Appl Ergon ; 82: 102966, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31600711

RESUMO

Firefighting is a dangerous occupation and even training carries substantial risks. Self-contained breathing apparatus confidence courses (SCBACC) are a common type of training. PURPOSE: Compare the physiological strain of SCBACC to live-fire training (LFT) and circuit training (CT) among academy cadets. METHODS: Cadets wore physiologic status monitors to assess heart rate (HR) and estimated core temperature (ECT) during CT, LFT, and SCBACC of similar duration (33-38 min). RESULTS: Data from 52 cadet firefighters (28 ±â€¯4 yrs old) were analyzed. ECT (38.6 ±â€¯0.4 vs 39.3 ±â€¯0.7 vs. 39.3 ±â€¯0.6ᵒC), peak HR (182.6 ±â€¯9.1 vs. 192.7 ±â€¯9.5 vs 195.9 ±â€¯9.6 bpm), and age-predicted maximal HR (APMHR%; 94.6 ±â€¯4.6 vs 99.9 ±â€¯4.9 vs. 101.5 ±â€¯4.8%) were significantly (p < 0.05) lower for CT than SCBACC and LFT, respectively. CONCLUSIONS: SCBACC produced physiological strain greater than CT and similar to LFT. SCBACC resulted in sustained HR at 100% of age-predicted maximal values, a peak ECT of 39.3 °C, and should be considered as physiologically stressful as LFT.


Assuntos
Exercícios em Circuitos , Bombeiros/educação , Esforço Físico/fisiologia , Adulto , Temperatura Corporal/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS