Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Med Phys ; 8(5): 629-39, 1981.
Artigo em Inglês | MEDLINE | ID: mdl-7290015

RESUMO

Theoretical and experimental techniques have been used to study optimal x-ray for screen-film mammography. A simple model of mammographic imaging predicts optimum x-ray energies which are significantly higher than the K-characteristic energies of Mo. A subjective comparison of x-ray spectra from Mo-anode and W-anode tubes indicates that spectra produced by a W-anode tube filtered with materials of atomic number just above that of Mo are more suitable for screen-film mammography than spectra produced by the Mo-anode/Mo-filter system. The imaging performance of K-edge filtered, W-anode tube spectra was compared to the performance of Mo-anode spectra using phantom measurements and mastectomy specimen radiography. It was shown that optimal W-anode spectra can produce equal contrast with an exposure reduction of a factor of two to three, a dose reduction of a factor of two, and equal or reducing tube loading, compared to Mo-anode spectra. A computer simulation was carried out to extend the initial, monoenergetic theory to the case of real, polychromatic sources. The effects of varying filter material and thickness, tube operating potential, and breast thickness were all studied. Since W-anode x-ray tubes are considered to be better for Xerox mammography than Mo-anode tubes, this study has shown that both Xerox and screen-film techniques can be performed optimally with a single, properly designed, W-anode x-ray tube.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Intensificação de Imagem Radiográfica , Ecrans Intensificadores para Raios X , Computadores , Feminino , Humanos , Mamografia/instrumentação , Modelos Teóricos , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Análise Espectral
3.
Radiology ; 132(3): 744-6, 1979 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-224414

RESUMO

A simple technique is described for producing enhanced radiographs of excised breast specimens with clinical mammographic equipment. Radiographs of specimens immersed in water are compared to radiographs of the same specimen in air. Using this fluid-balancing technique, visualization of tissue structure is enhanced, particularly when negative-mode Xerox or film is used.


Assuntos
Adenocarcinoma Esquirroso/patologia , Neoplasias da Mama/patologia , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Adenocarcinoma Esquirroso/diagnóstico por imagem , Ar , Neoplasias da Mama/diagnóstico por imagem , Feminino , Técnicas Histológicas , Humanos , Água , Xerorradiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...