Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 206: 578-587, 2019 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-30193200

RESUMO

Multivariate strategy was applied for setting a fluorescent technique for the determination of three fluoroquinolones: norfloxacin (NOR), levofloxacin (LEV) and lomefloxacin (LOM) in their pure powder and dosage forms. Based on their known interaction with lanthanides, and augmented fluorescence intensity obtained by antenna effect at λex/λem = 314/553, 312/553 and 310/556 for NOR, LEV and LOM, respectively, the current research was scrutinized. Four continuous factors were selected for study in the screening step by means of Plackett-Burman Design, where temperature factor was excluded for being non-significant and the other factors as volume of metal ion solution, pH and reaction time were evaluated through Central Composite Design. 3-D surfaces demonstrations and 2-D contour plots designated the factors interactions followed by optimization plots, which defined the best blend for factors conjunction. pH factor was the chief motor force affecting the response as the number of coordinated ligands formed depends on the pH, whereas 1:2 complex is the main species at higher pH values followed by the volume of metal ion solution and ended by little effect of the reaction time. Model verification was monitored, which showed the model superiority for the three fluoroquinolones, where all target points tested were in good agreement with the predicted ones. The linear range for the tested drugs were found to be 0.090-1.280 µg/mL for NOR, 0.068-1.448 µg/mL for LEV and 0.077-1.552 µg/mL in case of LOM, thus approving the suitability of this method for Quality Control testing. Furthermore, applying these conditions to test the fluoroquinolones in their pharmaceuticals was done as well as intra and inter-day effects as to confirm the validity of this technique for routine analysis. Recovery % and RSD were found to be 99.958 ±â€¯0.797, 99.887 ±â€¯0.935 and 100.427 ±â€¯0.698 for NOR, LEV and LOM respectively in their pure powder. While it was calculated to be 100.200 ±â€¯0.785, 100.530 ±â€¯0.396 and 100.620 ±â€¯0.896 for NOR, LEV and LOM in their corresponding dosage forms. This excellent precision and accuracy obtained in results impulse it to be one of the most appropriate methods for further analysis.


Assuntos
Fluoroquinolonas/análise , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Espectrometria de Fluorescência/métodos
2.
Anal Sci ; 26(4): 437-42, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20410565

RESUMO

Two ion-selective sensors of the plastic membrane type were prepared for the determination of oxybutynin hydrochloride (OxCl). They depend on the incorporation of the ion-associates with phosphotungestic acid or phosphomolybdic acid in a PVC matrix. A comparative study is made between their performance characteristics in batch and FIA conditions. The sensors have nearly the same usable concentration, temperature and pH range. They have a wide range of selectivity and can be applied for the determination of the relevant drug with nearly the same precision and accuracy in vitro. Dissolution testing was applied using the sensors; this offers a simple, rapid, cheap way out of sophisticated and high cost instruments used in the pharmacopeial method using HPLC. The investigated drug was determined in its pure and pharmaceutical preparations. The results were accurate and precise, as indicated by the recovery values and coefficients of variation.


Assuntos
Técnicas de Química Analítica/instrumentação , Ácidos Mandélicos/análise , Ácidos Mandélicos/química , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Análise de Injeção de Fluxo , Concentração de Íons de Hidrogênio , Membranas Artificiais , Molibdênio/química , Ácidos Fosfóricos/química , Ácido Fosfotúngstico/química , Reprodutibilidade dos Testes , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...