Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-17354803

RESUMO

Acute rejection is the most common reason of graft failure after kidney transplantation, and early detection is crucial to survive the transplanted kidney function. In this paper, we introduce a new approach for the automatic classification of normal and acute rejection transplants from Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI). The proposed algorithm consists of three main steps; the first step isolates the kidney from the surrounding anatomical structures by evolving a deformable model based on two density functions; the first function describes the distribution of the gray level inside and outside the kidney region and the second function describes the prior shape of the kidney. In the second step, a new nonrigid registration approach is employed to account for the motion of the kidney due to patient breathing. To validate our registration approach, we use a simulation of deformations based on biomechanical modelling of the kidney tissue using the finite element method (F.E.M.). Finally, the perfusion curves that show the transportation of the contrast agent into the tissue are obtained from the cortex and used in the classification of normal and acute rejection transplants. Applications of the proposed approach yield promising results that would, in the near future, replace the use of current technologies such as nuclear imaging and ultrasonography, which are not specific enough to determine the type of kidney dysfunction.


Assuntos
Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Nefropatias/patologia , Rim/patologia , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Inteligência Artificial , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
2.
Med Image Comput Comput Assist Interv ; 9(Pt 2): 799-806, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17354846

RESUMO

A new physically justified adaptive probabilistic model of blood vessels on magnetic resonance angiography (MRA) images is proposed. The model accounts for both laminar (for normal subjects) and turbulent blood flow (in abnormal cases like anemia or stenosis) and results in a fast algorithm for extracting a 3D cerebrovascular system from the MRA data. Experiments with synthetic and 50 real data sets confirm the high accuracy of the proposed approach.


Assuntos
Algoritmos , Inteligência Artificial , Vasos Sanguíneos/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Simulação por Computador , Humanos , Modelos Cardiovasculares , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Artigo em Inglês | MEDLINE | ID: mdl-17354947

RESUMO

To more accurately separate each pulmonary nodule from its background in a low dose computer tomography (LDCT) chest image, two new adaptive probability models of visual appearance of small 2D and large 3D pulmonary nodules are used to control evolution of deformable boundaries. The appearance prior is modeled with a translation and rotation invariant Markov-Gibbs random field of voxel intensities with pairwise interaction analytically identified from a set of training nodules. Appearance of the nodules and their background in a current multi-modal chest image is also represented with a marginal probability distribution of voxel intensities. The nodule appearance model is isolated from the mixed distribution using its close approximation with a linear combination of discrete Gaussians. Experiments with real LDCT chest images confirm high accuracy of the proposed approach.


Assuntos
Inteligência Artificial , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Simulação por Computador , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Biológicos , Modelos Estatísticos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Artigo em Inglês | MEDLINE | ID: mdl-16686036

RESUMO

A novel shape based segmentation approach is proposed by modifying the external energy component of a deformable model. The proposed external energy component depends not only on the gray level of the images but also on the shape information which is obtained from the signed distance maps of objects in a given data set. The gray level distribution and the signed distance map of the points inside and outside the object of interest are accurately estimated by modelling the empirical density function with a linear combination of discrete Gaussians (LCDG) with positive and negative components. Experimental results on the segmentation of the kidneys from low-contrast DCE-MRI and on the segmentation of the ventricles from brain MRI's show how the approach is accurate in segmenting 2-D and 3-D data sets. The 2D results for the kidney segmentation have been validated by a radiologist and the 3D results of the ventricle segmentation have been validated with a geometrical phantom.


Assuntos
Algoritmos , Inteligência Artificial , Encéfalo/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Rim/anatomia & histologia , Reconhecimento Automatizado de Padrão/métodos , Encéfalo/fisiologia , Simulação por Computador , Elasticidade , Humanos , Aumento da Imagem/métodos , Rim/fisiologia , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Artigo em Inglês | MEDLINE | ID: mdl-16685910

RESUMO

Automatic diagnosis of lung nodules for early detection of lung cancer is the goal of a number of screening studies worldwide. With the improvements in resolution and scanning time of low dose chest CT scanners, nodule detection and identification is continuously improving. In this paper we describe the latest improvements introduced by our group in automatic detection of lung nodules. We introduce a new template for nodule detection using level sets which describes various physical nodules irrespective of shape, size and distribution of gray levels. The template parameters are estimated automatically from the segmented data (after the first two steps of our CAD system for automatic nodule detection) - no a priori learning of the parameters density function is needed. We show quantitatively that this template modeling approach drastically reduces the number of false positives in the nodule detection (the third step of our CAD system for automatic nodule detection), thus improving the overall accuracy of CAD systems. We compare the performance of this approach with other approaches in the literature and with respect to human experts. The impact of the new template model includes: 1) flexibility with respect to nodule topology - thus various nodules can be detected simultaneously by the same technique; 2) automatic parameter estimation of the nodule models using the gray level information of the segmented data; and 3) the ability to provide exhaustive search for all the possible nodules in the scan without excessive processing time - this provides an enhanced accuracy of the CAD system without increase in the overall diagnosis time.


Assuntos
Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Inteligência Artificial , Desenho Assistido por Computador , Humanos , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/diagnóstico por imagem , Modelos Biológicos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Nódulo Pulmonar Solitário/classificação , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...