller Hinton agar with oxacillin 6 micrograms/ml and 4


NaCl) (AS) were evaluated for the detection of oxacillin resistance. Thirty S. aureus clinically significant strains with different PFGE (Pulse Field Gel Electrophoresis) banding pattern were tested, and 22 of them were mecA positive by PCR. These strains were also analyzed by mecA and Tn554 polymorphism. All mecA positive strains were classified as methicillin resistant by MOCP and E-test. CR and AS failed to detect oxacillin resistance in 2 strains. One false positive was only detected by E-test. Accurate testing for the presence of MRSA may reduce the need for empiric therapy with vancomycin for patients with staphylococcal infections. According to our results the best performance was obtained with MOCP. However, as a rapid method, CR gave acceptable sensitivity for clinical purposes.

3.
Rev. argent. microbiol ; 34(1): 52-6, 2002 Jan-Mar.
Artigo em Espanhol | BINACIS | ID: bin-39265

RESUMO

The investigation of methicillin resistance in Staphylococcus aureus (MRSA) is a serious problem for the physician and microbiologist. Accurate and rapid detection is essential for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of the resistant strain. The performance characteristics of the MicroScan Overnight Conventional Pos Combo 12 panels (MOCP), BBL Crystal MRSA ID (CR), E-test and agar screen plate (Muller Hinton agar with oxacillin 6 micrograms/ml and 4


NaCl) (AS) were evaluated for the detection of oxacillin resistance. Thirty S. aureus clinically significant strains with different PFGE (Pulse Field Gel Electrophoresis) banding pattern were tested, and 22 of them were mecA positive by PCR. These strains were also analyzed by mecA and Tn554 polymorphism. All mecA positive strains were classified as methicillin resistant by MOCP and E-test. CR and AS failed to detect oxacillin resistance in 2 strains. One false positive was only detected by E-test. Accurate testing for the presence of MRSA may reduce the need for empiric therapy with vancomycin for patients with staphylococcal infections. According to our results the best performance was obtained with MOCP. However, as a rapid method, CR gave acceptable sensitivity for clinical purposes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...