Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 63(21): 215017, 2018 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-30372423

RESUMO

Quantification of myocardial perfusion by contrast-enhanced cardiovascular magnetic resonance imaging (CMR) aims for an observer independent and reproducible risk assessment of cardiovascular disease. Currently, the data used for the pixel-wise analysis of cardiac perfusion are either filtered prior to a fitting procedure, which inherently reduces the spatial resolution of data; or all pixels are considered without any regularization or prior filtering, which yields an unstable fit in the presence of low signal-to-noise ratio. Here, we propose a new pixel-wise analysis based on spatial Tikhonov regularization which exploits the spatial smoothness of the data and ensures accurate quantification even for images with low signal-to-noise ratio. The regularization parameter is determined automatically by an L-curve criterion. We study the performance of our method on a numerical phantom and demonstrate that the method reduces significantly the root-mean square error in the perfusion estimate compared to a non-regularized fit. In patient data our method allows us to recover the myocardial perfusion and to distinguish between healthy and ischemic regions.


Assuntos
Circulação Coronária , Estatística como Assunto/métodos , Humanos , Análise de Regressão
2.
Anal Chem ; 89(4): 2242-2249, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28192939

RESUMO

This study presents an upgraded electrospray differential mobility analysis (ES-DMA) setup for the absolute quantification of bionanoparticle concentrations in biological samples, with a special focus on non-high-density-lipoprotein particle concentrations (non-HDL-P). Metrological characterization of the system's analytical performances for concentration measurements shows that the mean intermediate precision relative standard deviation is 14% for biological samples, 6% for silica nanoparticles, and less than 1% for diameter measurements. This study also demonstrates that the most accurate method for non-HDL-P quantification in native serum samples implies daily calculation of the electrospray transmission efficiency (E) of the system with the WHO SP3-08 reference material. The establishment of the uncertainty budget reveals that the main contribution to particle concentration measurement uncertainties is the electrospray transmission efficiency. This data additionally shows that E is not only low (approximately 15-20%) but also highly variable over time and strongly affected by sample composition. This work suggests that absolute enumeration of bionanoparticles is achievable with ES-DMA but provided that a special care is taken to quantifying E with a calibrator of nature and matrix highly similar to the samples ones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...