Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Occup Environ Hyg ; 12(4): 222-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25437276

RESUMO

Previous research has studied the impact of Level II concealed soft body armor (SBA) on the augmentation of heat storage in a hot environment simulating a typical summer day in the southeastern United States (wet bulb globe temperature [WBGT] = 30°C) and noted a significant difference between macro- and micro-WBGTs. The purpose of this study was to characterize the microclimate (micro-WBGT) under a concealed Level II SBA during 60 min of moderately intense work at two separate macro-WBGTs (26°C and 30°C), and to establish WBGT corrections to allow prediction of heat strain in an individual wearing a concealed Level II SBA. A single trial was performed with nine volunteers (27 ± 4 years) outfitted with a simulated standard law enforcement uniform and a traditional concealed Level II SBA, in a moderately warm environment (WBGT = 26°C). Each participant performed cycles of 12 min of walking (1.25 L · min(-1)) and 3 min of arm curls (14.3 kg, 0.6 L · min(-1)) with a 5 min rest after every other cycle, for a total of 60 minutes. This trial was compared to an identical previously completed 60-min work bout at 30°C. A two-way repeated measures ANOVA with Post hoc Bonferroni and paired samples t-test analysis was conducted. A greater difference between macro- micro-WBGTs existed at 26°C compared to the 30°C macro-WBGT. Under these conditions, a moderate work in Level II SBA requires a WBGT correction of 8.9°C and 6.2°C at macro-WBGTs of 26°C and 30°C, respectively. A modified simple linear regression prediction model was established for mean Micro-WBGT for each macro-WBGTs after the plateau point at the 30 min mark. The derivation regressions at 26°C (R(2) = 0.99), and 30°C (R(2) = 0.99) indicate that micro-WBGT could be predicted for each 15 minutes time at both macro-WBGTs tested for individuals doing moderate intensity (300 Kcals · hr(-1)) work wearing concealed Level II SBA.


Assuntos
Exposição Ocupacional , Roupa de Proteção , Adulto , Temperatura Corporal/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Esforço Físico/fisiologia , Polícia , Sudeste dos Estados Unidos , Temperatura
2.
J Occup Environ Hyg ; 11(2): 93-100, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24369931

RESUMO

Concealed soft body armor inhibits convective and evaporative heat loss and increases heat storage, especially in hot environments. One option to potentially mitigate heat storage is to promote airflow under the soft body armor. The purpose of this study was to evaluate the effect of ambient air induction (∼100 liters per minute) on heat strain while wearing concealed soft body armor in a hot environment (wet bulb globe temperature = 30°C). A counter-balanced, repeated measures protocol was performed with nine healthy male volunteers. Participants were fitted with either a traditional or modified Level II concealed soft body armor. Participants performed cycles of 12 min of walking (1.25 liters per minute) and 3 min of arm curls (0.6 liters per minute) for a total of 60 min. Two-way repeated measures ANOVA was used to assess the mean differences in physiological measures (rectal temperature, heart rate, micro-environment [temperature and relative humidity]). Post hoc Bonferroni analysis and paired samples t-tests (alpha = 0.01) were conducted on omnibus significant findings. Perceptual measures (perceived exertion, thermal comfort) were analyzed using Wilcoxon Signed Ranks Tests. Modification led to an improvement in perceived exertion at 45 min (MOD: 10 ± 1; CON: 11 ± 2; p ≤ 0.001) and 60 min (MOD: 10 ± 2; CON: 12 ± 2; p ≤ 0.001) and a reduction in micro-environment temperature in MOD (1.0 ± 0.2°C, p = 0.03) compared to CON. Modification did not attenuate change in rectal temperature or heart rate (p < 0.01) during 60-min work bout. Change in rectal temperature approached significance between MOD and CON at the end of the work bout (MOD: 0.4 ± 0.2°C; CON: 0.7 ± 0.3°C; p = 0.048). The slope of rectal temperature was significantly greater (p = 0.04) under CON compared to MOD. These data suggest that air induction may provide small benefits while wearing concealed soft body armor, though improvements are needed to lessen physiological strain.


Assuntos
Temperatura Corporal , Roupa de Proteção , Adulto , Regulação da Temperatura Corporal , Metabolismo Energético , Frequência Cardíaca , Humanos , Masculino , Exposição Ocupacional , Polícia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...