1.
Comput Methods Biomech Biomed Engin ; 24(3): 320-332, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33063557

RESUMO

In total knee arthroplasty (TKA), force is transmitted into the tibia by a combined plate-stem device along with cemented or cementless stem fixation. The present work analyzes this force transmission in finite element simulations with the main aim to avoid reported postsurgical bone density reduction as a consequence of a reduced tibial bone loading. In the numerical analysis different implant materials, stem/extension lengths and implant-to-stem interface conditions are considered, from a stiff fully cemented fixation to sliding contact conditions with a low friction coefficient. The impact of these variations on bone loading changes are measured by (i) decomposing the total force into parts mediated by the plate and by the stem and by (ii) post-surgery strain energy density (SED) deviations. Based on a bionics-inspired perspective on how nature in pre-operative conditions carries out force transfer from the knee joint into the tibia, a modified implant-bone interface is suggested that alters force transmission towards physiological conditions while preserving the geometries of the standard plate-stem endoprosthesis design. The key aspect is that the axial force is predominantly transmitted through the plate into proximal bone which requires a compliant bone-stem interface as realized by sliding friction conditions at a low friction coefficient. These interface conditions avoid stress shielding almost completely, preserve pre-surgery bone loading such that bone resorption is not likely to occur.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Metais/química , Reoperação , Estresse Mecânico , Tíbia/cirurgia , Feminino , Análise de Elementos Finitos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Suporte de Carga
2.
Med Eng Phys ; 2018 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-29773487

RESUMO

The present work proposes a simple, novel fixation concept for short stem hip endoprostheses, which preserves the pre-surgery force flow through femoral bone to an unprecedented extent. It is demonstrated by finite element analyses that a standard implant model endowed with minor geometrical changes can overcome bone loading reduction and can achieve almost physiological conditions. The numerical results underpin that the key aspect of the novel, so-called "collar cortex compression concept CO4" is the direct, almost full load transmission from the implant collar to the resected femur cortex, which implies that the implant stem must be smooth and therefore interacts mainly by normal contact with the surrounding bone. For a stem endowed with surface porosity at already small areas, it is mainly the stem which transmits axial forces by shear, whereas the collar shows considerable unloading, which is the standard metaphyseal fixation. Only in the latter case the implant-bone stiffness contrast induces stress shielding, whereas for CO4 stress shielding is avoided almost completely, although the implant is made of a stiff Ti-alloy. CO4 is bionics-inspired in that it mimics force transmission at implant-bone interfaces following the natural conditions and it thereby preserves pre-surgery bone architecture as an optimized solution of nature.