Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 12(17)2023 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-37685574

RESUMO

An accurate impression is vital during prosthodontic rehabilitation. Digital scanning has become an alternative to conventional impressions. This study compares conventional preliminary impression techniques with digital scanning, evaluating the efficiency, treatment comfort, and trueness. Impressions of 28 patients were taken using conventional and digital techniques. The efficiency of both impression techniques was evaluated by measuring the mean working time. A visual analog scale questionnaire (1-10) was used to appreciate the participants' perceptions of discomfort. Morphometric measurements, which were carried out to determine the differences between the casts, were made on the buccolingual cross sections of teeth 11 and 31 and the distolingual and mesiobuccal cusp tips of each first molar. The total treatment time was 75.5 min for conventional and 12 min for digital impressions. The patients scored a mean discomfort assessment of 6.66 for conventional and 9.03 for digital scanning. No significant differences existed between the examined areas (p < 0.05, Wilcoxon and Mann-Whitney tests) of the digital casts obtained by both techniques. The intraoral scan can be considered as an alternative to conventional preliminary impressions for performing study model analysis during orthodontic treatment planning. The digital impression is more comfortable and accepted by the patients than the conventional impression and has a shorter working time.

2.
Rev Sci Instrum ; 93(7): 073301, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35922328

RESUMO

The calibration of an ion detection system was carried out for protons and carbon ions from a few tens of keV up to about 1 MeV energies. A Thomson spectrometer deflecting the particle beam accelerated from a laser plasma creates the ion spectra on a phosphor screen behind a micro-channel plate (MCP), which are recorded by a camera. During calibration, the ion spectra simultaneously hit the slotted CR-39 track detector installed in front of the MCP and, passing through the adjacent CR-39 stripes, the MCP. The calibration provides the ratio of the interpolated values between two consecutive stripes of the camera signal and the total number of particles recorded on the corresponding stripe of CR-39. The efficiency of proton detection by CR-39 was also measured in a conventional accelerator beam and found to drop by 20% below 100 keV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...