Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Med Res ; 28(1): 520, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37968756

RESUMO

PURPOSE: This study aims to evaluate the digitally designed ball attachment housing in its initial retentive force and after 2 years of simulated clinical use and to compare it with the regular nylon ball attachment housing. MATERIALS AND METHODS: Twenty implants with their corresponding ball abutments (diameter 4.5 × 4.0 mm) were inserted in resin blocks. They were divided into two groups. In Group I, ten ball abutments each received their corresponding conventional attachment with nylon rings. In Group II, ten ball abutments received the novel CAD-CAM polyetheretherketone ball attachment housing. A universal testing machine was used to measure the retention force. The achieved maximum values of retention force were recorded at the beginning of the study (initial retention) and after 2 years of artificial ageing (2000 cycles of insertion and removal). Results were statistically analyzed using an independent sample T test. RESULTS: The PEEK attachment housing showed high retention forces (25.12 ± 0.99 N) compared to the conventional attachment with a nylon ring (15.76 ± 0.93 N) in the initial dislodgement test. There was a statistically significant difference in mean retention at the initial retention test and after 2 years of stimulated usage between the two studied groups, p = 0.000. CONCLUSIONS: Within the limitations of this study, the novel CAD-CAM-PEEK attachment showed high retention characteristics compared to the conventional attachment with nylon rings, initially and after simulated long-term use.


Assuntos
Habitação , Nylons , Humanos , Retenção de Dentadura/métodos , Revestimento de Dentadura , Teste de Materiais , Polietilenoglicóis , Cetonas , Desenho Assistido por Computador
2.
Implant Dent ; 14(1): 30-5, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15764942

RESUMO

Slippage of an implant into the maxillary sinus is an exceptional complication that may occur during immediate implant placement. In this study, removal of a displaced implant into the maxillary sinus with the aid of endoscopy via buccal window approach is reported. Management of such a rare complication is also addressed.


Assuntos
Implantes Dentários , Endoscopia/métodos , Corpos Estranhos/cirurgia , Seio Maxilar , Adulto , Feminino , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/etiologia , Humanos , Dente Molar , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...