Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 43(4): 568-574, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35301225

RESUMO

BACKGROUND: The efficacy of combined aspiration catheter and stent retriever compared with stent retriever alone for the treatment of large-vessel occlusion acute ischemic stroke is unclear. PURPOSE: Our aim was to conduct a systematic literature review and meta-analysis on several metrics of efficacy comparing aspiration catheter and stent retriever with stent retriever alone. DATA SOURCES: MEDLINE and the Cochrane Library Databases were searched. Randomized controlled trials and case-control and cohort studies were included. STUDY SELECTION: Ten comparative studies were included detailing a combined 1495 patients with aspiration catheter and stent retriever and 1864 with stent retrievers alone. DATA ANALYSIS: Data on first pass effect (TICI 2b/2c/3 after first pass), final successful reperfusion (modified TICI ≥2b), and 90-day functional independence (mRS ≤ 2) were collected. Meta-analysis was performed using a random-effects model. DATA SYNTHESIS: There was a pooled composite first pass effect of 40.8% (611/1495) versus 32.6% (608/1864) for aspiration catheter and stent retriever and stent retriever alone, respectively (P < .0001). Similarly, on a meta-analysis, aspiration catheter and stent retriever were associated with a higher first pass effect compared with stent retriever alone (OR = 1.63; 95% CI, 1.20-2.21; P = .002; I2 = 72%). There was no significant difference in composite rates of successful reperfusion between aspiration catheter and stent retriever (72.8%, 867/1190) and stent retriever alone (70.8%, 931/1314) (P = .27) or on meta-analysis (OR = 1.31; CI, 0.81-2.12; P = .27; I2 = 82%). No difference was found between aspiration catheter and stent retriever and stent retriever alone on 90-day functional independence (OR = 1.02; 95% CI, 0.77-1.36; P = .88; I2 = 40%). LIMITATIONS: This study is limited by high interstudy heterogeneity. CONCLUSIONS: On meta-analysis, aspiration catheter and stent retriever are associated with a superior first pass effect compared with stent retriever alone, but they are not associated with statistically different final reperfusion or functional independence.


Assuntos
Arteriopatias Oclusivas , Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Arteriopatias Oclusivas/complicações , Isquemia Encefálica/complicações , Isquemia Encefálica/cirurgia , Catéteres , Humanos , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/complicações , Trombectomia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...