Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Drug Saf ; 13(1): 12-20, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29359677

RESUMO

INTRODUCTION: Due to the chaos in the legislation in the Middle East, male enhancement nutraceuticals may be sold without any registration or evaluation. These products need to be evaluated with respect to safety and efficacy. Furthermore, cultural and social considerations in the Middle East prevent the use of international evaluations schemes for erectile dysfunction. AIM: Evaluating the safety and efficacy parameters of generic and nutraceutical products for erectile dysfunction in the Middle East through a custom-designed, representable and simple system tailored to the regional culture. METHODS: 74 healthy male volunteers were enrolled into a comparative, simple randomized, single dose, double blind, and crossover clinical study incorporated with a tailored-designed questionnaire. Safety assessment included laboratory analysis for liver functions and measuring blood pressure. MAIN OUTCOME MEASURES: Subjective data regarding safety and efficacy were assessed from the validated questionnaire. Blood pressure was measured. Blood samples were collected to assess the drug/adulterants concentration and liver and kidney functions. RESULTS: All tested nutraceuticals showed undeclared Sildenafil citrate in patients. Questionnaire results showed high inter-patient variability with respect to efficacy and comparable safety profile compared to Viagra®. CONCLUSION: The validated tailored-designed questionnaire effectively assessed the efficacy and safety of male enhancement products. The male enhancement nutraceuticals, sold in Egypt, claimed to be 100% natural are adulterated and of questionable safety profile.


Assuntos
Suplementos Nutricionais/análise , Contaminação de Medicamentos , Medicamentos Genéricos/análise , Disfunção Erétil/sangue , Disfunção Erétil/epidemiologia , Citrato de Sildenafila/análise , Adulto , Estudos Cross-Over , Método Duplo-Cego , Contaminação de Medicamentos/prevenção & controle , Medicamentos Genéricos/metabolismo , Medicamentos Genéricos/uso terapêutico , Egito/epidemiologia , Disfunção Erétil/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Fosfodiesterase 5/análise , Inibidores da Fosfodiesterase 5/sangue , Inibidores da Fosfodiesterase 5/uso terapêutico , Citrato de Sildenafila/sangue , Citrato de Sildenafila/uso terapêutico , Resultado do Tratamento
2.
Oncotarget ; 8(48): 83734-83744, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-29137378

RESUMO

BACKGROUND: Drug and antibody delivery to brain metastases has been highly debated in the literature. The blood-tumor barrier (BTB) is more permeable than the blood-brain barrier (BBB), and has shown to have highly functioning efflux transporters and barrier properties, which limits delivery of targeted therapies. METHODS: We characterized the permeability of 125I-trastuzumab in an in-vivo, and fluorescent trastuzumab-Rhodamine123 (t-Rho123) in a novel microfluidic in-vitro, BBB and BTB brain metastases of breast cancer model. In-vivo: Human MDA-MB-231-HER2+ metastatic breast cancer cells were grown and maintained under static conditions. Cells were harvested at 80% confluency and prepped for intra-cardiac injection into 20 homozygous female Nu/Nu mice. In-vitro: In a microfluidic device (SynVivo), human umbilical vein endothelial cells were grown and maintained under shear stress conditions in the outer compartment and co-cultured with CTX-TNA2 rat brain astrocytes (BBB) or Met-1 metastatic HER2+ murine breast cancer cells (BTB), which were maintained in the central compartment under static conditions. RESULTS: Tissue distribution of 125I-trastuzumab revealed only ~3% of injected dose reached normal brain, with ~5% of injected dose reaching brain tumors. No clear correlation was observed between size of metastases and the amount of 125I-trastuzumab localized in-vivo. This heterogeneity was paralleled in-vitro, where the distribution of t-Rho123 from the outer chamber to the central chamber of the microfluidic device was qualitatively and quantitatively analyzed over time. The rate of t-Rho123 linear uptake in the BBB (0.27 ± 0.33 × 104) and BTB (1.29 ± 0.93 × 104) showed to be significantly greater than 0 (p < 0.05). The BTB devices showed significant heterogenetic tendencies, as seen in in-vivo. CONCLUSIONS: This study is one of the first studies to measure antibody movement across the blood-brain and blood-tumor barriers, and demonstrates that, though in small and most likely not efficacious quantities, trastuzumab does cross the blood-brain and blood-tumor barriers.

3.
Healthc Inform Res ; 21(4): 315-20, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26618039

RESUMO

OBJECTIVES: The new wave of wireless technologies, fitness trackers, and body sensor devices can have great impact on healthcare systems and the quality of life. However, there have not been enough studies to prove the accuracy and precision of these trackers. The objective of this study was to evaluate the accuracy, precision, and overall performance of seventeen wearable devices currently available compared with direct observation of step counts and heart rate monitoring. METHODS: Each participant in this study used three accelerometers at a time, running the three corresponding applications of each tracker on an Android or iOS device simultaneously. Each participant was instructed to walk 200, 500, and 1,000 steps. Each set was repeated 40 times. Data was recorded after each trial, and the mean step count, standard deviation, accuracy, and precision were estimated for each tracker. Heart rate was measured by all trackers (if applicable), which support heart rate monitoring, and compared to a positive control, the Onyx Vantage 9590 professional clinical pulse oximeter. RESULTS: The accuracy of the tested products ranged between 79.8% and 99.1%, while the coefficient of variation (precision) ranged between 4% and 17.5%. MisFit Shine showed the highest accuracy and precision (along with Qualcomm Toq), while Samsung Gear 2 showed the lowest accuracy, and Jawbone UP showed the lowest precision. However, Xiaomi Mi band showed the best package compared to its price. CONCLUSIONS: The accuracy and precision of the selected fitness trackers are reasonable and can indicate the average level of activity and thus average energy expenditure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...