Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq Bras Oftalmol ; 69(3): 309-12, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16936950

RESUMO

PURPOSE: To compare the safety and efficacy of human preserved amniotic membrane (AM) in the trabeculectomy for treatment of primary open-angle glaucoma. METHODS: A prospective, randomized clinical trial compared primary trabeculectomy with amniotic membrane (study group) and without amniotic membrane (control group) in the treatment of the glaucoma. Intraocular pressure (IOP), number of glaucoma medications and appearance of the bleb were compared between the two groups. Thirty-two patients divided into two groups of 16 patients were followed for a period of 12 months. RESULTS: The difference of the mean postoperative intraocular pressure between groups was not statistically significant (15.19 +/- 3.33 in the control group and 12.81 +/- 2.48 in the study group p=0.297) at one year follow-up. Postoperative number of medications decreased in both groups (p<0.001 and p=0.007, study group and control respectively). At the end of a 12-month follow-up period, nine eyes (56.25%) showed thin, avascular blebs in the study group as compared to only one eye (6.25%) in the control group. CONCLUSIONS: Trabeculectomy with amniotic membrane and standard trabeculectomy promote lower postoperative intraocular pressure although results showed no statistically significant difference between groups regarding postoperative intraocular pressure after one year follow-up.


Assuntos
Âmnio/transplante , Glaucoma/cirurgia , Trabeculectomia/métodos , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Pressão Intraocular , Masculino , Projetos Piloto , Estudos Prospectivos , Trabeculectomia/efeitos adversos , Resultado do Tratamento
2.
Arq. bras. oftalmol ; 69(3): 309-312, maio-jun. 2006. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-433791

RESUMO

OBJETIVO: Comparar a eficácia e a segurança do uso da membrana amniótica (MA) na trabeculectomia para o tratamento cirúrgico do glaucoma primário de ângulo aberto. MÉTODOS: Estudo prospectivo aberto, randomizado, grupos paralelos de tratamento. Trinta e dois pacientes com indicação de tratamento cirúrgico para glaucoma foram selecionados e aleatoriamente divididos em dois grupos. O primeiro grupo foi submetido a trabeculectomia com o uso intra-operatório da membrana amniótica (grupo estudo) e o segundo grupo foi submetido a trabeculectomia sem o uso da membrana amniótica (grupo controle) comparando o efeito redutor da pressão intra-ocular, número de medicações e aparência da bolha filtrante. Trinta e dois pacientes divididos em dois grupos de 16 pacientes foram acompanhados por 12 meses. RESULTADOS: A média das pressões pós-operatórias no grupo da membrana amniótica 12,81± 2,48 e no grupo controle 15,19±3,33 não apresentaram diferença estatisticamente significante no seguimento de um ano (p=0,297). O número de medicações pós-operatórias diminuiu nos dois grupos (p<0,001 e p=0,007 grupo estudo e grupo controle respectivamente). No final de 12 meses de pós-operatório nove olhos (56,25%) apresentaram bolhas finas e avasculares no grupo estudo comparando com apenas um olho (6,25%) do grupo controle. CONCLUSÃO: A trabeculectomia com membrana amniótica e a trabeculectomia simples mostraram redução da pressão intra-ocular no pós-operatório, embora a diferença entre elas não seja estatisticamente significante.


Assuntos
Humanos , Masculino , Feminino , Âmnio/transplante , Glaucoma/cirurgia , Trabeculectomia/métodos , Estudos de Casos e Controles , Seguimentos , Pressão Intraocular , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Trabeculectomia/efeitos adversos
3.
Arq Bras Oftalmol ; 68(1): 49-53, 2005.
Artigo em Português | MEDLINE | ID: mdl-15824803

RESUMO

PURPOSE: To study the prevalence of glaucoma in employees of a public hospital in São Paulo and to analyze the role of frequency doubling perimetry along with non-contact tonometry and direct ophthalmoscopy, in the screening for glaucoma. METHODS: 612 employees of the Central Hospital of the "Santa Casa de São Paulo" were evaluated from October 15 to 20, 2000; 438 were women and 174 men, with mean age of 45.05+/-7.7 years (range, 35 to 81 years); 437 were white, 104 mulatto, 43 black and 28 Asian. All examinations were done by 10 eye specialists with experience in glaucoma. All employees had both eyes examined, by means of frequency doubling perimetry (FDT), ophthalmoscopy (FO), and non-contact tonometry (TNC). RESULTS: 159 (25.98%) subjects presented with at least one abnormal testing; 5 (3.14%) had high IOP (TNC+); 13 (8.17%) presented suspicious disk (FO+); 110 (69.18%) presented abnormal FDT (FDP+); 8 (5.03%) TNC+ and FO+; 10 (6.28%) had TNC+ and FDT+; 9 (5.66%) presented FO+ and FDT+; 4 (2.51%) had TNC+, FO+ and FDT+; 12 (1.96%) individuals were diagnosed with glaucoma, four of whom (0.65%), with normal pressure glaucoma. CONCLUSIONS: Frequency doubling perimetry was found to be an important step in the screening for glaucoma in the study. Of the 12 individuals that had the diagnosis of glaucoma, 5 (41.6%) would not have been diagnosed if they had not undergone frequency doubling perimetry.


Assuntos
Glaucoma/diagnóstico , Programas de Rastreamento/métodos , Recursos Humanos em Hospital , Testes de Campo Visual/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Brasil/epidemiologia , Feminino , Glaucoma/epidemiologia , Hospitais Públicos , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Prevalência , Sensibilidade e Especificidade , Tonometria Ocular , População Urbana
4.
Arq. bras. oftalmol ; 68(1): 49-53, jan.-fev. 2005. ilus
Artigo em Português | LILACS | ID: lil-396355

RESUMO

OBJETIVO: Estudar a prevalência de glaucoma, em funcionários da Santa Casa de Misericórdia de São Paulo e analisar a validade da inclusão da perimetria de freqüência dupla junto à tonometria de não-contato e à oftalmoscopia direta, na triagem para glaucoma. MÉTODOS: Foram examinados 612 funcionários voluntários, 438 mulheres e 174 homens, com idade média de 45,05±7,7 anos. Eram 437 da raça branca, 104 mulatos, 43 da raça negra e 28 da raça amarela. Todos os funcionários tiveram ambos os olhos examinados por especialistas em glaucoma, que realizaram os seguintes exames: perimetria de freqüência dupla (FDT), oftalmoscopia direta (FO), tonometria de não-contato (TNC). RESULTADOS: Dos 612 indivíduos triados, 159 (25,98 por cento) apresentaram alguma anormalidade em pelo menos um dos exames: 5 (3,14 por cento) apresentaram pressão intra-ocular elevada (TNC+); 13 (8,17 por cento) apresentaram oftalmoscopia suspeita (FO+); 110 (69,18 por cento) apresentaram perimetria de freqüência dupla alterado (FDT+); 8 (5,03 por cento) TNC+ e FO+; 10 (6,28 por cento) TNC+ e FDT+; 9 (5,66 por cento) FO+ e FDT+; 4 (2,51 por cento) TNC+, FO+ e FDT+. Foram detectados 12 (1,96 por cento) indivíduos com glaucoma, quatro dos quais (0,65 por cento) com glaucoma de pressão normal. CONCLUSÕES: A perimetria de freqüência dupla mostrou-se útil para o rastreamento de glaucoma dentro da amostragem estudada. Do total de 12 indivíduos que tiveram o diagnóstico de glaucoma, 5 (41,6 por cento) não teriam sido detectados se não tivessem sido submetidos a perimetria de freqüência dupla.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Hospitais Públicos , Oftalmoscopia/métodos , Tonometria Ocular/métodos , Testes de Campo Visual , Brasil
5.
Arq. bras. oftalmol ; 67(4): 581-583, jul.-ago. 2004. tab
Artigo em Português | LILACS | ID: lil-386047

RESUMO

OBJETIVO: Verificar a existência de diferença estatisticamente significativa entre exames de campimetria computadorizada, realizados com a utilização da correção total e do equivalente esférico, em pacientes com ametropia cilíndrica de valores iguais ou maiores que 1,50 dioptrias. MÉTODOS: Vinte pacientes (35 olhos) foram submetidos a exame de campo visual, perimetria computadorizada Humphrey - estratégia SITA 24-2, usando em um exame a correção total e em outro o equivalente esférico. Foram utilizados como parâmetros de comparação os valores de Mean Deviation, Pattern Standard Deviation, perdas de fixação, falso-positivos, falso-negativos e duração dos exames. RESULTADOS: Os parâmetros Mean Deviation, Standard Pattern Deviation, falso-positivos, falso-negativos e duração do exame não apresentaram diferença estatisticamente significativa. A perda de fixação foi maior no grupo usando correção cilíndrica total, dado estatisticamente significante. CONCLUSAO: Exames de campo visual realizados com equivalente esférico não mostram diferença na sensibilidade retínica quando comparados com o uso de correção cilíndrica total, dentro dos padrões adotados neste estudo.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Erros de Refração/diagnóstico , Limiar Sensorial , Testes de Campo Visual , Percepção Visual , Campos Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...