1.
Semin Thorac Cardiovasc Surg ; 31(4): 643-649, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31229691

RESUMO

Aortic valve surgery in non-elderly patients represents a very challenging patient population. The younger the patient is at the point of aortic valve intervention, the longer their anticipated life expectancy will be, with longer exposure to valve-related complications and risk for re-operation. Although the latest international guidelines recommend aortic valve repair in patients with aortic valve insufficiency, what we see in the real world is that the vast majority of these aortic valves are replaced. However, current prosthetic valves has now been shown to lead to significant loss of life expectancy for non-elderly patients up to 50% for patients in their 40s undergoing mechanical aortic valve replacement. Bioprostheses carry an even worse long-term survival, with higher rates of re-intervention. The promise of trans-catheter valve-in-valve technology is accentuating the trend of bioprosthetic implantation in younger patients, without yet the appropriate evidence. In contrast, aortic valve repair has shown excellent outcomes in terms of quality of life, freedom from re-operation and freedom from major adverse valve-related events with similar life expectancy to general population as it is also found for the Ross procedure, the only available living valve substitute. We are at a time when the paradigm of aortic valve surgery needs to change for the better. To better serve our patients, we must acquire high quality real-world evidence from multiple centers globally - this is the vision of the AVIATOR registry and our common responsibility.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Adulto , Fatores Etários , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Bioprótese , Medicina Baseada em Evidências , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Expectativa de Vida , Pessoa de Meia-Idade , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
J Thorac Cardiovasc Surg ; 157(6): 2202-2211.e7, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30553597

RESUMO

OBJECTIVES: Current national registries are lacking detailed pathology-driven analysis and long-term patients outcomes. The Heart Valve Society (HVS) aortic valve (AV) repair research network started the Aortic Valve Insufficiency and ascending aorta Aneurysm InternATiOnal Registry (AVIATOR) to evaluate long-term patient outcomes of AV repair and replacement. The purpose of the current report is to describe the AVIATOR initiative and report in a descriptive manner the patients included. METHODS: The AV repair research network includes surgeons, cardiologists, and scientists and established an online database compliant with the guidelines for reporting valve-related events. Prospective inclusion started from January 2013. Adult patients (18 years or older) who were operated on between 1995 and 2017 with complete procedural specification of the type of repair/replacement were selected for descriptive analysis. RESULTS: Currently 58 centers from 17 countries include 4896 patients with 89% AV repair (n = 4379) versus 11% AV replacement (n = 517). AV repair was either isolated (28%), or associated with tubular/partial root replacement (22%) or valve-sparing root replacement (49%) with an in-hospital mortality of 0.5%, 1.7%, and 1.2%, respectively. AV replacement was either isolated (24%), associated with tubular/partial root replacement (17%) or root replacement (59%) with an in-hospital mortality of 1%, 2.6%, and 2.0%, respectively. CONCLUSIONS: The multicenter surgical AVIATOR registry, by applying uniform definitions, should provide a solid evidence base to evaluate the place of repair versus replacement on the basis of long-term patient outcomes. Obtaining data completeness and adequate representation of all surgery types remain challenging. Toward the near future AVIATOR-medical will start to study natural history, as will AVIATOR-kids, with a focus on pediatric disease.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Adolescente , Adulto , Idoso , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aneurisma Aórtico/complicações , Insuficiência da Valva Aórtica/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Adulto Jovem
4.
J Heart Valve Dis ; 22(1): 79-84, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23610993

RESUMO

BACKGROUND AND AIM OF THE STUDY: The study aim was to define the timing of cerebral embolization events during transcatheter aortic valve implantation (TAVI), and to determine if events were more closely associated with valve implantation or with balloon inflation. METHODS: Between January 2008 and November 2011, a total of 114 patients underwent TAVI at the author's institution. Of these patients, 44 had previously undergone imaging before and after TAVI, and were included in the study (26 transfemoral (TF); 18 transapical (TA)). Eleven patients who had only balloon valvuloplasty (BV) during the same period were included, as were 22 patients who had open aortic valve replacement (AVR), as controls. All 77 patients underwent neurological examination, and all had cerebral MRIs before and after their procedures. RESULTS: Fifty of the 77 patients who underwent postprocedural MRI had new cerebral lesions, as follows: 24/26 (92%) in TF patients; 17/18 (94%) in TA patients; 3/11 (27%) in BV patients; and 6/22 (27%) in AVR patients (TF and TA versus BV and AVR, p < 0.0001). The mean number and volume of embolic lesions per patient were respectively 5.4/438 mm3 for TF, 11.6/3414 mm3 for TA, 0.7/46 mm3 for BV, and 0.4/48 mm3 for AVR (TF versus TA and BV versus AVR, p = NS; TF and TA versus BV and AVR, p < 0.0001). No association was found between either the EuroSCORE or patient age and the number of events. CONCLUSION: In the present study, an incidence of silent cerebral embolic lesions after TAVI was identified which was significantly higher than that for BV or AVR. This indicated an association of embolism with valve implantation rather than with balloon inflation.


Assuntos
Valvuloplastia com Balão/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Embolia Intracraniana/etiologia , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Masculino , Estudos Prospectivos
6.
J Thorac Cardiovasc Surg ; 143(4 Suppl): S91-5, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22306214

RESUMO

OBJECTIVE: During the last 2 decades, we have applied a repair-oriented surgical approach to patients with active mitral valve endocarditis. We retrospectively analyzed the long-term outcomes with this repair-oriented approach. METHOD: Between 1991 and 2010, 137 patients underwent operation for active mitral valve endocarditis; of these, 109 patients (80%) had mitral valve repair and represent the study cohort. Repair techniques without patch extension (no-patch techniques) include triangular or quadrangular resection (n = 49), sliding plasty (n = 24), neochordae (n = 18), chordal transfer (n = 12), and others (n = 5). Repair techniques using patch extension (patch techniques) included pericardium (n = 42), tricuspid autograft (n = 8), flip-over technique (n = 7), and partial mitral valve homograft (n = 5). Patches were used in 67 patients (61%). Ring annuloplasty was performed in 60 patients, and a pericardial band was used in 13 patients. Clinical and echocardiographic follow-up were performed. Median follow-up was 48 months. RESULTS: Hospital mortality was 16%. At 8 years, overall survival was 62% ± 10% with no differences between patients with or without patch repair (P = .5). Freedom from mitral valve repair failure was 81% ± 14% in patients with patch repair and 90% ± 10% in patients without patch repair (P = .09). The rate of thromboembolic or bleeding event was 1% per patient-year, and the rate of endocarditis recurrence was 0.3% per patient-year. Univariable predictors of mortality were age more than 70 years (P < .0001), perivalvular abscess (P = .002), diabetes mellitus (P = .0002), and renal failure (P = .04). Predictors of repair failure were renal failure (P = .035) and perivalvular abscess (P = .033). CONCLUSIONS: In active mitral valve endocarditis, a repair-oriented surgical approach achieves a reparability rate of 80% with acceptable morbidity and good long-term results. The use of patch techniques offers a durability rate that approximates the rate obtained with the no-patch techniques.


Assuntos
Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica , Endocardite/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/mortalidade , Recidiva , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Interact Cardiovasc Thorac Surg ; 14(4): 378-80, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22235001

RESUMO

We developed a novel resection device to use during transapical transcatheter aortic valve implantation (TAVI) using a circular blade. We assessed the device in 15 human cadavers by transapical approach. After the resection, the aortic annulus was measured using standard probes. A careful examination of the aortic wall, left ventricular outflow tract, coronary ostia and mitral valve was performed using an endpoint checklist, developed specifically for the new device. The resection was successfully completed in 14 out of 15 (93%) cases. All the resected leaflets and debris have been successfully evaluated in 15 out of 15 (100%) cases. One case of a bicuspid valve had a prominent calcification of the median raphe. The resection tool could only perform a partial resection. The mean duration of the resection was 45 ± 30 s. The surrounding tissue examination did not reveal any injury to the anatomical structures. Endovascular resection of the native valve using transapical approach is feasible and effective. Further developments are necessary before the definitive clinical use during percutaneous aortic valve implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Instrumentos Cirúrgicos , Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Cadáver , Lista de Checagem , Desenho de Equipamento , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Teste de Materiais , Fatores de Tempo
9.
Interact Cardiovasc Thorac Surg ; 6(1): 56-9, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17669769

RESUMO

We described our mid-term results in repairing prolapsing aortic cusps in 21 patients with aortic regurgitation and normal aortic root morphology. Aortic regurgitation was moderate-severe in five patients and severe in 16 patients. Prolapse involved the left cusp in four patients (19%), the right cusp in 10 patients (47%) and the non-coronary cusp in 7 (33%) patients. Correction of the prolapsing cusp was achieved by either free edge plication, triangular resection or resuspension with polytetrafluoroethylene sutures, frequently associated to a subcommissural annuloplasty. There was no hospital death. At discharge transthoracic echocardiography, 18 patients (85%) showed no residual aortic regurgitation and three patients (14%) had trivial aortic regurgitation with a central jet. Mean clinical follow-up was 27.2+/-17.1 months (range: 10-72 months). Overall survival was 90.5%. At follow-up transthoracic echocardiography, fourteen patients (73%) were free from aortic regurgitation and five patients (26%) had mild aortic regurgitation without clinical signs of congestive heart failure. Correction of valve prolapse appears a reasonable extension of the original techniques of valve-preserving surgery.


Assuntos
Prolapso da Valva Aórtica/cirurgia , Adulto , Idoso , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Prolapso da Valva Aórtica/complicações , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Reoperação , Taxa de Sobrevida , Técnicas de Sutura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...