RESUMO
BACKGROUND: Clostridium perfringens is an unusual pathogen responsible for the development of a gas-forming pyogenic liver abscess. Progression to septicemia with this infection has amplified case fatality rates. CASE REPORT: We report a case of an 81-year-old lady with pyogenic liver abscess with gas formation that was preceded by an acute gastroenteritis. The most common precipitating factors are invasive procedures and immunosuppression. Clostridium perfringens was unexpectedly isolated in the drained abscess, as well as blood. It is a normal inhabitant of the human bowel and a common cause of food poisoning, notoriously leading to tissue necrosis and gas gangrene. CONCLUSIONS: We report a case of gas-forming pyogenic liver abscess and bacteremia progressing to fatal septic shock, caused by an uncommon Clostridium perfringens isolate.
Assuntos
Infecções por Clostridium/complicações , Clostridium perfringens , Gastroenterite/complicações , Abscesso Hepático Piogênico/microbiologia , Insuficiência de Múltiplos Órgãos/microbiologia , Choque Séptico/microbiologia , Idoso de 80 Anos ou mais , Infecções por Clostridium/diagnóstico , Infecções por Clostridium/terapia , Evolução Fatal , Feminino , Gastroenterite/diagnóstico , Gastroenterite/terapia , Humanos , Abscesso Hepático Piogênico/diagnóstico , Abscesso Hepático Piogênico/terapia , Insuficiência de Múltiplos Órgãos/diagnóstico , Insuficiência de Múltiplos Órgãos/terapiaRESUMO
Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance (true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.