Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sportverletz Sportschaden ; 38(1): 27-30, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38049098

RESUMO

In recent years, professional and non-professional bouldering have seen a fundamental change in movement patterns towards complex movement sequences. This is associated with increased demands on the musculoskeletal system, especially the lower extremities, which can lead to new injury patterns. In the course of our clinical work, we have already seen an increasing number of lower extremity injuries after run-and-jump sequences, with a severe one being highlighted in this case report.


Assuntos
Traumatismos em Atletas , Traumatismos da Perna , Humanos , Extremidade Inferior/lesões
2.
Eur J Radiol ; 126: 108913, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32135408

RESUMO

PURPOSE: Aim of this study was to evaluate image quality of single source dual energy CT (SSDE-CT) using split filter technique in oncologic abdominal CT. METHOD: 51 consecutive patients with newly diagnosed breast carcinoma were prospectively enrolled in this study and underwent a staging examination of the abdomen using SSDE-CT (120 kV, split filter technique, 400 ref. mAs). Inline default images (DI) and post-processed virtual monoenergetic images at 40 keV, 50 keV, 60 keV, 70 keV and 80 keV were reconstructed. Objective image quality was evaluated as contrast to noise ratio (CNR) for liver parenchyma, portal vein, spleen, pancreas, aorta and hypoattenuating liver lesions. Subjective image quality was rated on a 5-point scale. Image quality at different keV settings was analyzed in paired t-tests. RESULTS: CNR was highest at 40 keV for vessels (portal vein: 9.0, aorta: 8.8, all p < 0.001) and for upper abdominal organs (spleen: 4.8, all p < 0.001; pancreas: 2.7, all p < 0.01 except p = 0.93 for 50 keV; liver parenchyma: 3.4, all p < 0.01). Highest CNR values for hypoattenuating liver lesions were found at 40 keV (7.7, all p < 0.001). Overall subjective image quality was highest with 80 keV and DI (both 4.8, all p < 0.001). Artifacts were most pronounced at 40 keV. CONCLUSIONS: High image quality can be obtained with SSDE-CT of the abdomen. Lowest monoenergetic reconstructions provide the highest image contrast and should be used for vessel evaluation. The best trade-off between artifacts and parenchymal contrast can be obtained with 80 keV images.


Assuntos
Neoplasias da Mama/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Feminino , Humanos , Fígado/diagnóstico por imagem , Estudos Prospectivos , Radiografia Abdominal/métodos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...