Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acad Emerg Med ; 7(6): 611-7, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10905639

RESUMO

OBJECTIVE: To determine whether the alveolar dead space volume (V(D)alv), expressed as a percentage of the alveolar tidal volume (V(D)alv/V(T)alv), can predict the degree of vascular occlusion caused by pulmonary embolism (PE). METHODS: Fifty-three subjects with suspected PE were prospectively studied. Pulmonary embolism was diagnosed in 33 by high-probability ventilation/perfusion (V/Q) scan (n = 19) or by pulmonary arteriography (PAG, n = 14). Pulmonary embolism was excluded by PAG in 20 subjects. The V(D)alv/V(T)alv was determined from volumetric capnography and arterial blood gas analysis, which permits measurement of the physiologic dead space, V(D)phys (mL) = [(PaCO2 - PeCO2)/PaCO2]. tidal volume. Airway dead space (V(D)aw) was subtracted to yield the alveolar dead space [(V(D)phys - V(D)aw) = V(D)alv (mL)]; the percentage of alveolar volume occupied by alveolar dead space per breath = V(D)alv/V(T)alv x 100%. Percentage perfusion defect was determined from V/Q scans by a radiologist blinded to other data. Regression analysis was performed to show correlation between V(D)alv/V(T)alv and defect on V/Q scan or systolic pulmonary arterial pressure (SPAP). RESULTS: For subjects with PE, the mean perfusion defect on lung scan was 38 +/- 22%; the mean V(D)alv = 208 +/- 115 mL, V(T)alv = 452 +/- 251 mL, and V(D)alv/V(T)alv = 43 +/- 18%. Regression of V(D)alv/V(T)alv vs perfusion defect yielded r2 = 0.41. Regression of V(D)alv/V(T)alv vs pulmonary artery pressures yielded r2 = 0.59. For subjects without PE, V(D)alv/V(T)alv = 27 +/- 14% and V(D)alv = 89 +/- 66 mL. CONCLUSIONS: The V(D)alv/V(T)alv correlates with the lung perfusion defect and the pulmonary artery pressures in subjects with PE. These findings show the potential for V(D)alv/V(T)alv to quantify the embolic burden of PE.


Assuntos
Embolia Pulmonar/diagnóstico , Espaço Morto Respiratório , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Alvéolos Pulmonares/fisiopatologia , Embolia Pulmonar/mortalidade , Embolia Pulmonar/fisiopatologia , Troca Gasosa Pulmonar , Análise de Regressão , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Taxa de Sobrevida , Relação Ventilação-Perfusão
2.
Ann Surg ; 227(5): 764-9; discussion 769-71, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9605668

RESUMO

OBJECTIVE: The purpose of this study was to determine the sensitivity, specificity, and clinical utility of 18F 2-fluoro-2-deoxy-D-glucose (FDG) total-body positron emission tomography (PET) scanning for the detection of metastases in patients with malignant melanoma. SUMMARY BACKGROUND DATA: Recent preliminary reports suggest that PET using FDG may be more sensitive and specific for detection of metastatic melanoma than standard radiologic imaging studies using computed tomography (CT). PET technology is showing utility in the detection of metastatic tumors from multiple primary sites including breast, lung, lymphoma, and melanoma. However, little information is available concerning the general utility, sensitivity, and specificity of PET scanning of patients with metastatic melanoma. METHODS: One hundred three PET scans done on 76 nonrandomized patients having AJCC stage II to IV melanoma were prospectively evaluated. Patients were derived from two groups. Group 1 (63 patients) had PET, CT (chest and abdomen), and magnetic resonance imaging (MRI; brain) scans as a part of staging requirements for immunotherapy protocols. Group 2 (13 nonprotocol patients) had PET, CT, and MRI scans as in group 1, but for clinical evaluation only. PET scans were done using 12 to 20 mCi of FDG given intravenously. Results of PET scans were compared to CT scans and biopsy or cytology results. RESULTS: PET scanning for the detection of melanoma metastases had a sensitivity of 94.2% and a specificity of 83.3% compared to 55.3% and 84.4%, respectively, for CT scanning. Factors that produced false-positive PET scans were papillary carcinoma of the thyroid (1), bronchogenic carcinoma (1), inflamed epidermal cyst (1), Warthin's tumor of the parotid gland (1), surgical wound inflammation (2), leiomyoma of the uterus (1), suture granuloma (1), and endometriosis (1). The four false-negative scans were thought to be due to smaller (<0.3 to 0.5 cm) and diffuse areas of melanoma without a mass effect. CONCLUSIONS: PET scanning is extremely sensitive (94.2%) and very specific (83.3%) for identifying metastatic melanoma, particularly in soft tissues, lymph nodes, and the liver. A number of second primary or metastatic tumors and an inflammatory response can also be localized by PET. This observation mandates a close clinical correlation with positive PET and emphasizes the importance of establishing a tissue diagnosis. False-negative scans in the presence of metastases are rare (4% of scans). Metastases < or =5 mm in diameter may not image well. PET is superior to CT in detecting melanoma metastases and has a role as a primary strategy in the staging of melanoma.


Assuntos
Fluordesoxiglucose F18 , Melanoma/diagnóstico por imagem , Melanoma/secundário , Compostos Radiofarmacêuticos , Neoplasias Cutâneas/patologia , Tomografia Computadorizada de Emissão , Erros de Diagnóstico , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade
3.
J Vasc Surg ; 5(6): 833-7, 1987 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2953910

RESUMO

A study was designed to compare platelet deposition between knitted and woven Dacron grafts in the same patient. Twenty patients received aortoiliac or aortofemoral bifurcated Dacron grafts, each composed of one woven and one double-velour knitted limb. External nuclear graft imaging was carried out after injection of autologous platelets labeled with indium 111. The patients were studied postoperatively in time periods ranging from 6 days to 42 months. Platelet accumulation was almost identical in knitted and woven limbs in all patients. This study appears to indicate that there is no difference in thrombogenicity between knitted and woven bifurcated Dacron grafts in the aortoiliac or aortofemoral positions measured by platelet accumulation.


Assuntos
Aorta Abdominal/cirurgia , Plaquetas/diagnóstico por imagem , Prótese Vascular , Índio , Adesividade Plaquetária , Radioisótopos , Estudos de Avaliação como Assunto , Artéria Femoral/cirurgia , Humanos , Polietilenotereftalatos , Período Pós-Operatório , Desenho de Prótese , Cintilografia , Fatores de Tempo
4.
N C Med J ; 44(5): 281-4, 1983 May.
Artigo em Inglês | MEDLINE | ID: mdl-6575253
5.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...