Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 255, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872120

RESUMO

BACKGROUND: Vitreoretinal lymphoma (VRL) is a rare intraocular malignancy that poses a diagnostic challenge due to the non-specific clinical presentation that resembles uveitis. The use of spectral domain optical coherence tomography (SD-OCT) has emerged as a valuable imaging tool to characterize VRL. Therefore, we sought to determine the specific OCT features in VRL compared to the uveitides. METHODS: Retrospective chart review of patients who were seen at Mayo Clinic from January 1, 2010 through December 31, 2022. The medical records and SD-OCT images at time of initial presentation were reviewed in patients with biopsy-proven VRL, intermediate uveitis, or biopsy-confirmed sarcoid posterior uveitis. Patients with VRL or similar uveitides including intermediate uveitis or sarcoid posterior uveitis were included. RESULTS: There were 95 eyes of 56 patients in the VRL group and 86 eyes of 45 patients in the uveitis group, of whom 15 (33.3%) were diagnosed with intermediate uveitis and 30 (66.7%) with sarcoid chorioretinitis. The SD-OCT features more commonly seen at initial presentation in VRL patients (vs. uveitis) included preretinal deposits (31.6% vs. 9.3%, p = 0.002), intraretinal infiltrates (34% vs. 3.5%, p < 0.001), inner retinal hyperreflective spots (15.8% vs. 0%, p < 0.001), outer retinal atrophy (22.1% vs. 2.3%, p < 0.001), subretinal focal deposits (21.1% vs. 4.7%, p = 0.001), retinal pigmented epithelium (RPE) changes (49.5% vs. 3.5%, p < 0.001), and sub-RPE deposits (34.7% vs. 0%, p < 0.001). Features more frequently seen in uveitis included epiretinal membrane (ERM) (82.6% vs. 44.2%, p < 0.001), central macular thickening (95.3% vs. 51.6%, p < 0.001), cystoid macular edema (36% vs. 11.7%, p < 0.001), subretinal fluid (16.3% vs 6.4%, p = 0.04), and subfoveal fluid (16.3% vs. 3.2%, p = 0.003). Multivariate regression analysis controlling for age and sex showed absence of ERM (OR 0.14 [0.04,0.41], p < 0.001) and absence of central macular thickening (OR 0.03 [0,0.15], p = 0.02) were associated with VRL as opposed to uveitis. CONCLUSION: OCT features most predictive of VRL (vs. uveitis) included absence of ERM and central macular thickening.


Assuntos
Neoplasias da Retina , Tomografia de Coerência Óptica , Uveíte , Corpo Vítreo , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Neoplasias da Retina/diagnóstico , Neoplasias da Retina/diagnóstico por imagem , Idoso , Corpo Vítreo/patologia , Corpo Vítreo/diagnóstico por imagem , Uveíte/diagnóstico , Adulto , Linfoma Intraocular/diagnóstico , Acuidade Visual , Diagnóstico Diferencial , Idoso de 80 Anos ou mais
2.
J Glaucoma ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38747724

RESUMO

PRECIS: This meta-analysis examines the comparative efficacy of phacoemulsification with and without Kahook Dual Blade Goniotomy in individuals with glaucoma and cataract, aiming to elucidate optimal surgical approaches for coexisting conditions. PURPOSE: The purpose of this current study is to compare the effect of combining Kahook Dual Blade (KDB) goniotomy with phacoemulsification versus phacoemulsification alone on intraocular pressure (IOP) and medication reduction in patients with glaucoma and cataract. METHODS: We conducted a systematic review and meta-analysis utilizing computer databases, including Embase (OVID), MEDLINE (OVID and PubMed), CINHAL (EBSCO), and the Cochrane Library (Wiley). We included studies examining the IOP-lowering effect of KDB goniotomy combined with phacoemulsification and studies that examined the IOP-lowering effect of phacoemulsification alone in patients with open angle glaucoma or ocular hypertension. The mean reduction of IOP and the reduction in topical glaucoma eye drops after surgery were determined. RESULTS: A total of 26 studies were included reporting on 1659 patients, 684 patients underwent phacoemulsification alone and 975 underwent combined phacoemulsification and KDB goniotomy. A 9.62% IOP reduction from baseline occurred following phacoemulsification as a solo procedure compared to 22.74% following combined KDB goniotomy with phacoemulsification. Similarly, the combination of the procedures caused a significant drop in the mean number of glaucoma eye drops used (mean reduction=1.35, 95% CI [1.08, 1.61]) compared to phacoemulsification alone (mean reduction=0.36, 95% CI [0.06, 0.66]). Funnel plots suggested the absence of publication bias. CONCLUSION: Both phacoemulsification alone or combined with KDB goniotomy result in a significant decrease in post-op IOP and topical glaucoma eye drops. The combination of these two procedures outperforms phacoemulsification alone in terms of both parameters.

3.
Ophthalmic Res ; 66(1): 1020-1029, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37245507

RESUMO

BACKGROUND: The iStent (Glaukos Corporation; Laguna Hills, CA, USA) is one of the minimally invasive glaucoma devices. It can be inserted at the time of phacoemulsification or as a stand-alone procedure to lower the intraocular pressure (IOP). OBJECTIVE: Our aim was to conduct a systematic review and meta-analysis comparing the effect of iStent insertion at the time of phacoemulsification with phacoemulsification alone in patients with ocular hypertension or open-angle glaucoma. METHODS: We searched EMBASE, MEDLINE (OVID and PubMed), CINAHL, and Cochrane Library for articles published between 2008 and June 2022 (PRISMA 2020 for the checklist). Studies comparing the IOP-lowering effect of iStent with phacoemulsification versus phacoemulsification alone were included. The endpoints were IOP reduction (IOPR) and the mean reduction in the number of glaucoma drops. A quality-effects model was used to compare both surgical groups. RESULTS: Ten studies were included, reporting on 1,453 eyes. Eight hundred fifty three eyes had the combined iStent and phacoemulsification, and 600 eyes underwent phacoemulsification alone. IOPR was higher in the combined surgery at of 4.7 ± 2 mm Hg compared to 2.8 ± 1.9 mm Hg in phacoemulsification alone. A greater decrease in postoperative eye drops was noted in the combined group having a decrease of 1.2 ± 0.3 eye drops versus of 0.6 ± 0.6 drops in isolated phacoemulsification. The quality effect model showed an IOPR weighted mean difference (WMD) of 1.22 mm Hg (confidence interval [CI]: [-0.43, 2.87]; Q = 315.64; p < 0.01; I2 = 97%) and decreased eye drops WMD 0.42 drops (CI: [0.22, 0.62]; Q = 42.6; p < 0.01; I2 = 84%) between both surgical groups. Subgroup analysis shows that the new generation iStent may be more effective in reducing IOP. CONCLUSION: iStent has a synergetic effect with phacoemulsification. The reduction of IOP and glaucoma eye drops was higher when iStent is combined with phacoemulsification compared with isolated phacoemulsification.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Facoemulsificação , Humanos , Facoemulsificação/métodos , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma/cirurgia , Pressão Intraocular , Malha Trabecular/cirurgia , Soluções Oftálmicas
4.
Cureus ; 13(11): e19552, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34917434

RESUMO

Purpose To report the response of keratoconus (KC) and post-LASIK ectasia (referred to as "ectasia") to the corneal crosslinking (CXL) and to compare the rate of progression between KC and ectasia at three years. Methods A retrospective cohort study of patients undergoing CXL for either KC or ectasia. Fifty-four eyes (31 patients) with ectasia and 111 eyes (67 patients) with KC were included in the study. Corrected distance visual acuities (CDVA), refraction, keratometry (K), and pachymetry were followed up for three years. Simultaneous photorefractive keratectomy (PRK) and CXL were performed on 20 KC and 20 ectasia eyes. Intrastromal Corneal Ring Segments (ICRS) were performed on 51 KC and six ectasia eyes. Results In KC, CDVA, spherical equivalence, sphere, cylinder, and mean K improved at three years post-CXL (p-value<0.05), but these values improved without reaching a statistical significance in ectasia(p-values <0.05). 12 of 54 eyes with ectasia (22.2%) and 4 of 111 eyes (3.6%) with KC had progression post CXL(p-value:0.0001). Ectasia patients diagnosed with progression were older at presentation (36.1 years) than non-progressive ectasia patients (31 years) (p-value 0.02) and also older than KC patients. Sub-analysis excluding PRK and ICRS cases showed that there was an improvement in mean sphere (from -5.23±4.2D to-4.46±3.89D) (p-value 0.03) cylinder (from 2.54 ± 1.68D to 1.97 ± 1.51D) (p-value 0.03) mean keratometry (from 46.81 ± 3.78D to 46.01 ± 3.25D) (p-value 0.006) in KC patients 3 years post CXL (40 patients). Compared to baseline, all the mean refractive and topographic variables deteriorated at three years post CXL in ectasia (28 patients) (p-value>0.05). Also, 2 of 40 patients with KC (5%) vs. 7 of 28 patients with ectasia (25%) had progression three years post-CXL, and the difference between both groups remained statistically significant(p-value 0.027). Conclusion Eyes with post-LASIK ectasia seem to be less responsive to CXL than KC.

5.
JAMA Ophthalmol ; 139(9): 937-943, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34351374

RESUMO

IMPORTANCE: A review of the injury patterns, treatment strategies, and responding physicians' experience during the Port of Beirut blast may help guide future ophthalmic disaster response plans. OBJECTIVE: To present the ophthalmic injuries and difficulties encountered as a result of the Port of Beirut blast on August 4, 2020. DESIGN, SETTING, AND PARTICIPANTS: A retrospective medical record review of all patients who presented to the emergency department and 13 ophthalmology outpatient clinics at the American University of Beirut Medical Center for treatment of ophthalmic injuries sustained from the explosion in Port of Beirut, Beirut, Lebanon, from August 4 to the end of November 2020. Patients were identified from emergency records, outpatient records, and operative reports. MAIN OUTCOMES AND MEASURES: Types of ocular injuries, final best-corrected visual acuity, and need for surgical intervention were evaluated. Visual acuity was measured with correction based on noncycloplegic refraction using the Snellen medical record. EXPOSURES: Ocular or ocular adnexal injuries sustained from the Port of Beirut explosion. RESULTS: A total of 39 blast survivors with ocular injuries were included in this study. Twenty-two patients presented with ocular injuries on the day of the blast, and 17 patients presented within the following 3 months to the ophthalmology clinics for a total of 48 eyes of 39 patients were treated secondary to the blast. Thirty-five patients (89.6%) were adults, and 24 (61.5%) were female. A total of 21 patients (53.8%) required surgical intervention, more than half of which were urgently requested on the same day of presentation (14 [35.9%]). Most eye injuries were caused by debris and shrapnel from shattered glass leading to surface injury (26 [54.2%]), eyelid lacerations (20 [41.6%]), orbital fractures (14 [29.2%]), brow lacerations (10 [20.8%]), hyphema (9 [18.8%]), open globe injuries (10 [20.8%]), and other global injuries. Only 7 injured eyes (14.5%) had a final best-corrected visual acuity of less than 20/200, including all 4 open globe injuries with primary no light perception (8.3%) requiring enucleation or evisceration. CONCLUSIONS AND RELEVANCE: In the aftermath of the Port of Beirut explosion, a review of the ophthalmic injuries showed a predominance of shrapnel-based injuries, many of which had a delayed presentation owing to the strain placed on health care services. Reverting to basic approaches was necessary in the context of a malfunctioning electronic medical record system.


Assuntos
Traumatismos por Explosões , Traumatismos Oculares , Lacerações , Adulto , Traumatismos por Explosões/epidemiologia , Traumatismos por Explosões/etiologia , Traumatismos por Explosões/cirurgia , Explosões , Traumatismos Oculares/epidemiologia , Traumatismos Oculares/etiologia , Traumatismos Oculares/cirurgia , Pálpebras , Feminino , Humanos , Lacerações/complicações , Masculino , Estudos Retrospectivos
6.
Clin Ophthalmol ; 14: 2373-2381, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32903901

RESUMO

PURPOSE: To determine the patient-related factors that contribute to surgeon stress during phacoemulsification cataract extraction (PCE) performed under unassisted topical anesthesia. METHODS: This is a prospective study of perceived surgeon stress during phacoemulsification by a single surgeon of consecutive patients undergoing PCE. At the conclusion of each procedure, the surgeon recorded the perceived stress according to the following three indices: surgeon score, qualitative score (yes or no), and total score (sum of itemized causes of stress). Patient variables included in the analysis included gender, age, diabetes mellitus, morbid obesity, intake of oral alpha blockers, floppy iris, laterality, pseudo-exfoliation, intraocular lens power, and initial visual acuity. RESULTS: During the 10-year study, 1097 eyes underwent surgery. The following patient variables were seen frequently: floppy iris syndrome (92), pseudo-exfoliation (72), and morbid obesity (36). Surgeon identified stress was reported after 250 procedures. On multivariable analysis, the following patient characteristics were associated with surgeon stress: age >80 years; morbid obesity; floppy iris syndrome; severe nuclear sclerosis; and poor baseline distance corrected visual acuity. CONCLUSION: Several ocular and systemic patient-related characteristics contribute to surgeon stress during PCE.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...