Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Prog Orthod ; 25(1): 28, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38910180

RESUMO

INTRODUCTION: Determining the right time for orthodontic treatment is one of the most important factors affecting the treatment plan and its outcome. The aim of this study is to estimate the mandibular growth stage based on cervical vertebral maturation (CVM) in lateral cephalometric radiographs using artificial intelligence. Unlike previous studies, which use conventional CVM stage naming, our proposed method directly correlates cervical vertebrae with mandibular growth slope. METHODS AND MATERIALS: To conduct this study, first, information of people achieved in American Association of Orthodontics Foundation (AAOF) growth centers was assessed and after considering the entry and exit criteria, a total of 200 people, 108 women and 92 men, were included in the study. Then, the length of the mandible in the lateral cephalometric radiographs that were taken serially from the patients was calculated. The corresponding graphs were labeled based on the growth rate of the mandible in 3 stages; before the growth peak of puberty (pre-pubertal), during the growth peak of puberty (pubertal) and after the growth peak of puberty (post-pubertal). A total of 663 images were selected for evaluation using artificial intelligence. These images were evaluated with different deep learning-based artificial intelligence models considering the diagnostic measures of sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). We also employed weighted kappa statistics. RESULTS: In the diagnosis of pre-pubertal stage, the convolutional neural network (CNN) designed for this study has the higher sensitivity and NPV (0.84, 0.91 respectively) compared to ResNet-18 model. The ResNet-18 model had better performance in other diagnostic measures of the pre-pubertal stage and all measures in the pubertal and post-pubertal stages. The highest overall diagnostic accuracy was also obtained using ResNet-18 model with the amount of 87.5% compared to 81% in designed CNN. CONCLUSION: The artificial intelligence model trained in this study can receive images of cervical vertebrae and predict mandibular growth status by classifying it into one of three groups; before the growth spurt (pre-pubertal), during the growth spurt (pubertal), and after the growth spurt (post-pubertal). The highest accuracy is in post-pubertal stage with the designed networks.


Assuntos
Inteligência Artificial , Cefalometria , Vértebras Cervicais , Mandíbula , Humanos , Cefalometria/métodos , Mandíbula/crescimento & desenvolvimento , Mandíbula/diagnóstico por imagem , Masculino , Feminino , Vértebras Cervicais/crescimento & desenvolvimento , Vértebras Cervicais/diagnóstico por imagem , Criança , Adolescente , Puberdade/fisiologia , Aprendizado Profundo
2.
Front Dent ; 21: 10, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38742224

RESUMO

Objectives: The reduction of resistance to sliding between the archwire and bracket promotes more seamless tooth movement, leading to a faster and improved orthodontic treatment experience. This research aimed to examine how the degradation of elastomeric modules, different ligation methods, bracket-wire angle, and wire type (nickel titanium, NiTi or stainless-steel, SS) impact the kinetic friction resulting from the interaction between NiTi or SS archwires and SS brackets. Materials and Methods: The current in vitro study was conducted on nine groups, including NiTi and SS archwires with three types of ligations (O-ring, figure of 8, and SS wire ligature) and two bracket-wire angles (0˚ and 10˚). The kinetic friction in each group was measured using a Universal Testing Machine at four time intervals: baseline, day one, week one, and week four. Repeated measures ANOVA, Mauchly test of sphericity followed by the Greenhouse-Geisser test, and relevant post hoc tests were used for statistical analysis (P<0.05). Results: The authors found a decrease in kinetic friction in all types of ligations, which confirmed the effect of time on the degradation of ligation modules. The kinetic friction of figure of 8 ligations was higher than both O-ring and SS wire ligations. No difference was observed between O-ring and SS wire ligations. Furthermore, the bracket-wire angle did not affect friction. Conclusion: The authors suggest that the use of figure of 8 ligations in NiTi and SS wires should be limited due to their high friction and replaced with other types of ligations, if possible.

3.
BMC Oral Health ; 21(1): 258, 2021 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-33985492

RESUMO

BACKGROUND: Photobiomodulation is widely being used to improve the wound healing process in dentistry and a vast majority of studies have proven its benefits. But there are plenty of knowledge gaps according to the optimal laser characteristics which should be used to maximize the healing effects of lasers. The goal of this systematic review and meta-analysis was to determine the effect of photobiomodulation (PBM) as an adjunctive treatment to periodontal therapies to evaluate secondary intention gingival wound healing and post-operative pain. METHODS: Five databases (PubMed, Embase, Scopus, ProQuest, and Web of Sciences) were searched up to November 30, 2020, for clinical trials that reported the result of the application of PBM on secondary gingival healing wounds and post-operative pain and discomfort after periodontal surgeries. Two independent reviewers selected the eligible studies and the outcomes of interest were extracted. The quality of eligible studies was assessed using the Cochrane Handbook for Systematic Reviews of Interventions. RESULTS: Ultimately, twelve studies were included in this review. The application of PBM as an adjunct to periodontal surgeries resulted in a significant improvement in wound healing indices. The Landry wound healing index at the 7th post-operative day was significantly improved (SMD = 1.044 [95% CI 0.62-1.46]; p < 0.01) in PBM + surgery groups compared to the control groups. There was also a statistically significant increase in the complete wound epithelialization (RR = 3.23 [95% CI 1.66-6.31]; p < 0.01) at the 14th post-operative day compared to the control groups. The methods used to assess the post-operative pain were heterogeneous, and therefore the results were limited which made the meta-analysis for post-operative pain assessment not possible. CONCLUSION: Based on the results of this review, PBM can be effectively used as a method to improve secondary intention wound healing. High-quality randomized clinical trials, however, are needed in the future to identify the optimal PBM irradiation parameters and the effect of PBM on post-operative pain.


Assuntos
Intenção , Cicatrização , Gengiva , Humanos , Dor Pós-Operatória/terapia
4.
J Adv Periodontol Implant Dent ; 13(1): 15-21, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35919912

RESUMO

Background: This systematic review aimed to determine the effectiveness and outcomes of immediate loading methods for short dental implants. Methods: The authors independently conducted an electronic search in the PubMed, Embase, EBSCO, ProQuest, and Cochrane databases for relevant articles published until November 15, 2020. The references of the included studies were assessed, and a manual search was conducted in Google Scholar and PubMed to find additional relevant studies. Results: Finally, three studies were selected and included in this systematic review. Significant heterogeneity existed in the design of the included studies, and due to the low number of the included studies, the authors could not perform a meta-analysis. The studies showed that the survival rate of immediate-loaded short implants is comparable to conventional loading Methods. However, more marginal bone loss is expected. Overall, the immediate loading of short dental implants might be clinically successful. Conclusion: Based on the results, immediate loading protocols might be safely used for short implants. However, caution should be exercised in interpreting these results.Future welldesigned randomized clinical trials with more participants and study power are necessary to support the findings of this systematic review.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA