PURPOSE: To compare shear wave elastography (SWE) and Afirma™ gene expression classifier (GEC) for diagnosis of malignancy in thyroid nodules (TNs) with Bethesda Classification (BC) III or IV indeterminate cytology. METHODS: This preliminary single-center prospective study was approved by the Institutional Review Board. We evaluated 151 consented patients with 151 indeterminate TNs (123 BC III, 28 BC IV) on fine-needle aspiration biopsy (FNAB). B-mode ultrasound, vascularity, and SWE were performed prior to FNAB. TN stiffness was measured as shear wave velocity (SWV) in meters per second (m/s). The stiffest area of the TN was selected for SWV measurement. GEC testing was performed with a second FNAB. Surgery was recommended for GEC-suspicious TNs, or GEC-benign TNs with two or more worrisome B-mode US features. RESULTS: Surgical pathology confirmed 31 malignant TNs. Among the GEC-suspicious group, 28 of 59 TNs were malignant. The SWV value of ≥3.59 m/s was the best cut-off for malignancy risk based on the receiver operating curve (ROC). Twenty-six malignant TNs had SWV ≥ 3.59 m/s. The sensitivity and specificity for SWV ≥ 3.59 m/s were 83.9 and 79.2%, respectively. Positive predictive value (PPV) was 51.0% and negative predictive value (NPV) was 95.0%. For the GEC-suspicious group, sensitivity, specificity, PPV, and NPV were 90.3, 74.2, 47.5, and 96.7%, respectively. In multivariate analysis, SWV and GEC-suspicious were significant predictors of malignancy, but B-mode features and vascularity were not. CONCLUSION: This preliminary study indicates that SWE and GEC are independent predictors of malignancy in TNs with BC III or IV.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/genética , Adulto , Idoso , Biópsia por Agulha Fina , Feminino , Perfilação da Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia
2.
Eur J Radiol ; 85(9): 1586-93, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27501893

RESUMO

OBJECTIVES: This study prospectively determines the shear wave elastography characteristics of parathyroid adenomas using virtual touch imaging quantification, a non-invasive ultrasound based shear wave elastography method. METHODS: This prospective study examined 57 consecutive patients with biochemically proven primary hyperparathyroidism and solitary parathyroid adenoma identified by ultrasound and confirmed by at least one of the following: surgical resection, positive Technetium-99m Sestamibi Scintigraphy (MIBI) scan, or fine needle aspiration biopsy with positive PTH washout (performed only in MIBI negative patients). Vascularity and shear wave elastography were performed for all patients. Parathyroid adenoma stiffness was measured as shear wave velocity in meters per second. RESULTS: The median (range) pre-surgical value for PTH and calcium were 58pg/mL (19, 427) and 10.8mg/dL (9.5, 12.1), respectively. 37 patients had positive MIBI scan. 20 patients had negative MIBI scan but diagnosis was confirmed with positive PTH washout. 42 patients underwent parathyroidectomy, and an adenoma was confirmed in all. The median (range) shear wave velocity for all parathyroid adenomas enrolled in this study was 2.02m/s (1.53, 2.50). The median (range) shear wave velocity for thyroid tissue was 2.77m/s (1.89, 3.70). The shear wave velocity of the adenomas was independent of adenoma size, serum parathyroid hormone concentration, or plasma parathyroid hormone concentration. CONCLUSIONS: Tissue elasticity of parathyroid adenoma is significantly lower than thyroid tissue. B-mode features and distinct vascularity pattern are helpful tools in diagnosing parathyroid adenoma with ultrasound. Shear wave elastography may provide valuable information in diagnosing parathyroid adenoma.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Glândulas Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias das Paratireoides/complicações , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
3.
Ultrasound Med Biol ; 42(6): 1273-81, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26976785

RESUMO

This prospective study evaluates the accuracy of virtual touch imaging quantification (VTIQ), a non-invasive shear wave elastography method for measuring cervical lymph nodes (LN) stiffness in differentiating benign from malignant LN. The study evaluated 270 LN in 236 patients with both conventional B-mode ultrasound and VTIQ shear wave elastography before fine-needle aspiration biopsy (FNAB). LN stiffness was measured as shear wave velocity (SWV) in m/s. Surgical resection was advised for FNAB results that were not clearly benign. Surgical pathology confirmed 54 malignant LN. The receiver operating curve (ROC) identified a single cut-off value of 2.93 m/s as the maximum SWV for predicting a malignant cervical LN. The sensitivity and specificity were 92.59% and 75.46%, respectively. Positive predictive value (PPV) was 48.54% and negative predictive value (NPV) was 97.60%. LN stiffness measured by VTIQ-generated shear wave elastography is an independent predictor of malignancy.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias da Glândula Tireoide/patologia , Diagnóstico Diferencial , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Pescoço , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Ultrasound Med Biol ; 41(11): 2855-65, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26277203

RESUMO

This study determines the performance of virtual touch imaging quantification (VTIQ), a non-invasive shear wave elastography method for measuring thyroid nodule (TN) stiffness, in distinguishing benign from malignant TNs. This prospective study evaluates 707 TNs in 676 patients with fine-needle aspiration biopsy (FNAB). Before FNAB, both conventional B-mode ultrasound and shear wave elastography were performed. Surgical resection was recommended for FNAB results that were not clearly benign. Surgical pathology confirmed 82 malignant TNs. The receiver operating curve identified a single cut-off of 3.54 m/s as the maximum shear wave velocity (SWV) for predicting thyroid cancer (TC). The sensitivity and specificity were 79.27% and 71.52%, respectively. Positive predictive value (PPV) was 26.75% and negative predictive value (NPV) was 96.34%. Compared with B-mode US features for predicting malignancy, SWV ≥3.54 m/s has a higher sensitivity, specificity, PPV and NPV. TN stiffness measured by VTIQ-generated shear wave elastography is an independent predictor of TC.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adolescente , Adulto , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Glândula Tireoide/diagnóstico por imagem , Adulto Jovem