Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiother Oncol ; 115(1): 72-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25779722

RESUMO

BACKGROUND AND PURPOSE: To evaluate the reconstruction accuracy of brachytherapy (BT) applicators tips in vitro and in vivo in MRI-guided (192)Ir-high-dose-rate (HDR)-BT of inoperable liver tumors. MATERIALS AND METHODS: Reconstruction accuracy of plastic BT applicators, visualized by nitinol inserts, was assessed in MRI phantom measurements and in MRI (192)Ir-HDR-BT treatment planning datasets of 45 patients employing CT co-registration and vector decomposition. Conspicuity, short-term dislocation, and reconstruction errors were assessed in the clinical data. The clinical effect of applicator reconstruction accuracy was determined in follow-up MRI data. RESULTS: Applicator reconstruction accuracy was 1.6±0.5 mm in the phantom measurements. In the clinical MRI datasets applicator conspicuity was rated good/optimal in ⩾72% of cases. 16/129 applicators showed not time dependent deviation in between MRI/CT acquisition (p>0.1). Reconstruction accuracy was 5.5±2.8 mm, and the average image co-registration error was 3.1±0.9 mm. Vector decomposition revealed no preferred direction of reconstruction errors. In the follow-up data deviation of planned dose distribution and irradiation effect was 6.9±3.3 mm matching the mean co-registration error (6.5±2.5 mm; p>0.1). CONCLUSION: Applicator reconstruction accuracy in vitro conforms to AAPM TG 56 standard. Nitinol-inserts are feasible for applicator visualization and yield good conspicuity in MRI treatment planning data. No preferred direction of reconstruction errors were found in vivo.


Assuntos
Braquiterapia/métodos , Neoplasias Hepáticas/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Radioisótopos de Irídio/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
2.
Comput Math Methods Med ; 2013: 902470, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23690883

RESUMO

For coregistration of medical images, rigid methods often fail to provide enough freedom, while reliable elastic methods are available clinically for special applications only. The number of degrees of freedom of elastic models must be reduced for use in the clinical setting to archive a reliable result. We propose a novel geometry-based method of nonrigid 3D medical image registration and fusion. The proposed method uses a 3D surface-based deformable model as guidance. In our twofold approach, the deformable mesh from one of the images is first applied to the boundary of the object to be registered. Thereafter, the non-rigid volume deformation vector field needed for registration and fusion inside of the region of interest (ROI) described by the active surface is inferred from the displacement of the surface mesh points. The method was validated using clinical images of a quasirigid organ (kidney) and of an elastic organ (liver). The reduction in standard deviation of the image intensity difference between reference image and model was used as a measure of performance. Landmarks placed at vessel bifurcations in the liver were used as a gold standard for evaluating registration results for the elastic liver. Our registration method was compared with affine registration using mutual information applied to the quasi-rigid kidney. The new method achieved 15.11% better quality with a high confidence level of 99% for rigid registration. However, when applied to the quasi-elastic liver, the method has an averaged landmark dislocation of 4.32 mm. In contrast, affine registration of extracted livers yields a significantly (P = 0.000001) smaller dislocation of 3.26 mm. In conclusion, our validation shows that the novel approach is applicable in cases where internal deformation is not crucial, but it has limitations in cases where internal displacement must also be taken into account.


Assuntos
Imageamento Tridimensional/métodos , Algoritmos , Biologia Computacional , Elasticidade/fisiologia , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Rim/anatomia & histologia , Rim/fisiologia , Fígado/anatomia & histologia , Fígado/fisiologia , Modelos Biológicos , Modelos Estatísticos
3.
Rev Sci Instrum ; 80(2): 023103, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19256636

RESUMO

Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers, namely, the thicknesses of dead layer, beryllium window, and crystal active area. The efficiency of three silicon detectors has been precisely investigated in their entire photon energy range of detection. In the zero to a few keV range, we developed a new method based on the detection of the 2E1 decay of the metastable Ar(17+) 2s-->1s transition. Very good theoretical knowledge of the energetic distribution of the 2E1 decay mode enables precise characterization of the absorbing layers in front of the detectors. In the high-energy range (>10 keV), the detector crystal thickness plays a major role in the detection efficiency and has been determined using a (241)Am source.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...