Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Eur J Oncol Nurs ; 70: 102591, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38652933

RESUMO

PURPOSE: It is unclear whether the Geriatric-8 (G8) has the accuracy to preselect patients for complete geriatric assessment, and has the ability to predict adverse outcomes in patients with colorectal cancer (CRC). We therefore aimed to determine whether the G8, or other variables present in the medical record, are applicable in predicting 30-day adverse outcomes in older patients undergoing surgery for CRC. METHODS: We performed a retrospective cohort study involving patients ≥70 years who had surgery for CRC between 2018 and 2020 in a general hospital in the Netherlands. The primary outcome was adverse outcome(s), which is a composite of surgical and non-surgical complications, readmission and mortality, all within 30 days of surgery. The secondary endpoints were the individual components, such as delirium, infection and ileus. We explored potential prognostic factors using multivariable logistic regression analysis. Data were collected from the Dutch ColoRectal Audit (DRCA) and medical records. RESULTS: The study included 200 patients (mean age 78.9 years: 50% female), with 36.5% having adverse outcomes in the first 30 days of surgery. In neither univariate nor multivariable analysis were G8 scores associated with adverse outcomes. Factors with higher odds of adverse outcomes were male gender, and having cognitive decline or previous delirium. CONCLUSION: This study confirms that G8 scores have no prognostic value for adverse outcomes, complications and mortality within 30 days of surgery among older adults with CRC. Therefore, the G8 should not be the tool for short-term risk prediction of adverse outcomes in these patients.


Assuntos
Neoplasias Colorretais , Avaliação Geriátrica , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos de Coortes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/mortalidade , Países Baixos , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Estudos Retrospectivos , Medição de Risco
2.
BMC Neurol ; 22(1): 423, 2022 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-36371162

RESUMO

BACKGROUND: We designed a new multi-modal version of the MSmonitor, called the MSmonitor-Plus and Video calling Care (MPVC), a self-management and education program with e-health interventions that combines frequent use of specific questionnaires with video calling in treating multiple sclerosis (MS) patients. OBJECTIVE: To assess the effectiveness, cost-effectiveness and feasibility of MPVC compared to care as usual (CAU), with the goal of achieving equal or better quality of life for MS patients and their partners/informal caregivers. Our hypothesis is that by using MPVC, monitoring will become more efficient, that patients' self-efficacy, quality of life, and adherence to treatment will improve, and that they will be able to live their lives more autonomously. METHODS: A randomized, parallel-group, open label, non-inferiority trial will be conducted to compare MPVC with CAU in MS patients and their partners/informal caregivers. A total of 208 patients will be included with follow-up measurements for 2 years (at baseline and every 3 months). One hundred four patients will be randomized to MPVC and 104 patients to CAU. Partners/informal caregivers of both groups will be asked to participate. The study will consist of three parts: 1) a clinical effectiveness study, 2) an economic evaluation, and 3) a process evaluation. The primary outcome relates to equal or improved disease-specific physical and mental quality of life of the MS patients. Secondary outcomes relate to self-efficacy, efficiency, cost-effectiveness, autonomy, satisfaction with the care provided, and quality of life of partners/informal caregivers. DISCUSSION: The idea behind using MPVC is that MS patients will gain more insight into the individual course of the disease and get a better grip on their symptoms. This knowledge should increase their autonomy, give patients more control of their condition and enable them to better and proactively interact with health care professionals. As the consulting process becomes more efficient with the use of MPVC, MS-related problems could be detected earlier, enabling earlier multidisciplinary care, treatment or modification of the treatment. This could have a positive effect on the quality of life for both the MS patient and his/her partner/informal caregiver, reducing health and social costs. TRIAL REGISTRATION: NCT05242731 Clinical Trials.gov. Date of registration: 16 February 2022 retrospectively registered.


Assuntos
Esclerose Múltipla , Autogestão , Feminino , Humanos , Masculino , Cuidadores , Análise Custo-Benefício , Esclerose Múltipla/terapia , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Inquéritos e Questionários , Estudos de Equivalência como Asunto
3.
Front Cardiovasc Med ; 9: 851397, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35497982

RESUMO

Background: Periodontitis is a chronic multifactorial inflammatory disease of the supportive tissues of the teeth. In more recent years, remarkable epidemiological and pathophysiological associations between periodontitis and cardiovascular disease (CVD) have been presented. Whether or not treatment of periodontitis is valuable for primary or secondary prevention of cardiovascular disease, has not yet been fully established. In this practice-based pilot study we focused on primary prevention of cardiovascular disease, by investigating the effect of periodontal treatment on the earliest detectable stage of CVD; endothelial dysfunction. Methods: Otherwise healthy periodontitis and non-periodontitis participants 45-70 years of age were included in the study. One year after completing periodontal (non-surgical and surgical) treatment of the periodontitis patients and 1 year after inclusion of the controls, all baseline measurements were repeated. Full-mouth examinations were performed by a periodontist to determine their Periodontal Inflamed Surface Area (PISA) score and other dental parameters. To assess the cardiovascular conditions, endothelial function through the reactive hyperemia index (RHI) assessed by the EndoPAT™, and several physical and biochemical parameters were measured. Results: 21 patients with diagnosed, untreated periodontitis and 21 participants without periodontitis were included in this follow-up study. After periodontal therapy in the periodontitis patients, the PISA reduced significantly. The RHI did not show a significant improvement after treatment of the periodontitis patients (-0.1 ± 0.8, p = 0.524). Similarly, other secondary cardiovascular outcome measurements, hsCRP, total cholesterol, HDL cholesterol, triglycerides, HbA1c, and systolic blood pressure did not improve significantly after periodontal treatment. Controls did not show any significant changes in the RHI, in other CVD parameters and in the PISA after 1-year follow-up. Conclusion: In this practice-based pilot study, periodontal treatment did not improve the endothelial function in otherwise healthy adults with periodontitis. Future studies are needed to be of larger size and could focus on periodontitis patients with co-morbidities to investigate whether periodontal treatment has secondary preventive effect on endothelial function and other CVD parameters. Clinical Trial Registration: [www.ClinicalTrials.gov], identifier [ISRCTN55656827].

4.
J Clin Monit Comput ; 36(2): 355-361, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33496941

RESUMO

PURPOSE: Blood glucose (BG) concentrations of patients with diabetes mellitus (DM) are monitored during surgery to prevent hypo- and hyperglycemia. Access to point-of-care test (POCT) glucose meters at an operating room will usually provide monitoring at shorter intervals and may improve glycemic control. However, these meters are not validated for patients under general anesthesia. METHODS: This cross-sectional study included 75 arterial BG measurements from 75 patients (71 with DM, mostly insulin dependent) who underwent elective non-cardiac surgery under general anesthesia. Arterial blood samples were taken at least 60 minutes after induction. One drop of blood was used for Accu Chek Inform II (ACI II) POCT BG meter and the residual blood was sent to the clinical laboratory for a Hexokinase Plasma reference method. A Bland-Altman plot was used to visualize the differences between both methods, and correlation was assessed using the intra-class correlation coefficient (ICC). RESULTS: The results showed an estimated mean difference of 0.8 mmol/L between ACI II and the reference method, with limits of agreement equal to -0.6 and 2.2 mmol/L. In general, the reference method produced higher values than ACI II. ICC was 0.955 (95% CI 0.634-0.986), P < 0.001, and concordance correlation coefficient (CCC) was 0.955 (95% CI 0.933-0.970). CONCLUSION: Arterial BG measurements during surgery in patients with DM under general anesthesia using POCT BG meter are in general lower than laboratory measurements, but the ICC and CCC show a clinically acceptable correlation. We conclude that POCT measurements conducted on arterial specimens using the ACI II provide sufficiently accurate results for glucose measurement during surgery under general anesthesia.


Assuntos
Glicemia , Diabetes Mellitus , Anestesia Geral , Estudos Transversais , Hexoquinase , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos
5.
Gen Hosp Psychiatry ; 73: 9-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34507078

RESUMO

BACKGROUND: Methylphenidate (MPD) is increasingly prescribed to fertile women with Attention-Deficit Disorder (AD(H)D), with or without hyperactivity, despite advice for discontinuation during pregnancy. Few studies report on results concerning safety after methylphenidate exposure during pregnancy for the offspring. AIM: Safety for the offspring of exposure to MPD during pregnancy. METHODS: This is an observational retrospective cohort study in a population of pregnant women and their offspring, treated with MPD for ADHD in the Psychiatry-Gynaecology-Pediatrics outpatient clinic between 1 January 2005 and 1 June 2020 at Isala hospital. The primary endpoints were birth weight and Apgar score in offspring exposed to MPD during pregnancy, compared to offspring unexposed to MPD. Birth weight was analysed using linear mixed model analysis. Apgar score and (secondary endpoint) neonatal malformations, at 20 week ultrasound, were analysed using basic univariate statistical analysis. RESULTS: MPD continuation, compared to discontinuation, was associated with higher neonatal birth weight (p = 0.049), but lost statistical significance after incorporating covariates (p = 0.079). There were no significant differences in Apgar scores and congenital malformations between neonates exposed and unexposed to MPD. CONCLUSIONS: MPD does not seem to affect birth weight, Apgar score and the frequency of neonatal malformations at the 20 week ultrasound.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Estimulantes do Sistema Nervoso Central , Metilfenidato , Índice de Apgar , Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Transtorno do Deficit de Atenção com Hiperatividade/epidemiologia , Peso ao Nascer , Estimulantes do Sistema Nervoso Central/efeitos adversos , Criança , Feminino , Humanos , Recém-Nascido , Metilfenidato/efeitos adversos , Gravidez , Estudos Retrospectivos
6.
J Clin Transl Endocrinol ; 22: 100237, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33102135

RESUMO

AIMS: To identify factors predicting HbA1c reduction in patients with diabetes mellitus (DM) using FreeStyle Libre Flash Glucose Monitoring (FSL-FGM). METHODS: Data from a 12-month prospective nation-wide FSL registry were used and analysed with multivariable regression. For the present study we included patients with hypoglycaemia unawareness or unexpected hypoglycaemias (n = 566) and persons who did not reach acceptable glycaemic control (HbA1c > 70 mmol/mol (8.5%)) (n = 294). People with other indications for use, such as sensation loss of the fingers or individuals already using FSL-FGM or rtCGM, were excluded (37%). RESULTS: Eight hundred and sixty persons (55% male with a mean age of 46.7 (±16.4) years) were included. Baseline HbA1c was 65.1 (±14.5) mmol/mol (8.1 ± 1.3%), 75% of the patients had type 1 DM and 37% had microvascular complications. Data concerning HbA1c was present for 482 (56.0%) at 6 months and 423 (49.2%) persons at 12 months. A significant reduction in HbA1c (≥5 mmol/mol (0.5%)) was present in 187 (22%) persons. For these persons, median HbA1c reduction was -9.0 [-13.0, -4.0] mmol/mol (-0.82 [-1.19, -0.37]%) at 6 months and -9.0 [-15.0, -7.0] mmol/mol (-0.82 [-1.37, -0.64]%) at 12 months. In multivariable regression analysis with age, gender and SF-12 physical and mental component scores as covariates, only baseline HbA1c was significant: -0.319 (SE 0.025; p < 0.001; R2 = 0.240 for the model). In exploratory analysis among subgroups with different indications for FSL-FGM use (hypoglycaemia unawareness or persistently high HbA1c) and persons with a significant HbA1c decrease over the study period, baseline HbA1c remained the only significant predictor. CONCLUSIONS: Among the variables we analysed in the present study, only high HbA1c at baseline predicts significant HbA1c reduction during FSL-CGM use.

8.
Int J Endocrinol ; 2019: 4649303, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31781209

RESUMO

In patients with diabetes mellitus (DM), adequate glucose control is of major importance. When treatment schemes become more complicated, proper self-management through intermittent self-measurement of blood glucose (SMBG), among others, becomes crucial in achieving this goal. In the last decade, continuous glucose monitoring (CGM) has been on the rise, providing not only intermittent information but also information on continuous glucose trends. The FreeStyle Libre (FSL) Flash CGM system is a CGM system mainly used for patients with DM and is designed based on the same techniques as early CGMs. Compared with earlier CGMs, the FSL is factory calibrated, has no automated readings or direct alarms, and is cheaper to use. Although less accurate compared with the gold standard for SMBG, users report high satisfaction because it is easy to use and can help users monitor glucose trends. The Flash Monitor Register in the Netherlands (FLARE-NL) study aims to assess the effects of FSL Flash CGM use in daily practice. The study has a before-after design, with each participant being his or her own control. Users will be followed for at least 1 year. The endpoints include changes in HbA1c, frequency and severity of hypoglycemias, and quality of life. In addition, the effects of its use on work absenteeism rate, diabetes-related hospital admission rate, and daily functioning (including sports performance) will be studied. Furthermore, cost-benefit analysis based on the combination of registered information within the health insurance data will be investigated. Ultimately, the data gathered in this study will help increase the knowledge and skills of the use of the Flash CGM in daily practice and assess the financial impact on the use of the Flash CGM within the Dutch healthcare system.

9.
Insights Imaging ; 10(1): 102, 2019 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-31591646

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of hybrid iterative reconstruction and post processing on emphysema quantification in low-dose CT scans of COPD patients using pulmonary function tests (PFT) as a reference. METHODS: CT scans of 23 COPD patients diagnosed with GOLD I or higher were reconstructed with iDose4 level 1 to 7 in IntelliSpace Portal (ISP) 6 and 7. ISP7 was used with and without specific denoising filter for COPD. The extent of emphysema was measured as percentage of lung voxels with attenuation < - 950 Hounsfield units (%LAA-950). The correlation between %LAA-950 and PFT, age, BMI, pack years, and the Clinical COPD Questionnaire (CCQ) and Medical Research Council dyspnea scale (MRC) was determined. RESULTS: Denoising significantly reduced %LAA-950 as was demonstrated by lower %LAA-950 in ISP7 with denoising filter and a significant reduction in %LAA-950 with higher iDose4 levels. All PFT except forced vital capacity (FVC) were significantly inversely correlated with %LAA-950. There was a trend toward a stronger correlation at higher iDose4 levels. %LAA-950 was also significantly correlated with BMI, GOLD class, and CCQ scores. CONCLUSIONS: Our study showed that hybrid iterative reconstruction and use of post processing denoising can optimize the use of emphysema quantification in CT scans as a complimentary diagnostic tool to stage COPD in addition to PFT.

10.
Sci Rep ; 8(1): 12052, 2018 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-30104571

RESUMO

Biomimetic composites are usually made by combining hard and soft phases using, for example, multi-material additive manufacturing (AM). Like other fabrication methods, AM techniques are limited by the resolution of the device, hence, setting a minimum length scale. The effects of this length scale on the performance of hard-soft composites are not well understood. Here, we studied how this length scale affects the fracture toughness behavior of single-edge notched specimens made using random, semi-random, and ordered arrangements of the hard and soft phases with five different ratios of hard to soft phases. Increase in the length scale (40 to 960 µm) was found to cause a four-fold drop in the fracture toughness. The effects of the length scale were also modulated by the arrangement and volumetric ratio of both phases. A decreased size of the crack tip plastic zone, a crack path going through the soft phase, and highly strained areas far from the crack tip were the main mechanisms explaining the drop of the fracture toughness with the length scale.


Assuntos
Materiais Biomiméticos/análise , Materiais Biomiméticos/síntese química , Biomimética/métodos , Resinas Compostas/análise , Teste de Materiais/métodos , Estresse Mecânico , Dureza
11.
BMJ Open Diabetes Res Care ; 5(1): e000320, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28243449

RESUMO

OBJECTIVE: To evaluate the performance of the FreeStyle Libre Flash continuous glucose monitoring (FSL-CGM) system against established central laboratory methods. RESEARCH DESIGN AND METHODS: 20 subjects (8 type 1 diabetes mellitus, 12 type 2 diabetes mellitus) were analyzed. FSL-CGM sensor measurements (inserted in arm and abdomen) were compared with capillary blood glucose results analyzed with StatStrip as semigold standard. The glucose response after a standardized oral glucose load was measured by FSL-CGM and capillary samples analyzed by perchloric acid hexokinase (PCA-HK) method, StatStrip and FSL test strip (FSLC), and a commonly used CGM system (iPro2). RESULTS: FSL-CGM arm sensor readings showed 85.5% of paired readings falling within Clarke Error Grid (ISO 15197:2013) zone A when compared with StatStrip. For FSL-CGM abdomen and FSLC, these percentages were 64% and 98%, respectively. The overall correlation of FSL-CGM in the arm and the StatStrip indicates a performance with lower results with the FSL-CGM in the arm than expected based on the StatStrip in the lower glucose ranges, and higher results than expected in the higher ranges. Following a standardized glucose load, a slower rise in glucose level was observed for FSL-CGM arm as compared with PCA-HK, StatStrip, FSLC, and iPro2 during the first 45-60 min after glucose load ingestion. CONCLUSIONS: Certain matters need attention while using the FSL-CGM in daily life including the observed lower values in the lower ranges, and the underestimation of the effect of a meal on glucose response. These effects of such deviations can partly be overcome by optimizing the available user instructions. TRIAL REGISTRATION NUMBER: TC5348; results.

12.
Eur J Radiol ; 88: 61-70, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28189210

RESUMO

PURPOSE: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. METHODS: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. RESULTS: In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. CONCLUSIONS: Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys.


Assuntos
Artefatos , Prótese de Quadril , Metais , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Razão Sinal-Ruído , Titânio
13.
Skeletal Radiol ; 46(5): 623-632, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28204857

RESUMO

OBJECTIVE: To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. MATERIALS AND METHODS: Scans were acquired from high- to low-dose (CTDIvol: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose4 level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. RESULTS: The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose4 in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. CONCLUSIONS: Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose4 in the CT imaging of a THA phantom.


Assuntos
Artroplastia de Quadril , Artefatos , Processamento de Imagem Assistida por Computador/métodos , Metais , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Articulação do Quadril/diagnóstico por imagem , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes
14.
J Urol ; 189(2): 626-32, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23079372

RESUMO

PURPOSE: In this study we prospectively investigated the contribution of restored penile sensation to sexual health in patients with low spinal lesions. MATERIALS AND METHODS: In 30 patients (18 with spina bifida, 12 with spinal cord injury, age range 13 to 55 years) with no penile sensation but good groin sensation the new TOMAX (TO MAX-imize sensation, sexuality and quality of life) procedure was performed. This involves microsurgical connection of the sensory ilioinguinal nerve to the dorsal nerve of the penis unilaterally. Extensive preoperative and postoperative neurological and psychological evaluations were made. RESULTS: A total of 24 patients (80%) gained unilateral glans penis sensation. This was initially felt as groin sensation but transformed into real glans sensation in 11 patients (33%). These patients had better overall sexual function (p = 0.022) and increased satisfaction (p = 0.004). Although 13 patients (43%) maintained groin sensation, their satisfaction with sexuality was only slightly less than that of those with glans sensation. Improved sensations helped them manage urinary incontinence, thereby improving personal hygiene and independence. Most patients felt more complete and less handicapped with their penis now part of their body image. They also reported having more open and meaningful sexual relationships with their partners. CONCLUSIONS: Tactile and erogenous sensitivity was restored in the glans penis in patients with a low spinal lesion. This new sensation enhanced the quality of sexual functioning and satisfaction. The TOMAX procedure should become standard treatment for such patients.


Assuntos
Hipestesia/etiologia , Hipestesia/cirurgia , Satisfação do Paciente , Pênis/inervação , Pênis/cirurgia , Qualidade de Vida , Saúde Reprodutiva , Sensação , Traumatismos da Medula Espinal/complicações , Disrafismo Espinal/complicações , Adolescente , Adulto , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade , Pênis/fisiologia , Estudos Prospectivos , Procedimentos Cirúrgicos Urológicos Masculinos/métodos , Adulto Jovem
15.
Obes Rev ; 10(4): 412-9, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19413701

RESUMO

Recognition of the link between non-alcoholic fatty liver disease (NAFLD) and cardiovascular disease (CVD) has boosted research in this area. The main objective of this paper is to review the literature on NAFLD in the context of CVD, focussing on underlying mechanisms and treatment. Besides excessive fatty acid influx, etiologic factors may include components of the metabolic syndrome, cytokines and mitochondrial dysfunction. NAFLD is associated with both hepatic and systemic insulin resistance. In the case of NAFLD, the liver overproduces several atherogenic factors, notably inflammatory cytokines, glucose, lipoproteins and coagulation factors, and factors increasing blood pressure. Intervention studies on diet and laparoscopic surgery revealed improvements of hepatic fat content and CVD risk profile. Pharmacological approaches with potential benefit have been developed as well, but effects are often confounded by weight change. NAFLD is associated with an increased CVD risk profile (and hepatic risk). In order to improve CVD risk profile, prevention and treatment of NAFLD seem advisable. However, well-designed intervention studies, randomized clinical trials and long-term follow-up studies are scarce.


Assuntos
Doenças Cardiovasculares/epidemiologia , Fígado Gorduroso/complicações , Obesidade/complicações , Biomarcadores/sangue , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/prevenção & controle , Fígado Gorduroso/epidemiologia , Fígado Gorduroso/prevenção & controle , Humanos , Resistência à Insulina , Obesidade/epidemiologia , Obesidade/prevenção & controle , Prevalência , Fatores de Risco
16.
Clin Nephrol ; 66(4): 306-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17064000

RESUMO

Cystinosis is a rare metabolic disorder characterized by lysosomal cystine accumulation leading to multi-organ damage, with kidneys being clinically first affected. Longer survival of cystinosis patients due to successful renal replacement therapy, revealed previously unknown extra-renal symptoms of cystinosis, generally appearing after the first decade. Respiratory insufficiency caused by overall respiratory muscle myopathy is a severely invalidating and sometimes a life-threatening complication of cystinosis. We report a successful treatment of hypoventilation, due to diaphragm myopathy in a cystinosis patient, by nocturnal non-invasive positive pressure ventilation (NIPPV). After initiation of NIPPV the clinical condition of the patient improved and blood-gasses normalized, indicating that this treatment modality should be considered in cystinosis patients with severe respiratory insufficiency.


Assuntos
Cistinose/complicações , Respiração com Pressão Positiva/métodos , Transtornos Respiratórios/complicações , Transtornos Respiratórios/terapia , Adulto , Gasometria , Humanos , Masculino , Fenômenos Fisiológicos Respiratórios , Decúbito Dorsal
17.
Mol Biol Cell ; 15(6): 2853-62, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15075369

RESUMO

Epithelial cells in vivo form tight cell-cell associations that spatially separate distinct apical and basolateral domains. These domains provide discrete cellular processes essential for proper tissue and organ development. Using confocal imaging and selective plasma membrane domain activation, the type I and type II transforming growth factor-beta (TGFbeta) receptors were found to be localized specifically at the basolateral surfaces of polarized Madin-Darby canine kidney (MDCK) cells. Receptors concentrated predominantly at the lateral sites of cell-cell contact, adjacent to the gap junctional complex. Cytoplasmic domain truncations for each receptor resulted in the loss of specific lateral domain targeting and dispersion to both the apical and basal domains. Whereas receptors concentrate basolaterally in regions of direct cell-cell contact in nonpolarized MDCK cell monolayers, receptor staining was absent from areas of noncell contact. In contrast to the defined basolateral polarity observed for the TGFbeta receptor complex, TGFbeta ligand secretion was found to be from the apical surfaces. Confocal imaging of MDCK cells with an antibody to TGFbeta1 confirmed a predominant apical localization, with a stark absence at the basal membrane. These findings indicate that cell adhesion regulates the localization of TGFbeta receptors in polarized epithelial cultures and that the response to TGFbeta is dependent upon the spatial distribution and secretion of TGFbeta receptors and ligand, respectively.


Assuntos
Polaridade Celular , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Receptores de Fatores de Crescimento Transformadores beta/metabolismo , Fator de Crescimento Transformador beta/metabolismo , Junções Aderentes/metabolismo , Animais , Adesão Celular , Linhagem Celular , Membrana Celular/metabolismo , Polaridade Celular/efeitos dos fármacos , Cães , Humanos , Ligantes , Transporte Proteico , Receptores de Fatores de Crescimento Transformadores beta/química , Receptores de Fatores de Crescimento Transformadores beta/genética , Deleção de Sequência/genética , Transfecção , Fator de Crescimento Transformador beta/farmacologia
18.
Vet Microbiol ; 96(2): 145-55, 2003 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-14519332

RESUMO

Bovine viral diarrhea virus (BVDV) is a significant pathogen that can be shed in the semen of infected bulls. Thus, screening for BVDV in semen of bulls is recommended prior to their entry into an artificial insemination center. No previous research has compared the analytical sensitivity of reverse transcription-nested polymerase chain reaction (RT-nPCR) and virus isolation assays for detection of BVDV in semen from an infected bull. Therefore, the goals of this research were to compare the analytical sensitivity of RT-nPCR and virus isolation assays for BVDV in semen and to apply these assays to determine the prevalence in the Southeastern United States of bulls that lack viremia yet shed BVDV in semen. Semen collected from a bull that was persistently infected with BVDV was serially diluted (1/10) in semen from uninfected bulls and frozen in liquid nitrogen as raw, partially extended or fully extended semen. Subsequently, samples of semen were assayed by virus isolation and RT-nPCR. Viral detection was more sensitive in extended semen samples than in raw semen samples and more sensitive by RT-nPCR than virus isolation. After this evaluation of analytical sensitivity, serum and semen were collected from 558 post-pubertal bulls in our region. These samples were tested for BVDV by virus isolation. Partially extended semen was also assayed for BVDV by RT-nPCR. All samples were negative by all assays for BVDV. The application of analytically sensitive assays reveals a very low prevalence (

Assuntos
Doença das Mucosas por Vírus da Diarreia Viral Bovina/diagnóstico , Vírus da Diarreia Viral Bovina/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Sêmen/virologia , Animais , Doença das Mucosas por Vírus da Diarreia Viral Bovina/epidemiologia , Bovinos , Vírus da Diarreia Viral Bovina/genética , Masculino , Prevalência , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Sensibilidade e Especificidade , Sudeste dos Estados Unidos/epidemiologia
19.
J Immunol ; 167(8): 4161-71, 2001 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-11591736

RESUMO

This study tested the hypothesis that certain secretory phospholipase A(2) (sPLA(2)) isotypes act in a cytokine-like fashion through cell surface receptors to influence mast cell survival. Initial experiments revealed that sPLA(2) activity and sPLA(2) receptor expression are increased, and mast cells lost their capacity to maintain membrane asymmetry upon cytokine depletion. Groups IB and III, but not group IIA PLA(2), prevented the loss of membrane asymmetry. Similarly, group IB prevented nucleosomal DNA fragmentation in mast cells. Providing putative products of sPLA(2) hydrolysis to cytokine-depleted mast cells did not influence survival. Furthermore, catalytic inactivation of sPLA(2) did not alter its capacity to prevent apoptosis. Inhibition of protein synthesis using cycloheximide or actinomycin reversed the antiapoptotic effect of sPLA(2). Additionally, both wild-type and catalytically inactive group IB PLA(2) induced IL-3 synthesis in mast cells. However, adding IL-3-neutralizing Ab did not change Annexin V(FITC) binding and only partially inhibited thymidine incorporation in sPLA(2)-supplemented mast cells. In contrast, IL-3-neutralizing Ab inhibited both Annexin V(FITC) binding and thymidine incorporation in mast cells maintained with IL-3. sPLA(2) enhanced phosphoinositide 3'-kinase activity, and a specific inhibitor of phosphoinositide 3'-kinase reversed the antiapoptotic effects of sPLA(2). Likewise, sPLA(2) increased the degradation of I-kappaBalpha, and specific inhibitors of nuclear factor kappa activation (NF-kappaB) reversed the antiapoptotic effects of sPLA(2). Together, these experiments reveal that certain isotypes of sPLA(2) enhance the survival of mast cells in a cytokine-like fashion by activating antiapoptotic signaling pathways independent of IL-3 and probably via sPLA(2) receptors rather than sPLA(2) catalytic products.


Assuntos
Células da Medula Óssea/imunologia , Mastócitos/imunologia , Fosfolipases A/metabolismo , Receptores de Superfície Celular/metabolismo , Animais , Anexina A5/metabolismo , Apoptose , Ácido Araquidônico/farmacologia , Células da Medula Óssea/citologia , Sobrevivência Celular , Interleucina-3 , Isoenzimas/metabolismo , Lisofosfolipídeos/farmacologia , Mastócitos/citologia , Camundongos , NF-kappa B/antagonistas & inibidores , Inibidores de Fosfoinositídeo-3 Quinase , Ligação Proteica , Biossíntese de Proteínas , Receptores da Fosfolipase A2 , Transdução de Sinais , Transcrição Gênica
20.
Mol Biol Cell ; 12(9): 2881-93, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11553725

RESUMO

Transforming growth factor beta (TGF-beta) coordinates a number of biological events important in normal and pathophysiological growth. In this study, deletion and substitution mutations were used to identify receptor motifs modulating TGF-beta receptor activity. Initial experiments indicated that a COOH-terminal sequence between amino acids 482-491 in the kinase domain of the type I receptor was required for ligand-induced receptor signaling and down-regulation. These 10 amino acids are highly conserved in mammalian, Xenopus, and Drosophila type I receptors. Although mutation or deletion of the region (referred to as the NANDOR BOX, for nonactivating non-down-regulating) abolishes TGF-beta-dependent mitogenesis, transcriptional activity, type I receptor phosphorylation, and down-regulation in mesenchymal cultures, adjacent mutations also within the kinase domain are without effect. Moreover, a kinase-defective type I receptor can functionally complement a mutant BOX expressing type I receptor, documenting that when the BOX mutant is activated, it has kinase activity. These results indicate that the sequence between 482 and 491 in the type I receptor provides a critical function regulating activation of the TGF-beta receptor complex.


Assuntos
Endocitose , Receptores de Fatores de Crescimento Transformadores beta/química , Receptores de Fatores de Crescimento Transformadores beta/metabolismo , Transdução de Sinais , Motivos de Aminoácidos , Sequência de Aminoácidos , Linhagem Celular , Proteínas de Ligação a DNA/metabolismo , Regulação para Baixo , Fibroblastos , Fator Estimulador de Colônias de Granulócitos e Macrófagos/metabolismo , Humanos , Dados de Sequência Molecular , Mutagênese Sítio-Dirigida , Fosforilação , Inibidor 1 de Ativador de Plasminogênio/metabolismo , Estrutura Terciária de Proteína , Receptores de Fatores de Crescimento Transformadores beta/genética , Proteínas Recombinantes de Fusão/química , Proteínas Recombinantes de Fusão/genética , Proteínas Recombinantes de Fusão/metabolismo , Deleção de Sequência , Proteína Smad2 , Fatores de Tempo , Transativadores/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...