Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Eur J Radiol ; 176: 111529, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38810440

RESUMO

PURPOSE: This study investigated strategies to reduce pneumothorax risk in CT-guided lung biopsy. The approach involved administering 10 ml of 1 % lidocaine fluid in the subpleural or pleural space before lung puncture and utilizing the gravitational effect of pleural pressure with specific patient positioning. METHOD: We retrospectively analyzed 72 percutaneous CT-guided lung biopsies performed at a single center between January 2020 and April 2023. These were grouped based on fluid administration during the biopsy and whether the biopsies were conducted in dependent or non-dependent lung regions. Confounding factors like patient demographics, lesion characteristics, and procedural details were assessed. Patient characteristics and the occurrence of pneumothoraces were compared using a Kurskal-Wallis test for continuous variables and a Fisher's exact test for categorical variables. Multivariable logistic regression was used to identify potential confounders. RESULTS: Subpleural or pleural fluid administration and performing biopsies in dependent lung areas were significantly linked to lower peri-interventional pneumothorax incidence (n = 15; 65 % without fluid in non-dependent areas, n = 5; 42 % without fluid in dependent areas, n = 5; 36 % with fluid in non-dependent areas,n = 0; 0 % with fluid in dependent areas; p = .001). Even after adjusting for various factors, biopsy in dependent areas and fluid administration remained independently associated with reduced pneumothorax risk (OR 0.071, p<=.01 for lesions with fluid administration; OR 0.077, p = .016 for lesions in dependent areas). CONCLUSIONS: Pre-puncture fluid administration to the pleura and consideration of gravitational effects during patient positioning can effectively decrease pneumothorax occurrences in CT-guided lung biopsy.


Assuntos
Biópsia Guiada por Imagem , Pleura , Pneumotórax , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pneumotórax/prevenção & controle , Pneumotórax/etiologia , Biópsia Guiada por Imagem/métodos , Biópsia Guiada por Imagem/efeitos adversos , Estudos Retrospectivos , Pessoa de Meia-Idade , Pleura/patologia , Pleura/diagnóstico por imagem , Idoso , Pulmão/patologia , Pulmão/diagnóstico por imagem , Radiografia Intervencionista/métodos , Gravitação , Lidocaína/administração & dosagem , Posicionamento do Paciente/métodos , Adulto , Pressão , Punções
2.
J Magn Reson Imaging ; 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553860

RESUMO

BACKGROUND: Extracellular volume (ECV) correlates with the degree of liver fibrosis. PURPOSE: To analyze the performance of liver MRI-based ECV evaluations with different blood pool measurements at different time points. STUDY TYPE: Prospective. SAMPLE: 73 consecutive patients (n = 31 females, mean age 56 years) with histopathology-proven liver fibrosis. FIELD STRENGTH/SEQUENCE: 3T acquisition within 90 days of biopsy, including shortened modified look-locker inversion recovery T1 mapping. ASSESSMENT: Polygonal regions of interest were manually drawn in the liver, aorta, vena cava, and in the main, left and right portal vein on four slices before and after Gd-DOTA administration at 5/10/15 minutes. ECV was calculated 1) on one single slice on portal bifurcation level, and 2) averaged over all four slices. STATISTICAL TESTS: Parameters were compared between patients with fibrosis grades F0-2 and F3-F4 with the Mann-Whitney U and fishers exact test. ROC analysis was used to assess the performance of the parameters to predict F3-4 fibrosis. A P-value <0.05 was considered statistically significant. RESULTS: ECV was significantly higher in F3-4 fibrosis (35.4% [33.1%-37.6%], 36.1% [34.2%-37.5%], and 37.0% [34.8%-39.2%] at 5/10/15 minutes) than in patients with F0-2 fibrosis (33.3% [30.8%-34.8%], 33.7% [31.6%-34.7%] and 34.9% [32.2%-36.0%]; AUC = 0.72-0.75). Blood pool T1 relaxation times in the aorta and vena cava were longer on the upper vs. lower slices at 5 minutes, but not at 10/15 minutes. AUC values were similar when measured on a single slice (AUC = 0.69-0.72) or based on blood pool measurements in the cava or portal vein (AUC = 0.63-0.67 and AUC = 0.65-0.70). DATA CONCLUSION: Liver ECV is significantly higher in F3-4 fibrosis compared to F0-2 fibrosis with blood pool measurements performed in the aorta, inferior vena cava, and portal vein at 5, 10, and 15 minutes. However, a smaller variability was observed for blood pool measurements between slices at 15 minutes. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.

3.
Eur Radiol ; 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38546793
4.
Eur Radiol ; 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37870625

RESUMO

OBJECTIVES: The purpose of this study was to determine the influence of dose reduction on a commercially available lung cancer prediction convolutional neuronal network (LCP-CNN). METHODS: CT scans from a cohort provided by the local lung cancer center (n = 218) with confirmed pulmonary malignancies and their corresponding reduced dose simulations (25% and 5% dose) were subjected to the LCP-CNN. The resulting LCP scores (scale 1-10, increasing malignancy risk) and the proportion of correctly classified nodules were compared. The cohort was divided into a low-, medium-, and high-risk group based on the respective LCP scores; shifts between the groups were studied to evaluate the potential impact on nodule management. Two different malignancy risk score thresholds were analyzed: a higher threshold of ≥ 9 ("rule-in" approach) and a lower threshold of > 4 ("rule-out" approach). RESULTS: In total, 169 patients with 196 nodules could be included (mean age ± SD, 64.5 ± 9.2 year; 49% females). Mean LCP scores for original, 25% and 5% dose levels were 8.5 ± 1.7, 8.4 ± 1.7 (p > 0.05 vs. original dose) and 8.2 ± 1.9 (p < 0.05 vs. original dose), respectively. The proportion of correctly classified nodules with the "rule-in" approach decreased with simulated dose reduction from 58.2 to 56.1% (p = 0.34) and to 52.0% for the respective dose levels (p = 0.01). For the "rule-out" approach the respective values were 95.9%, 96.4%, and 94.4% (p = 0.12). When reducing the original dose to 25%/5%, eight/twenty-two nodules shifted to a lower, five/seven nodules to a higher malignancy risk group. CONCLUSION: CT dose reduction may affect the analyzed LCP-CNN regarding the classification of pulmonary malignancies and potentially alter pulmonary nodule management. CLINICAL RELEVANCE STATEMENT: Utilization of a "rule-out" approach with a lower malignancy risk threshold prevents underestimation of the nodule malignancy risk for the analyzed software, especially in high-risk cohorts. KEY POINTS: • LCP-CNN may be affected by CT image parameters such as noise resulting from low-dose CT acquisitions. • CT dose reduction can alter pulmonary nodule management recommendations by affecting the outcome of the LCP-CNN. • Utilization of a lower malignancy risk threshold prevents underestimation of pulmonary malignancies in high-risk cohorts.

5.
Eur J Radiol ; 167: 111047, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37690351

RESUMO

PURPOSE: To evaluate the effectiveness of automated liver segmental volume quantification and calculation of the liver segmental volume ratio (LSVR) on a non-contrast T1-vibe Dixon liver MRI sequence using a deep learning segmentation pipeline. METHOD: A dataset of 200 liver MRI with a non-contrast 3 mm T1-vibe Dixon sequence was manually labeledslice-by-sliceby an expert for Couinaud liver segments, while portal and hepatic veins were labeled separately. A convolutional neural networkwas trainedusing 170 liver MRI for training and 30 for evaluation. Liver segmental volumes without liver vessels were retrieved and LSVR was calculated as the liver segmental volumes I-III divided by the liver segmental volumes IV-VIII. LSVR was compared with the expert manual LSVR calculation and the LSVR calculated on CT scans in 30 patients with CT and MRI within 6 months. RESULTS: Theconvolutional neural networkclassified the Couinaud segments I-VIII with an average Dice score of 0.770 ± 0.03, ranging between 0.726 ± 0.13 (segment IVb) and 0.810 ± 0.09 (segment V). The calculated mean LSVR with liver MRI unseen by the model was 0.32 ± 0.14, as compared with manually quantified LSVR of 0.33 ± 0.15, resulting in a mean absolute error (MAE) of 0.02. A comparable LSVR of 0.35 ± 0.14 with a MAE of 0.04 resulted with the LSRV retrieved from the CT scans. The automated LSVR showed significant correlation with the manual MRI LSVR (Spearman r = 0.97, p < 0.001) and CT LSVR (Spearman r = 0.95, p < 0.001). CONCLUSIONS: A convolutional neural network allowed for accurate automated liver segmental volume quantification and calculation of LSVR based on a non-contrast T1-vibe Dixon sequence.


Assuntos
Aprendizado Profundo , Humanos , Fígado/diagnóstico por imagem , Radiografia , Cintilografia , Imageamento por Ressonância Magnética
6.
Eur Phys J Plus ; 138(5): 391, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37192839

RESUMO

Medical imaging has been intensively employed in screening, diagnosis and monitoring during the COVID-19 pandemic. With the improvement of RT-PCR and rapid inspection technologies, the diagnostic references have shifted. Current recommendations tend to limit the application of medical imaging in the acute setting. Nevertheless, efficient and complementary values of medical imaging have been recognized at the beginning of the pandemic when facing unknown infectious diseases and a lack of sufficient diagnostic tools. Optimizing medical imaging for pandemics may still have encouraging implications for future public health, especially for long-lasting post-COVID-19 syndrome theranostics. A critical concern for the application of medical imaging is the increased radiation burden, particularly when medical imaging is used for screening and rapid containment purposes. Emerging artificial intelligence (AI) technology provides the opportunity to reduce the radiation burden while maintaining diagnostic quality. This review summarizes the current AI research on dose reduction for medical imaging, and the retrospective identification of their potential in COVID-19 may still have positive implications for future public health.

7.
Invest Radiol ; 58(8): 602-609, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37058321

RESUMO

ABSTRACT: Interstitial lung disease (ILD) is now diagnosed by an ILD-board consisting of radiologists, pulmonologists, and pathologists. They discuss the combination of computed tomography (CT) images, pulmonary function tests, demographic information, and histology and then agree on one of the 200 ILD diagnoses. Recent approaches employ computer-aided diagnostic tools to improve detection of disease, monitoring, and accurate prognostication. Methods based on artificial intelligence (AI) may be used in computational medicine, especially in image-based specialties such as radiology. This review summarises and highlights the strengths and weaknesses of the latest and most significant published methods that could lead to a holistic system for ILD diagnosis. We explore current AI methods and the data use to predict the prognosis and progression of ILDs. It is then essential to highlight the data that holds the most information related to risk factors for progression, e.g., CT scans and pulmonary function tests. This review aims to identify potential gaps, highlight areas that require further research, and identify the methods that could be combined to yield more promising results in future studies.


Assuntos
Inteligência Artificial , Doenças Pulmonares Intersticiais , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Prognóstico , Tomografia Computadorizada por Raios X/métodos , Radiologistas , Pulmão/diagnóstico por imagem
8.
Eur Radiol ; 33(8): 5568-5577, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36894752

RESUMO

OBJECTIVES: To evaluate and compare the measurement accuracy of two different computer-aided diagnosis (CAD) systems regarding artificial pulmonary nodules and assess the clinical impact of volumetric inaccuracies in a phantom study. METHODS: In this phantom study, 59 different phantom arrangements with 326 artificial nodules (178 solid, 148 ground-glass) were scanned at 80 kV, 100 kV, and 120 kV. Four different nodule diameters were used: 5 mm, 8 mm, 10 mm, and 12 mm. Scans were analyzed by a deep-learning (DL)-based CAD and a standard CAD system. Relative volumetric errors (RVE) of each system vs. ground truth and the relative volume difference (RVD) DL-based vs. standard CAD were calculated. The Bland-Altman method was used to define the limits of agreement (LOA). The hypothetical impact on LungRADS classification was assessed for both systems. RESULTS: There was no difference between the three voltage groups regarding nodule volumetry. Regarding the solid nodules, the RVE of the 5-mm-, 8-mm-, 10-mm-, and 12-mm-size groups for the DL CAD/standard CAD were 12.2/2.8%, 1.3/ - 2.8%, - 3.6/1.5%, and - 12.2/ - 0.3%, respectively. The corresponding values for the ground-glass nodules (GGN) were 25.6%/81.0%, 9.0%/28.0%, 7.6/20.6%, and 6.8/21.2%. The mean RVD for solid nodules/GGN was 1.3/ - 15.2%. Regarding the LungRADS classification, 88.5% and 79.8% of all solid nodules were correctly assigned by the DL CAD and the standard CAD, respectively. 14.9% of the nodules were assigned differently between the systems. CONCLUSIONS: Patient management may be affected by the volumetric inaccuracy of the CAD systems and hence demands supervision and/or manual correction by a radiologist. KEY POINTS: • The DL-based CAD system was more accurate in the volumetry of GGN and less accurate regarding solid nodules than the standard CAD system. • Nodule size and attenuation have an effect on the measurement accuracy of both systems; tube voltage has no effect on measurement accuracy. • Measurement inaccuracies of CAD systems can have an impact on patient management, which demands supervision by radiologists.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Tomografia Computadorizada por Raios X/métodos , Diagnóstico por Computador/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Imagens de Fantasmas , Radiologistas , Neoplasias Pulmonares/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade
10.
Int J Cardiovasc Imaging ; 39(1): 135-144, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36598693

RESUMO

The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Cicatriz , Água , Estudos Retrospectivos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Aumento da Imagem/métodos
11.
Eur Radiol ; 33(6): 3908-3917, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36538071

RESUMO

OBJECTIVES: To assess the value of quantitative computed tomography (QCT) of the whole lung and nodule-bearing lobe regarding pulmonary nodule malignancy risk estimation. METHODS: A total of 251 subjects (median [IQR] age, 65 (57-73) years; 37% females) with pulmonary nodules on non-enhanced thin-section CT were retrospectively included. Twenty percent of the nodules were malignant, the remainder benign either histologically or at least 1-year follow-up. CT scans were subjected to in-house software, computing parameters such as mean lung density (MLD) or peripheral emphysema index (pEI). QCT variable selection was performed using logistic regression; selected variables were integrated into the Mayo Clinic and the parsimonious Brock Model. RESULTS: Whole-lung analysis revealed differences between benign vs. malignant nodule groups in several parameters, e.g. the MLD (-766 vs. -790 HU) or the pEI (40.1 vs. 44.7 %). The proposed QCT model had an area-under-the-curve (AUC) of 0.69 (95%-CI, 0.62-0.76) based on all available data. After integrating MLD and pEI into the Mayo Clinic and Brock Model, the AUC of both clinical models improved (AUC, 0.91 to 0.93 and 0.88 to 0.91, respectively). The lobe-specific analysis revealed that the nodule-bearing lobes had less emphysema than the rest of the lung regarding benign (EI, 0.5 vs. 0.7 %; p < 0.001) and malignant nodules (EI, 1.2 vs. 1.7 %; p = 0.001). CONCLUSIONS: Nodules in subjects with higher whole-lung metrics of emphysema and less fibrosis are more likely to be malignant; hereby the nodule-bearing lobes have less emphysema. QCT variables could improve the risk assessment of incidental pulmonary nodules. KEY POINTS: • Nodules in subjects with higher whole-lung metrics of emphysema and less fibrosis are more likely to be malignant. • The nodule-bearing lobes have less emphysema compared to the rest of the lung. • QCT variables could improve the risk assessment of incidental pulmonary nodules.


Assuntos
Enfisema , Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Enfisema Pulmonar , Nódulo Pulmonar Solitário , Feminino , Humanos , Idoso , Masculino , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/patologia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/patologia , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Fibrose
12.
Respiration ; 102(2): 120-133, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36566741

RESUMO

BACKGROUND: Lung function impairment persists in some patients for months after acute coronavirus disease 2019 (COVID-19). Long-term lung function, radiological features, and their association remain to be clarified. OBJECTIVES: We aimed to prospectively investigate lung function and radiological abnormalities over 12 months after severe and non-severe COVID-19. METHODS: 584 patients were included in the Swiss COVID-19 lung study. We assessed lung function at 3, 6, and 12 months after acute COVID-19 and compared chest computed tomography (CT) imaging to lung functional abnormalities. RESULTS: At 12 months, diffusion capacity for carbon monoxide (DLCOcorr) was lower after severe COVID-19 compared to non-severe COVID-19 (74.9% vs. 85.2% predicted, p < 0.001). Similarly, minimal oxygen saturation on 6-min walk test and total lung capacity were lower after severe COVID-19 (89.6% vs. 92.2%, p = 0.004, respectively, 88.2% vs. 95.1% predicted, p = 0.011). The difference for forced vital capacity (91.6% vs. 96.3% predicted, p = 0.082) was not statistically significant. Between 3 and 12 months, lung function improved in both groups and differences in DLCO between non-severe and severe COVID-19 patients decreased. In patients with chest CT scans at 12 months, we observed a correlation between radiological abnormalities and reduced lung function. While the overall extent of radiological abnormalities diminished over time, the frequency of mosaic attenuation and curvilinear patterns increased. CONCLUSIONS: In this prospective cohort study, patients who had severe COVID-19 had diminished lung function over the first year compared to those after non-severe COVID-19, albeit with a greater extent of recovery in the severe disease group.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Estudos Prospectivos , Suíça/epidemiologia , Pulmão/diagnóstico por imagem
13.
Rofo ; 195(1): 47-54, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36067777

RESUMO

Despite current recommendations, there is no recent scientific study comparing the influence of CT reconstruction kernels on lung pattern recognition in interstitial lung disease (ILD).To evaluate the sensitivity of lung (i70) and soft (i30) CT kernel algorithms for the diagnosis of ILD patterns.We retrospectively extracted between 15-25 pattern annotations per case (1 annotation = 15 slices of 1 mm) from 23 subjects resulting in 408 annotation stacks per lung kernel and soft kernel reconstructions. Two subspecialized chest radiologists defined the ground truth in consensus. 4 residents, 2 fellows, and 2 general consultants in radiology with 3 to 13 years of experience in chest imaging performed a blinded readout. In order to account for data clustering, a generalized linear mixed model (GLMM) with random intercept for reader and nested for patient and image and a kernel/experience interaction term was used to analyze the results.The results of the GLMM indicated, that the odds of correct pattern recognition is 12 % lower with lung kernel compared to soft kernel; however, this was not statistically significant (OR 0.88; 95%-CI, 0.73-1.06; p = 0.187). Furthermore, the consultants' odds of correct pattern recognition was 78 % higher than the residents' odds, although this finding did not reach statistical significance either (OR 1.78; 95%-CI, 0.62-5.06; p = 0.283). There was no significant interaction between the two fixed terms kernel and experience. Intra-rater agreement between lung and soft kernel was substantial (κ = 0.63 ±â€Š0.19). The mean inter-rater agreement for lung/soft kernel was κ = 0.37 ±â€Š0.17/κ = 0.38 ±â€Š0.17.There is no significant difference between lung and soft kernel reconstructed CT images for the correct pattern recognition in ILD. There are non-significant trends indicating that the use of soft kernels and a higher level of experience lead to a higher probability of correct pattern identification. · There is no significant difference between lung and soft kernel reconstructed CT images for the correct pattern recognition in interstitial lung disease.. · There are even non-significant tendencies that the use of soft kernels lead to a higher probability of correct pattern identification.. · These results challenge the current recommendations and the routinely performed separate lung kernel reconstructions for lung parenchyma analysis.. CITATION FORMAT: · Klaus JB, Christodoulidis S, Peters AA et al. Influence of Lung Reconstruction Algorithms on Interstitial Lung Pattern Recognition on CT. Fortschr Röntgenstr 2023; 195: 47 - 54.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Algoritmos
14.
Sci Rep ; 12(1): 22059, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36543852

RESUMO

We evaluated the effectiveness of automated segmentation of the liver and its vessels with a convolutional neural network on non-contrast T1 vibe Dixon acquisitions. A dataset of non-contrast T1 vibe Dixon liver magnetic resonance images was labelled slice-by-slice for the outer liver border, portal, and hepatic veins by an expert. A 3D U-Net convolutional neural network was trained with different combinations of Dixon in-phase, opposed-phase, water, and fat reconstructions. The neural network trained with the single-modal in-phase reconstructions achieved a high performance for liver parenchyma (Dice 0.936 ± 0.02), portal veins (0.634 ± 0.09), and hepatic veins (0.532 ± 0.12) segmentation. No benefit of using multi-modal input was observed (p = 1.0 for all experiments), combining in-phase, opposed-phase, fat, and water reconstruction. Accuracy for differentiation between portal and hepatic veins was 99% for portal veins and 97% for hepatic veins in the central region and slightly lower in the peripheral region (91% for portal veins, 80% for hepatic veins). In conclusion, deep learning-based automated segmentation of the liver and its vessels on non-contrast T1 vibe Dixon was highly effective. The single-modal in-phase input achieved the best performance in segmentation and differentiation between portal and hepatic veins.


Assuntos
Fígado , Redes Neurais de Computação , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Veia Porta/diagnóstico por imagem , Água , Processamento de Imagem Assistida por Computador/métodos
15.
Biomedicines ; 10(6)2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35740322

RESUMO

Background: Vascular abnormalities, including venous congestion (VC) and pulmonary embolism (PE), have been recognized as frequent COVID-19 imaging patterns and proposed as severity markers. However, the underlying pathophysiological mechanisms remain unclear. In this study, we aimed to characterize the relationship between VC, PE distribution, and alveolar opacities (AO). Methods: This multicenter observational registry (clinicaltrials.gov identifier NCT04824313) included 268 patients diagnosed with SARS-CoV-2 infection and subjected to contrast-enhanced CT between March and June 2020. Acute PE was diagnosed in 61 (22.8%) patients, including 17 females (27.9%), at a mean age of 61.7 ± 14.2 years. Demographic, laboratory, and outcome data were retrieved. We analyzed CT images at the segmental level regarding VC (qualitatively and quantitatively [diameter]), AO (semi-quantitatively as absent, <50%, or >50% involvement), clot location, and distribution related to VC and AO. Segments with vs. without PE were compared. Results: Out of 411 emboli, 82 (20%) were lobar or more proximal and 329 (80%) were segmental or subsegmental. Venous diameters were significantly higher in segments with AO (p = 0.031), unlike arteries (p = 0.138). At the segmental level, 77% of emboli were associated with VC. Overall, PE occurred in 28.2% of segments with AO vs. 21.8% without (p = 0.047). In the absence of VC, however, AO did not affect PE rates (p = 0.94). Conclusions: Vascular changes predominantly affected veins, and most PEs were located in segments with VC. In the absence of VC, AOs were not associated with the PE rate. VC might result from increased flow supported by the hypothesis of pulmonary arteriovenous anastomosis dysregulation as a relevant contributing factor.

16.
Swiss Med Wkly ; 152(15-16)2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35633633

RESUMO

BACKGROUND: Lung cancer is the leading cause of cancer-related deaths in Switzerland. Despite this, there is no lung cancer screening program in the country. In the United States, low-dose computed tomography (LDCT) lung cancer screening is partially established and endorsed by guidelines. Moreover, evidence is growing that screening reduces lung cancer-related mortality and this was recently shown in a large European randomized controlled trial. Implementation of a lung cancer screening program, however, is challenging and depends on many country-specific factors. The goal of this article is to outline a potential Swiss lung cancer screening program. FRAMEWORK: An exhaustive literature review on international screening models as well as interviews and site visits with international experts were initiated. Furthermore, workshops and interviews with national experts and stakeholders were conducted to share experiences and to establish the basis for a national Swiss lung cancer screening program. SCREENING APPROACH: General practitioners, pulmonologists and the media should be part of the recruitment process. Decentralisation of the screening might lead to a higher adherence rate. To reduce stigmatisation, the screening should be integrated in a "lung health check". Standardisation and a common quality level are mandatory. The PLCOm2012 risk calculation model with a threshold of 1.5% risk for developing cancer in the next six years should be used in addition to established inclusion criteria. Biennial screening is preferred. LUNG RADS and NELSON+ are applied as classification models for lung nodules. CONCLUSION: Based on data from recent studies, literature research, a health technology assessment, the information gained from this project and a pilot study the Swiss Interest Group for lung cancer screening (CH-LSIG) recommends the timely introduction of a systematic lung cancer screening program in Switzerland. The final decision is for the Swiss Cancer Screening Committee to make.


Assuntos
Detecção Precoce de Câncer , Neoplasias Pulmonares , Detecção Precoce de Câncer/métodos , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Projetos Piloto , Suíça , Tomografia Computadorizada por Raios X/métodos
17.
J Vasc Interv Radiol ; 33(4): 416-419.e2, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35365284

RESUMO

The purpose of this study was to define relevant intercostal artery (ICA) anatomy potentially impacting the safety of thoracic percutaneous interventional procedures. An ICA abutting the upper rib and running in the subcostal groove was defined as the lowest risk zone for interventions requiring a supracostal needle puncture. A theoretical high-risk zone was defined by the ICA coursing in the lower half of the intercostal space (ICS), and a theoretical moderate-risk zone was defined by the ICA coursing below the subcostal groove but in the upper half of the ICS. Arterial phase computed tomography data from 250 patients were analyzed, revealing demographic variability, with high-risk zones extending more laterally with advancing age and with more cranial ribs. Overall, within the 97.5th percentile, an ICS puncture >7-cm lateral to the spinous process incurs moderate risk and >10-cm lateral incurs the lowest risk.


Assuntos
Costelas , Parede Torácica , Artérias/anatomia & histologia , Artérias/diagnóstico por imagem , Humanos , Punções , Costelas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
18.
Radiology ; 304(1): 195-204, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35380498

RESUMO

Background Evidence regarding short-term effects of electronic nicotine delivery systems (ENDS) and tobacco smoke on lung ventilation and perfusion is limited. Purpose To examine the immediate effect of ENDS exposure and tobacco smoke on lung ventilation and perfusion by functional MRI and lung function tests. Materials and Methods This prospective observational pilot study was conducted from November 2019 to September 2021 (substudy of randomized controlled trial NCT03589989). Included were 44 healthy adult participants (10 control participants, nine former tobacco smokers, 13 ENDS users, and 12 active tobacco smokers; mean age, 41 years ± 12 [SD]; 28 men) who underwent noncontrast-enhanced matrix pencil MRI and lung function tests before and immediately after the exposure to ENDS products or tobacco smoke. Baseline measurements were acquired after 2 hours of substance abstinence. Postexposure measurements were performed immediately after the exposure. MRI showed semiquantitative measured impairment of lung perfusion (RQ) and fractional ventilation (RFV) impairment as percentages of affected lung volume. Lung clearance index (LCI) was assessed by nitrogen multiple-breath washout to capture ventilation inhomogeneity and spirometry to assess airflow limitation. Absolute differences were calculated with paired Wilcoxon signed-rank test and differences between groups with unpaired Mann-Whitney test. Healthy control participants underwent two consecutive MRI measurements to assess MRI reproducibility. Results MRI was performed and lung function measurement was acquired in tobacco smokers and ENDS users before and after exposure. MRI showed a decrease of perfusion after exposure (RQ, 8.6% [IQR, 7.2%-10.0%] to 9.1% [IQR, 7.8%-10.7%]; P = .03) and no systematic change in RFV (P = .31) among tobacco smokers. Perfusion increased in participants who used ENDS after exposure (RQ, 9.7% [IQR, 7.1%-10.9%] to 9.0% [IQR, 6.9%-10.0%]; P = .01). RFV did not change (P = .38). Only in tobacco smokers was LCI elevated after smoking (P = .02). Spirometry indexes did not change in any participants. Conclusion MRI showed a decrease of lung perfusion after exposure to tobacco smoke and an increase of lung perfusion after use of electronic nicotine delivery systems. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kligerman in this issue.


Assuntos
Poluição por Fumaça de Tabaco , Vaping , Adulto , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Fumar/efeitos adversos , Vaping/efeitos adversos
19.
Sci Rep ; 12(1): 4716, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35304554

RESUMO

Magnetic resonance T1 mapping before and after Gd-EOB-DTPA administration allows quantification of the T1 reduction rate as a non-invasive surrogate marker of liver function. A major limitation of T1 relaxation time measurement is its dependency on MRI field strengths. Since T1 reduction rate is calculated as the relative shortening of T1 relaxation time before and after contrast administration, we hypothesized that the T1 reduction rate is comparable between 1.5 and 3 T. We thus compared liver T1 relaxation times between 1.5 and 3 T in a total of 243 consecutive patients (124, 1.5 T and 119, 3 T) between 09/2018 and 07/2019. T1 reduction rates were compared between patients with no cirrhosis and patients with cirrhosis Child-Pugh A-C. There was no significant difference of T1 reduction rate between 1.5 and 3 T in any patient group (p-value 0.126-0.861). On both 1.5 T and 3 T, T1 reduction rate allowed to differentiate between patients with no cirrhosis and patients with liver cirrhosis Child A-C (p < 0.001). T1 reduction rate showed a good performance to predict liver cirrhosis Child A (AUC = 0.83, p < 0.001), Child B (AUC = 0.83, p < 0.001) and Child C (AUC = 0.92, p < 0.001). In conclusion, T1 reduction rate allows to determine liver function on Gd-EOB-DTPA MRI with comparable values on 1.5 T and 3 T.


Assuntos
Meios de Contraste , Gadolínio DTPA , Humanos , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética
20.
Eur Radiol ; 32(6): 4324-4332, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35059804

RESUMO

OBJECTIVES: This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario. METHODS: Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location. RESULTS: The combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 ± 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence. CONCLUSIONS: The optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition. KEY POINTS: • Modification of tube voltage and tube current has a significant impact on the performance of deep learning-based CAD software. • Nodule size and composition have no significant impact on the software's performance. • The optimal tube voltage/current combination for the examined software is 80 kV/50 mAs.


Assuntos
Aprendizado Profundo , Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Algoritmos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS