Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 90(1): 139-146, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28029207

RESUMO

OBJECTIVE: We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and SAPIEN XT (SXT) for the treatment of severe aortic stenosis (AS). BACKGROUND: Very few data on TAVR devices are available beyond MCV and SAPIEN and there is no previous study comparing ACT with MCV and SXT. METHODS: We prospectively evaluated consecutive patients who underwent transfemoral TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: A total of 162 patients (ACT n = 49, MCV n = 56, SXT n = 57), were included. MCV group had higher valve embolization/migration rates (ACT none; MCV 9%; SXT 2%; P = 0.034) causing lower device success rates (ACT 98%; MCV 86%; SXT 95%; P = 0.043). At 30 days, there was no significant difference in all-cause mortality (P = 0.22), cardiovascular mortality (P = 0.20), periprocedural myocardial infarction (P = 0.40), stroke (P = 0.64), major vascular complications (P = 0.48), life-threatening bleeding (P = 0.29), acute kidney injury stage 2/3 (P = 0.69), or VARC-2 composite early safety endpoints (P = 0.21). MCV group had higher rates of new permanent pacemaker implantation (ACT 6%; MCV 25%; SXT 11%; P = 0.013). Follow-up echocardiography showed no significant difference in aortic valve mean pressure gradient (P = 0.73) or moderate/severe aortic regurgitation (P = 0.19) between groups. CONCLUSIONS: In a "real world" registry, ACT compared favorably against the well-studied SXT and MCV devices in both safety and efficacy. MCV implantation was associated with lower device success rates and higher rates of new permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Equipe de Assistência ao Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 89(3): 452-459, 2017 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-27514499

RESUMO

OBJECTIVES: The objectives of the present study were to analyze the variation of renal function after transcatheter aortic valve replacement (TAVR) focused on acute kidney injury (AKI) and its impact on short- and mid-term mortality. BACKGROUND: Changes on renal function after TAVR and their impact on clinical outcomes are incompletely understood until now. METHODS: At two tertiary centers 221 consecutive patients were submitted to TAVR. Kidney injury was defined according to VARC-2 criteria. Patients were classified according to the presence (group 1) or absence (group 2) of AKI. Creatinine values were collected daily until seventh day after procedure, 1 month, 6 months, and then 1 year after TAVR. RESULTS: At baseline, groups were similar, except for EuroSCORE II (8.66% vs. 7.34%, P = 0.02) and glomerular filtration rate (GFR) (39.59 vs. 48.49 mL/min.1.73 m2 , P = 0.002). Overall 30 day-mortality and 1-year mortality were 6.3% and 14.0%, respectively. Both 30-day mortality (23.1% vs. 1.2%, P < 0.001) and 1-year mortality (44.2% vs. 4.7%, P < 0.001) were higher in group 1. After multivariable-adjusted models, the only independent predictor for AKI after TAVR was baseline GFR (HR: 1.37, 95% CI: 1.08-1.77, P = 0.01). The independent risk factors for 1-year mortality were AKI (HR: 15.66, 95% CI: 6.07-44.63, P < 0.001), COPD (HR: 3.14, 95% CI: 1.05-9.40, P = 0.04) and aortic regurgitation grade postprocedure ≥ 2 (P = 0.05) also after multivariate analysis. CONCLUSIONS: In this TAVR cohort, baseline GFR was the only independent predictor of AKI, which negatively impacted on 30-day and 1-year mortality. © 2016 Wiley Periodicals, Inc.


Assuntos
Injúria Renal Aguda/etiologia , Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Rim/fisiopatologia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Brasil , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Distribuição de Qui-Quadrado , Creatinina/sangue , Ecocardiografia , Feminino , Taxa de Filtração Glomerular , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 88(6): 953-960, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27143093

RESUMO

BACKGROUND: Alcohol septal ablation (ASA) is an alternative treatment for symptomatic hypertrophic obstructive cardiomyopathy (HOCM) patients refractory to pharmacological therapy. We sought to evaluate the immediate and long-term incidence of death and changes in life quality in a consecutive cohort submitted to ASA. METHODS AND RESULTS: Between October 1998 and December 2013, a total of 56 patients (mean age 53.2 ± 15.5) with symptomatic refractory HOCM were treated with ASA and followed during 15 years (mean 8 ± 4 years). There were 7 (12.5%) deaths, 2 (3.6%) being of cardiac cause. The Kaplan-Meier survival probability estimate was 96.4% at 1 year, 87.7 at 5 years and 81.0% at 12 years post-ASA. Significant improvement was observed in life quality assessed by DASI index and NYHA functional class as well as in the left ventricle outflow tract (LVOT) gradient reduction (from 92.8 ± 3.3 mm Hg to 9.37 ± 6.7 mm Hg, P < 0.001) and septum thickness (from 23.9 ± 0.6 mm to 12.9 ± 1.0 mm, P < 0.001). Only one patient (1.7%) required permanent pacemaker immediately after ASA. During follow-up, one patient had a repeated ASA, three patients underwent myectomy and other four required ICD/pacemaker. In the multivariate model only post-ASA LVOT residual gradient and left ventricle mass were associated with worse prognosis. CONCLUSIONS: In this long-term clinical follow-up without losses, ASA was effective in improving quality of life and NYHA functional class, with relatively low mortality and very low need for immediate permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Assuntos
Técnicas de Ablação/métodos , Cateterismo Cardíaco/métodos , Cardiomiopatia Hipertrófica/cirurgia , Etanol/administração & dosagem , Septos Cardíacos , Brasil/epidemiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/mortalidade , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...