Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 90(11): 113502, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779410

RESUMO

Plasma assisted combustion is a very active research field due to the potential of using the technology to improve combustion efficiency and decrease pollutant emission by stabilizing lean burning flames. It has been shown in a number of studies that a small amount of electrical energy can be deposited in the flame by applying microwaves, resulting in enhanced flame propagation and thus improved flame stabilization and delayed lean blow-out. However, the effects have not yet been properly quantified since there are significant experimental challenges related to the determination of both the laminar burning velocity and the electric field strength. In the present work, a novel setup is described, where a well-defined burner system is coupled to a microwave cavity. The burner is of heat flux type, where a flat laminar flame is stabilized on a perforated burner head. The advantage of this burner for the current use is that the method and related uncertainties are well studied and quantified, and the geometry is suitable for coupling with the microwave cavity. The setup, experimental procedure, and data analysis are described in detail in this article. Laminar burning velocity for a methane-air flame at ϕ = 0.7 is determined to certify that the burner works properly in the microwave cavity. The flame is then exposed to pulsed microwaves at 1 kHz with a pulse duration of 50 µs. The laminar burning velocity at these conditions is determined to be 18.4 cm/s, which is an increase by about 12% compared to the laminar burning velocity that is measured without microwave exposure. The setup shows potential for further investigations of lean flames subjected to various microwave pulse sequences. The data are of high quality with well-defined uncertainties and are therefore suitable to use for validation of chemical kinetics models.

2.
Comput Methods Programs Biomed ; 43(1-2): 81-4, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-7956151

RESUMO

The introduction of PACS in a radiology department means that most functions that are available in the film-based system must be included. One important function is the radiology conference. The handling and application programs of digital workstations are normally not developed for demonstrations of many images in a limited time. This paper describes a workstation with specially designed software for radiology conferences. The application is separated in preparation and presentation of the cases to be demonstrated. Very fast image handling is achieved during the conference because the function is based on the principle of prefetching of the selected images. The images are presented on a large screen with high resolution. The experiences of digital radiology conferences are good. However, reference films from previous examinations create extra work because they have to be shown on the conventional lightbox.


Assuntos
Congressos como Assunto/organização & administração , Sistemas de Informação em Radiologia/organização & administração , Validação de Programas de Computador , Terminais de Computador , Humanos , Intensificação de Imagem Radiográfica , Fatores de Tempo , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...