J Med Imaging (Bellingham) ; 5(2): 021216, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29487888

RESUMO

A projector-based augmented reality intracorporeal system (PARIS) is presented that includes a miniature tracked projector, tracked marker, and laparoscopic ultrasound (LUS) transducer. PARIS was developed to improve the efficacy and safety of laparoscopic partial nephrectomy (LPN). In particular, it has been demonstrated to effectively assist in the identification of tumor boundaries during surgery and to improve the surgeon's understanding of the underlying anatomy. PARIS achieves this by displaying the orthographic projection of the cancerous tumor on the kidney's surface. The performance of PARIS was evaluated in a user study with two surgeons who performed 32 simulated robot-assisted partial nephrectomies. They performed 16 simulated partial nephrectomies with PARIS for guidance and 16 simulated partial nephrectomies with only an LUS transducer for guidance. With PARIS, there was a significant reduction [30% ([Formula: see text])] in the amount of healthy tissue excised and a trend toward a more accurate dissection around the tumor and more negative margins. The combined point tracking and reprojection root-mean-square error of PARIS was 0.8 mm. PARIS' proven ability to improve key metrics of LPN surgery and qualitative feedback from surgeons about PARIS supports the hypothesis that it is an effective surgical navigation tool.

2.
Healthc Technol Lett ; 4(5): 204-209, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29184666

RESUMO

In laparoscopic surgery, the surgeon must operate with a limited field of view and reduced depth perception. This makes spatial understanding of critical structures difficult, such as an endophytic tumour in a partial nephrectomy. Such tumours yield a high complication rate of 47%, and excising them increases the risk of cutting into the kidney's collecting system. To overcome these challenges, an augmented reality guidance system is proposed. Using intra-operative ultrasound, a single navigation aid, and surgical instrument tracking, four augmentations of guidance information are provided during tumour excision. Qualitative and quantitative system benefits are measured in simulated robot-assisted partial nephrectomies. Robot-to-camera calibration achieved a total registration error of 1.0 ± 0.4 mm while the total system error is 2.5 ± 0.5 mm. The system significantly reduced healthy tissue excised from an average (±standard deviation) of 30.6 ± 5.5 to 17.5 ± 2.4 cm3 (p < 0.05) and reduced the depth from the tumor underside to cut from an average (±standard deviation) of 10.2 ± 4.1 to 3.3 ± 2.3 mm (p < 0.05). Further evaluation is required in vivo, but the system has promising potential to reduce the amount of healthy parenchymal tissue excised.

3.
Med Image Anal ; 25(1): 95-102, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26024818

RESUMO

The Pico Lantern is a miniature projector developed for structured light surface reconstruction, augmented reality and guidance in laparoscopic surgery. During surgery it will be dropped into the patient and picked up by a laparoscopic tool. While inside the patient it projects a known coded pattern and images onto the surface of the tissue. The Pico Lantern is visually tracked in the laparoscope's field of view for the purpose of stereo triangulation between it and the laparoscope. In this paper, the first application is surface reconstruction. Using a stereo laparoscope and an untracked Pico Lantern, the absolute error for surface reconstruction for a plane, cylinder and ex vivo kidney, is 2.0 mm, 3.0 mm and 5.6 mm, respectively. Using a mono laparoscope and a tracked Pico Lantern for the same plane, cylinder and kidney the absolute error is 1.4 mm, 1.5 mm and 1.5 mm, respectively. These results confirm the benefit of the wider baseline produced by tracking the Pico Lantern. Virtual viewpoint images are generated from the kidney surface data and an in vivo proof-of-concept porcine trial is reported. Surface reconstruction of the neck of a volunteer shows that the pulsatile motion of the tissue overlying a major blood vessel can be detected and displayed in vivo. Future work will integrate the Pico Lantern into standard and robot-assisted laparoscopic surgery.


Assuntos
Aumento da Imagem/instrumentação , Rim/irrigação sanguínea , Laparoscópios , Laparoscopia/instrumentação , Lasers , Iluminação/instrumentação , Cirurgia Assistida por Computador/instrumentação , Animais , Desenho de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos , Interface Usuário-Computador
4.
Artigo em Inglês | MEDLINE | ID: mdl-25333147

RESUMO

The Pico Lantern is proposed as a new tool for guidance in laparoscopic surgery. Its miniaturized design allows it to be picked up by a laparoscopic tool during surgery and tracked directly by the endoscope. By using laser projection, different patterns and annotations can be projected onto the tissue surface. The first explored application is surface reconstruction. The absolute error for surface reconstruction using stereo endoscopy and untracked Pico Lantern for a plane, cylinder and ex vivo kidney is 2.0 mm, 3.0 mm and 5.6 mm respectively. The absolute error using a mono endoscope and a tracked Pico Lantern for the same plane, cylinder and kidney is 0.8mm, 0.3mm and 1.5mm respectively. The results show the benefit of the wider baseline produced by tracking the Pico Lantern. Pulsatile motion of a human carotid artery is also detected in vivo. Future work will be done on the integration into standard and robot-assisted laparoscopic surgery.


Assuntos
Laparoscópios , Iluminação/instrumentação , Robótica/instrumentação , Cirurgia Assistida por Computador/instrumentação , Interface Usuário-Computador , Desenho de Equipamento , Análise de Falha de Equipamento