Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(11): 113521, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461552

RESUMO

Time-resolved x-ray self-emission imaging of hot spots in inertial confinement fusion experiments along several lines of sight provides critical information on the pressure and the transient morphology of the hot spot on the University of Rochester's OMEGA Laser System. At least three quasi-orthogonal lines of sight are required to infer the tomographic information of the hot spots of deuterium-tritium cryogenic layered implosions. OMEGA currently has two time-gated x-ray hot-spot imagers: the time-resolved Kirkpatrick-Baez x-ray microscope and the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI). The time-gated x-ray hot-spot imager (XRHSI) is being developed for use on OMEGA as the third line of sight for the high-yield operation of up to 4 × 1014 neutrons. XRHSI follows the SLOS-TRXI concept; however, it will have improved spatial and temporal resolutions of 5 µm and 20 ps, respectively. The simultaneous operation of the three instruments will provide 3-D reconstructions of the assembled hot-spot fuel at various times through peak thermonuclear output. The technical approach consists of a pinhole array imager and demagnifying time-dilation drift tube that are coupled to two side-by-side hybrid complementary metal-oxide semiconductor (hCMOS) image sensors. To minimize the background and to harden the diagnostics, an angled drift-tube assembly shifting the hCMOS sensors out of the direct line of sight and neutron shielding will be applied. The technical design space for the instrument will be discussed and the conceptual design will be presented.

2.
Rev Sci Instrum ; 89(10): 10I137, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399690

RESUMO

A new ultra-fast photomultiplier tube and associated drivers have been developed for use in the next generation of gamma-ray high pressure gas Cherenkov detectors for inertial confinement fusion experiments at the National Ignition Facility. Pulse-dilation technology has been applied to a standard micro-channel-plate-based photomultiplier tube to improve the temporal response by about 10×. The tube has been packaged suitably for deployment on the National Ignition Facility, and remote electronics have been designed to deliver the required non-linear waveforms to the pulse dilation electrode. This is achieved with an avalanche pulse generator system capable of generating fast arbitrary waveforms over the useful parameter space. The pulse is delivered via fast impedance-matching transformers and isolators, allowing the cathode to be ramped on a sub-nanosecond time scale between two high voltages in a controlled non-linear manner. This results in near linear pulse dilation over several ns. The device has a built-in fiducial system that allows easy calibration and testing with fiber optic laser sources. Results are presented demonstrating the greatly improved response time and other parameters of the device.

3.
Rev Sci Instrum ; 89(10): 10G123, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399697

RESUMO

A new generation of fast-gated x-ray framing cameras have been developed that are capable of capturing multiple frames along a single line-of-sight with 30 ps temporal resolution. The instruments are constructed by integrating pulse-dilation electron imaging with burst mode hybrid-complimentary metal-oxide-semiconductor sensors. Two such instruments have been developed, characterized, and fielded at the National Ignition Facility and the OMEGA laser. These instruments are particularly suited for advanced x-ray imaging applications in Inertial Confinement Fusion and High energy density experiments. Here, we discuss the system architecture and the techniques required for tuning the instruments to achieve optimal performance. Characterization results are also presented along with planned future improvements to the design.

4.
Rev Sci Instrum ; 89(10): 10G117, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399700

RESUMO

The single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium-tritium shells in inertial confinement fusion experiments in the ∼4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16-channel, framing-camera-based, time-resolved Kirkpatrick-Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ∼40-ps temporal resolution and better than 10-µm spatial resolution. Shots with neutron yields of up to 1 × 1014 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

5.
Rev Sci Instrum ; 89(10): 10G125, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399712

RESUMO

Crystal x-ray imaging is frequently used in inertial confinement fusion and laser-plasma interaction applications as it has advantages compared to pinhole imaging, such as higher signal throughput, better achievable spatial resolution, and chromatic selection. However, currently used x-ray detectors are only able to obtain a single time resolved image per crystal. The dilation aided single-line-of-sight x-ray camera described here was designed for the National Ignition Facility (NIF) and combines two recent diagnostic developments, the pulse dilation principle used in the dilation x-ray imager and a ns-scale multi-frame camera that uses a hold and readout circuit for each pixel. This enables multiple images to be taken from a single-line-of-sight with high spatial and temporal resolution. At the moment, the instrument can record two single-line-of-sight images with spatial and temporal resolution of 35 µm and down to 35 ps, respectively, with a planned upgrade doubling the number of images to four. Here we present the dilation aided single-line-of-sight camera for the NIF, including the x-ray characterization measurements obtained at the COMET laser, as well as the results from the initial timing shot on the NIF.

6.
Rev Sci Instrum ; 89(10): 10I146, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399731

RESUMO

The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ∼100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ∼10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.

7.
Rev Sci Instrum ; 89(6): 063506, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29960515

RESUMO

A pulse-dilation photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution has been developed for use with γ-ray-sensitive gas Cherenkov detectors at the National Ignition Facility to improve the diagnosis of nuclear fusion burn history and the areal density of the remaining capsule ablator. The pulse-dilation mechanism entails the application of a time-dependent, ramp waveform to a photocathode-mesh structure, introducing a time-dependent photoelectron accelerating potential. The electric field imparts axial velocity dispersion to outgoing photoelectrons. The photoelectron pulse is dilated as it transits a drift region prior to amplification in a microchannel plate and read out with a digital oscilloscope. We report the first measurements with the prototype PD-PMT demonstrating nominal <20 ps FWHM across a 400 ps measurement window and <30 ps FWHM for an extracted charge up to 300 pC. The output peak areas are linear to within 20% over 3 orders of magnitude of input intensity. 3D particle in cell simulations, which included space charge effects, have been carried out to investigate the device temporal magnification, resolution, and linearity.

8.
Rev Sci Instrum ; 88(1): 013707, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147687

RESUMO

We report the characterisation of gated optical image intensifiers for fluorescence lifetime imaging, evaluating the performance of several different prototypes that culminate in a new design that provides improved spatial resolution conferred by the addition of a magnetic field to reduce the lateral spread of photoelectrons on their path between the photocathode and microchannel plate, and higher signal to noise ratio conferred by longer time gates. We also present a methodology to compare these systems and their capabilities, including the quantitative readouts of Förster resonant energy transfer.

9.
Rev Sci Instrum ; 87(11): 11E202, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910532

RESUMO

We report simulations and experiments that demonstrate an increase in spatial resolution of the NIF core diagnostic x-ray streak cameras by at least a factor of two, especially off axis. A design was achieved by using a corrector electron optic to flatten the field curvature at the detector plane and corroborated by measurement. In addition, particle in cell simulations were performed to identify the regions in the streak camera that contribute the most to space charge blurring. These simulations provide a tool for convolving synthetic pre-shot spectra with the instrument function so signal levels can be set to maximize dynamic range for the relevant part of the streak record.

10.
Rev Sci Instrum ; 85(11): 11E504, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430346

RESUMO

The DIlation X-ray Imager (DIXI) is a new, high-speed x-ray framing camera at the National Ignition Facility (NIF) sensitive to x-rays in the range of ≈2-17 keV. DIXI uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps, a ≈10× improvement over conventional framing cameras currently employed on the NIF (≈100 ps resolution), and otherwise only attainable with 1D streaked imaging. The pulse-dilation technique utilizes a voltage ramp to impart a velocity gradient on the signal-bearing electrons. The temporal response, spatial resolution, and x-ray sensitivity of DIXI are characterized with a short x-ray impulse generated using the COMET laser facility at Lawrence Livermore National Laboratory. At the NIF a pinhole array at 10 cm from target chamber center (tcc) projects images onto the photocathode situated outside the NIF chamber wall with a magnification of ≈64×. DIXI will provide important capabilities for warm-dense-matter physics, high-energy-density science, and inertial confinement fusion, adding important capabilities to temporally resolve hot-spot formation, x-ray emission, fuel motion, and mix levels in the hot-spot at neutron yields of up to 10(17). We present characterization data as well as first results on electron-transport phenomena in buried-layer foil experiments.

11.
Rev Sci Instrum ; 83(10): 10E116, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126938

RESUMO

As the yield on implosion shots increases it is expected that the peak x-ray emission reduces to a duration with a FWHM as short as 20 ps for ∼7 × 10(18) neutron yield. However, the temporal resolution of currently used gated x-ray imagers on the NIF is 40-100 ps. We discuss the benefits of the higher temporal resolution for the NIF and present performance measurements for dilation x-ray imager, which utilizes pulse-dilation technology [T. J. Hilsabeck et al., Rev. Sci. Instrum. 81, 10E317 (2010)] to achieve x-ray imaging with temporal gate times below 10 ps. The measurements were conducted using the COMET laser, which is part of the Jupiter Laser Facility at the Lawrence Livermore National Laboratory.

12.
Rev Sci Instrum ; 81(10): 10E317, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034015

RESUMO

A 5 ps gated framing camera was demonstrated using the pulse-dilation of a drifting electron signal. The pulse-dilation is achieved by accelerating a photoelectron derived information pulse with a time varying potential [R. D. Prosser, J. Phys. E 9, 57 (1976)]. The temporal dependence of the accelerating potential causes a birth time dependent axial velocity dispersion that spreads the pulse as it transits a drift region. The expanded pulse is then imaged with a conventional gated microchannel plate based framing camera and the effective gating time of the combined instrument is reduced over that of the framing camera alone. In the drift region, electron image defocusing in the transverse or image plane is prevented with a large axial magnetic field. Details of the unique issues associated with rf excited photocathodes were investigated numerically and a prototype instrument based on this principle was recently constructed. Temporal resolution of the instrument was measured with a frequency tripled femtosecond laser operating at 266 nm. The system demonstrated 20× temporal magnification and the results are presented here. X-ray image formation strategies and photometric calculations for inertial confinement fusion implosion experiments are also examined.

13.
Rev Sci Instrum ; 79(10): 10F502, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044647

RESUMO

Conventional in-line high speed streak cameras have fundamental issues when their performance is extended below a picosecond. The transit time spread caused by both the spread in the photoelectron (PE) "birth" energy and space charge effects causes significant electron pulse broadening along the axis of the streak camera and limits the time resolution. Also it is difficult to generate a sufficiently large sweep speed. This paper describes a new instrument in which the extraction electrostatic field at the photocathode increases with time, converting time to PE energy. A uniform magnetic field is used to measure the PE energy, and thus time, and also focuses in one dimension. Design calculations are presented for the factors limiting the time resolution. With our design, subpicosecond resolution with high dynamic range is expected.

14.
Opt Lett ; 29(19): 2249-51, 2004 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-15524370

RESUMO

We report the development of a high-speed wide-field fluorescence-lifetime imaging (FLIM) system that provides fluorescence-lifetime images at rates of as many as 29 frames/s. A FLIM multiwell plate reader and a potentially portable FLIM endoscopic system operating at 355-nm excitation have been demonstrated.


Assuntos
Algoritmos , Endoscópios , Interpretação de Imagem Assistida por Computador/métodos , Microscopia de Fluorescência/métodos , Sistemas On-Line/instrumentação , Espectrometria de Fluorescência/métodos , Gravação em Vídeo/instrumentação , Endoscopia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Gravação em Vídeo/métodos
15.
Opt Lett ; 23(10): 810-2, 1998 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-18087350

RESUMO

We describe a novel whole-field fluorescence lifetime imaging system, based on a time-gated image intensifier and a solid-state laser oscillator-amplifier, that images lifetime differences of less than 10 ps. This system was successfully applied to discrimination between biological tissue constituents.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...