Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 16(21): 4142-4151, 2016 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-27713988

RESUMO

Since the introduction of micro total analytical systems (µTASs), significant advances have been made toward development of lab-on-a-chip platforms capable of performing complex biological assays that can revolutionize public health, among other applications. However, use of these platforms in low-resource environments (e.g. developing countries) has yet to be realized as the majority of technologies used to control microfluidic flow rely on off-device hardware with non-negligible size, cost, power requirements and skill/training to operate. In this paper we describe a magnetic-adhesive based valve that is simple to construct and operate, and can be used to control fluid flow and store reagents within a microfluidic device. The design consists of a port connecting two chambers on different planes in the device that is closed by a neodymium disk magnet seated on a thin ring of adhesive. Bringing an external magnet into contact with the outer surface of the device unseats and displaces the valve magnet from the adhesive ring, exposing the port. Using this configuration, we demonstrate on-device reagent storage and on-demand transport and reaction of contents between chambers. This design requires no power or external instrumentation to operate, is extremely low cost ($0.20 materials cost per valve), can be used by individuals with no technical training, and requires only a hand-held magnet to actuate. Additionally, valve actuation does not compromise the integrity of the completely sealed microfluidic device, increasing safety for the operator when toxic or harmful substances are contained within. This valve concept has the potential to simplify design of µTASs, facilitating development of lab-on-a-chip systems that may be practical for use in point-of-care and low-resource settings.


Assuntos
Adesivos , Recursos em Saúde/provisão & distribuição , Dispositivos Lab-On-A-Chip , Imãs , Sistemas Automatizados de Assistência Junto ao Leito
2.
Biomed Opt Express ; 7(6): 2219-36, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27375939

RESUMO

We have developed a method for performing light-sheet microscopy with a single high numerical aperture lens by integrating reflective side walls into a microfluidic chip. These 45° side walls generate light-sheet illumination by reflecting a vertical light-sheet into the focal plane of the objective. Light-sheet illumination of cells loaded in the channels increases image quality in diffraction limited imaging via reduction of out-of-focus background light. Single molecule super-resolution is also improved by the decreased background resulting in better localization precision and decreased photo-bleaching, leading to more accepted localizations overall and higher quality images. Moreover, 2D and 3D single molecule super-resolution data can be acquired faster by taking advantage of the increased illumination intensities as compared to wide field, in the focused light-sheet.

3.
Electrophoresis ; 34(14): 2112-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24024241

RESUMO

A 3D finite element model was developed to optimize the kinetics and mass transfer characteristics of low concentration, 18 bp ssDNA targets in bulk media solution, to 18 bp complimentary oligonucleotide probes immobilized on electrochemical detection electrodes positioned along the length of a microfluidic channel. Conditions considered in the model were fluid flow rate, diffusion time, DNA melting temperature, number of matching base pairs, and temperature of the fluid in the channel. System optimization was based on maximizing the uniformity and surface concentration of the specifically bound hybridized DNA, minimizing waste volume generation and the hybridization time. With the coupled simulation method used, the total experiment time was reduced from 150 to 60 min and the simulated results were consistent with experimental results found in the literature. A stopped flow procedure was investigated as a means to improve hybridization. This procedure can not only improve uniformity and capture efficiency, and reduce waste, but can also decrease overall signal intensity relative to continuous flow operation. Finally, the use of temperature in reducing mismatched hybridization and improving duplex stability was also successfully modeled and simulated.


Assuntos
Simulação por Computador , DNA/análise , Técnicas Analíticas Microfluídicas/métodos , Modelos Químicos , Cinética , Movimento (Física) , Hibridização de Ácido Nucleico/métodos , Temperatura
4.
J Clin Microbiol ; 51(6): 1685-91, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23515541

RESUMO

Disasters can create situations in which blood donations can save lives. However, in emergency situations and when resources are depleted, on-site blood donations require the rapid and accurate detection of blood-borne pathogens, including human immunodeficiency virus types 1 and 2 (HIV-1 and HIV-2). Techniques such as PCR and antibody capture by an enzyme-linked immunosorbent assay (ELISA) for HIV-1 and HIV-2 are precise but time-consuming and require sophisticated equipment that is not compatible with emergency point-of-care requirements. We describe here a prototype biosensor based on piezoelectric materials functionalized with specific antibodies against HIV-1 and HIV-2. We show the rapid and accurate detection of HIV-1 and HIV-2 in both simple and complex solutions, including human serum, and in the presence of a cross-confounding virus. We report detection limits of 12 50% tissue culture infective doses (TCID50s) for HIV-1 and 87 TCID50s for HIV-2. The accuracy, precision of measurements, and operation of the prototype biosensor compared favorably to those for nucleic acid amplification. We conclude that the biosensor has significant promise as a successful point-of-care diagnostic device for use in emergency field applications requiring rapid and reliable testing for blood-borne pathogens.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas de Laboratório Clínico/métodos , Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Virologia/métodos , Técnicas Biossensoriais/instrumentação , Técnicas de Laboratório Clínico/instrumentação , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade , Virologia/instrumentação
5.
Langmuir ; 28(50): 17396-403, 2012 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-23163515

RESUMO

Electrostatic interaction plays a leading role in nanoparticle interactions with membrane architectures and can lead to effects such as nanoparticle binding and membrane disruption. In this work, the effects of nanoparticles (NPs) interacting with mixed lipid systems were investigated, indicating an ability to tune both NP binding to membranes and membrane disruption. Lipid membrane assemblies (LBAs) were created using a combination of charged, neutral, and gel-phase lipids. Depending on the lipid composition, nanostructured networks could be observed using in situ atomic force microscopy representing an asymmetrical distribution of lipids that rendered varying effects on NP interaction and membrane disruption that were domain-specific. LBA charge could be localized to fluidic domains that were selectively disrupted when interacting with negatively charged Au nanoparticles or quantum dots. Disruption was observed to be related to the charge density of the membrane, with a maximum amount of disruption occurring at ∼40% positively charged lipid membrane concentration. Conversely, particle deposition was determined to begin at charged lipid concentrations greater than 40% and increased with charge density. The results demonstrate that the modulation of NP and membrane charge distribution can play a pivitol role in determining NP-induced membrane disruption and NP surface assembly.


Assuntos
Ouro/química , Bicamadas Lipídicas/química , Nanopartículas Metálicas/química , Pontos Quânticos , Nanopartículas Metálicas/ultraestrutura , Microscopia de Força Atômica , Tamanho da Partícula , Eletricidade Estática
6.
J Vis Exp ; (64): e4067, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22688693

RESUMO

The development of a minimally invasive multiplexed monitoring system for rapid analysis of biologically-relevant molecules could offer individuals suffering from chronic medical conditions facile assessment of their immediate physiological state. Furthermore, it could serve as a research tool for analysis of complex, multifactorial medical conditions. In order for such a multianalyte sensor to be realized, it must be minimally invasive, sampling of interstitial fluid must occur without pain or harm to the user, and analysis must be rapid as well as selective. Initially developed for pain-free drug delivery, microneedles have been used to deliver vaccines and pharmacologic agents (e.g., insulin) through the skin. Since these devices access the interstitial space, microneedles that are integrated with microelectrodes can be used as transdermal electrochemical sensors. Selective detection of glucose, glutamate, lactate, hydrogen peroxide, and ascorbic acid has been demonstrated using integrated microneedle-electrode devices with carbon fibers, modified carbon pastes, and platinum-coated polymer microneedles serving as transducing elements. This microneedle sensor technology has enabled a novel and sophisticated analytical approach for in situ and simultaneous detection of multiple analytes. Multiplexing offers the possibility of monitoring complex microenvironments, which are otherwise difficult to characterize in a rapid and minimally invasive manner. For example, this technology could be utilized for simultaneous monitoring of extracellular levels of, glucose, lactate and pH, which are important metabolic indicators of disease states (e.g., cancer proliferation) and exercise-induced acidosis.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Microinjeções/instrumentação , Agulhas , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos
7.
Small ; 8(17): 2743-51, 2012 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-22684922

RESUMO

This is the first report of a living cell-based environmental sensing device capable of generating orthogonal fluorescent, electrochemical, and colorimetric signals in response to a single target analyte in complex media. Orthogonality is enabled by use of cellular communities that are engineered to provide distinct signals in response to the model analyte. Coupling these three signal transduction methods provides additional and/or complementary data regarding the sample which may reduce the impact of interferants and increase confidence in the sensor's output. Long-term stability of the cells was addressed via 3D entrapment within a nanostructured matrix derived from glycerated silicate, which allows the device to be sealed and stored under dry, ambient conditions for months with significant retention in cellular activity and viability (40% viability after 60 days). Furthermore, the first co-entrapment of eukaryotic and bacterial cells in a silica matrix is reported, demonstrating multianalyte biodetection by mixing disparate cell lines at intimate proximities which remain viable and responsive. These advances in cell-based biosensing open intriguing opportunities for integrating living cells with nanomaterials and macroscale systems.

8.
Talanta ; 88: 739-42, 2012 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-22265568

RESUMO

The development of a microneedle-based biosensor array for multiplexed in situ detection of exercise-induced metabolic acidosis, tumor microenvironment, and other variations in tissue chemistry is described. Simultaneous and selective amperometric detection of pH, glucose, and lactate over a range of physiologically relevant concentrations in complex media is demonstrated. Furthermore, materials modified with a cell-resistant (Lipidure(®)) coating were shown to inhibit macrophage adhesion; no signs of coating delamination were noted over a 48-h period.


Assuntos
Acidose/metabolismo , Técnicas Biossensoriais/métodos , Glucose/metabolismo , Ácido Láctico/análise , Acidose/diagnóstico , Técnicas Biossensoriais/instrumentação , Carbono , Adesão Celular , Materiais Revestidos Biocompatíveis , Técnicas Eletroquímicas , Exercício Físico , Glucose Oxidase/metabolismo , Humanos , Concentração de Íons de Hidrogênio , Ácido Láctico/biossíntese , Macrófagos/fisiologia , Microeletrodos , Agulhas
9.
Biomicrofluidics ; 5(1): 13415, 2011 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-21522504

RESUMO

In this study, carbon fiber electrodes were incorporated within a hollow microneedle array, which was fabricated using a digital micromirror device-based stereolithography instrument. Cell proliferation on the acrylate-based polymer used in microneedle fabrication was examined with human dermal fibroblasts and neonatal human epidermal keratinocytes. Studies involving full-thickness cadaveric porcine skin and trypan blue dye demonstrated that the hollow microneedles remained intact after puncturing the outermost layer of cadaveric porcine skin. The carbon fibers underwent chemical modification in order to enable detection of hydrogen peroxide and ascorbic acid; electrochemical measurements were demonstrated using integrated electrode-hollow microneedle devices.

10.
Biosens Bioelectron ; 26(8): 3641-6, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21411305

RESUMO

Nonenzymatic glucose oxidation is demonstrated on highly faceted palladium nanowflower-modified porous carbon electrodes fabricated by interference lithography. Varying electrodeposition parameters were used to control the final shape and morphology of the deposited nanoparticles on the 3D porous carbon which showed a 12 times increase in the electrochemically active surface area over analogous planar electrodes. Extremely fast amperometric glucose responses (achieving 95% of the steady state limiting current in less than 5s) with a linear range from 1 to 10mM and a detection limit of 10 µM were demonstrated. The unusual surface properties of the pyrolyzed photoresist films produced strongly adhered palladium crystal structures that were stable for hundreds of cycles towards glucose oxidation without noticeable current decay.


Assuntos
Técnicas Eletroquímicas/métodos , Eletrodos , Glucose/análise , Nanoporos , Ácido Ascórbico/química , Catálise , Oxirredução , Paládio/química
11.
Biomicrofluidics ; 5(4): 44115-4411514, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22276087

RESUMO

Herein is described the fabrication and use of a plastic multilayer 3-channel microfluidic fixture. Multilayer devices were produced by laser machining of plastic polymethylmethacrylate and polyethyleneterapthalate laminates by ablation. The fixture consisted of an array of nine individually addressable gold or gold/ITO working electrodes, and a resistive platinum heating element. Laser machining of both the fluidic pathways in the plastic laminates, and the stencil masks used for thermal evaporation to form electrode regions on the plastic laminates, enabled rapid and inexpensive implementation of design changes. Electrochemiluminescence reactions in the fixture were achieved and monitored through ITO electrodes. Electroaddressable aryl diazonium chemistry was employed to selectively pattern gold electrodes for electrochemical multianalyte DNA detection from double stranded DNA (dsDNA) samples. Electrochemical detection of dsDNA was achieved by melting of dsDNA molecules in solution with the integrated heater, allowing detection of DNA sequences specific to breast and colorectal cancers with a non-specific binding control. Following detection, the array surface could be renewed via high temperature (95 °C) stripping using the integrated heating element. This versatile and simple method for prototyping devices shows potential for further development of highly integrated, multi-functional bioanalytical devices.

12.
ACS Appl Mater Interfaces ; 2(11): 3179-84, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20945871

RESUMO

Increased mass transport due to hemispherical diffusion is observed to occur in 3D porous carbon electrodes defined by interferometric lithography. Enhanced catalytic methanol oxidation, after modifying the porous carbon with palladium nanoparticles, and uncharacteristically uniform conducting polymer deposition into the structures are demonstrated. Both examples result in two regions of hierarchical porosity that can be created to maximize surface area, via nanostructuring, within the extended porous network, while taking advantage of hemispherical diffusion through the open pores.

14.
Anal Chim Acta ; 611(1): 80-8, 2008 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-18298971

RESUMO

Patterning substrates with biological reagents is a critical component of biosensor development. Many applications require multi-analyte patterning capabilities, with a need to deposit several species reproducibly with a high degree of precision. We demonstrate a piezoelectric inkjet printing system that is capable of creating sub-millimeter (down to 150microm) patterns of aqueous and nonaqueous reagents with precise placement for biosensor applications. The size, shape, and density of the patterns may be modified by simple adjustments of the patterning parameters. Using this system, two methods of multi-analyte protein patterning for use in biosensor assays are demonstrated. The first method involves the deposition of multiple proteins directly onto a gold substrate. Specific binding of an antibody to the deposited antigen is demonstrated, although nonspecific adsorption of the antibody may limit the utility of this simple method in quantitative biosensor applications. A second, more sophisticated multi-analyte patterning method involves two sequential patterning steps, consisting of an initial deposition onto gold of a mixed thiol layer to provide oriented binding capabilities in a nonfouling background and a second deposition of multiple biotinylated proteins. Highly specific antibody binding to this patterned multi-analyte surface was demonstrated, with minimal nonspecific adsorption to the surrounding regions. Thus, this method produces high-quality, localized, and customizable sub-millimeter patterns in a nonfouling background for multi-analyte bioassay development.


Assuntos
Técnicas Biossensoriais , Complexo Antígeno-Anticorpo , Sítios de Ligação de Anticorpos , Eletrônica , Ouro/química , Proteínas/química , Reprodutibilidade dos Testes
15.
Ann N Y Acad Sci ; 1098: 335-44, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17435140

RESUMO

Saliva is an underused fluid with considerable promise for biomedical testing. Its potential is particularly great for monitoring small-molecule analytes since these are often present in saliva at concentrations that correlate well with their free levels in blood. We describe the development of a prototype diagnostic device for the rapid detection of the antiepileptic drug (AED) phenytoin in saliva. The multicomponent system includes a hand-portable surface plasmon resonance (SPR) imaging instrument and a disposable microfluidic assay card.


Assuntos
Saliva/química , Ressonância de Plasmônio de Superfície , Biomarcadores/análise , Biomarcadores/química , Biomarcadores/metabolismo , Microfluídica , Ressonância de Plasmônio de Superfície/instrumentação , Ressonância de Plasmônio de Superfície/métodos
16.
Biosens Bioelectron ; 22(9-10): 2208-15, 2007 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-17150350

RESUMO

We report the construction and characterization of a new compact surface plasmon resonance imaging instrument. Surface plasmon resonance imaging is a versatile technique for detection, quantification and visualization of biomolecular binding events which have spatial structure. The imager uses a folded light path, wide-field optics and a tilted detector to implement a high performance optical system in a volume 7 in. x 4 in. x 2 in. A bright diode light source and an image detector with fast frame rate and integrated digital signal processor enable real-time averaging of multiple images for improved signal-to-noise ratio. Operating angle of the imager is adjusted by linear translation of the light source. Imager performance is illustrated using resolution test targets, refractive index test solutions, and competition assays for the antiepileptic drug phenytoin. Microfluidic flowcells are used to enable simultaneous assay of three sample streams. Noise level of refractive index measurements was found to decrease proportional to the square root of the number of pixels averaged, reaching approximately 5 x 10(-7) refractive index units root-mean-square for 160 x 120 pixels image regions imaged for 1s. The simple, compact construction and high performance of the imager will allow the device to be readily applied to a wide range of applications.


Assuntos
Diagnóstico por Imagem/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Técnicas Analíticas Microfluídicas
17.
Nature ; 442(7101): 412-8, 2006 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-16871209

RESUMO

The developing world does not have access to many of the best medical diagnostic technologies; they were designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. Microfluidic systems allow miniaturization and integration of complex functions, which could move sophisticated diagnostic tools out of the developed-world laboratory. These systems must be inexpensive, but also accurate, reliable, rugged and well suited to the medical and social contexts of the developing world.


Assuntos
Testes Diagnósticos de Rotina/métodos , Internacionalidade , Microfluídica/métodos , Saúde Pública/métodos , Países em Desenvolvimento/economia , Testes Diagnósticos de Rotina/economia , Testes Diagnósticos de Rotina/instrumentação , Humanos , Microfluídica/economia , Microfluídica/instrumentação , Saúde Pública/tendências
18.
Lab Chip ; 3(3): 150-7, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15100766

RESUMO

This paper describes an approach for fabricating multi-layer microfluidic systems from a combination of glass and plastic materials. Methods and characterization results for the microfabrication technologies underlying the process flow are presented. The approach is used to fabricate and characterize multi-layer plastic/glass microfluidic systems containing electrical and mechanical functionality. Hot embossing, heat staking of plastics, injection molding, microstenciling of electrodes, and stereolithography were combined with conventional MEMS fabrication techniques to realize the multi-layer systems. The approach enabled the integration of multiple plastic/glass materials into a single monolithic system, provided a solution for the integration of electrical functionality throughout the system, provided a mechanism for the inclusion of microactuators such as micropumps/valves, and provided an interconnect technology for interfacing fluids and electrical components between the micro system and the macro world.


Assuntos
Vidro/química , Membranas Artificiais , Microfluídica/instrumentação , Plásticos/química , Materiais Biocompatíveis/química , Condutividade Elétrica , Desenho de Equipamento , Microeletrodos , Microscopia Eletrônica de Varredura , Fotografação/métodos , Pressão
19.
Anal Chem ; 74(6): 1211-6, 2002 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-11922286

RESUMO

A microscale thermal field-flow fractionation (micro-TFFF) system has been designed, fabricated, and characterized. Motivation for miniaturization of TFFF systems was established by examining the geometrical scaling of the fundamental TFFF theory. Miniaturization of conventional macroscale TFFF systems was made possible through utilization of micromachining technologies. Fabrication of the micro-TFFF system was discussed in detail. The micro-TFFF system was characterized for plate height versus flow rate, single-component polystyrene retention, and multicomponent polystyrene separations. Retention, thermal diffusion coefficients, and maximum diameter-based selectivity values were extracted from separation data and found comparable with macroscale TFFF system results. Retention values ranged from 0.33 to 0.46. Thermal diffusion coefficients were between 3.0 x 10(-8) and 5.4 x 10(-8) cm2/s x K. The maximum diameter-based selectivity was 1.40.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...