Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 15670, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38977735

RESUMO

Degenerative mitral valve disease is a common valvular disease with two arguably distinct phenotypes: fibroelastic deficiency and Barlow's disease. These phenotypes significantly alter the microstructures of the leaflets, particularly the collagen fibers, which are the main mechanical load carriers. The predominant method of investigation is histological sections. However, the sections are cut transmurally and provide a lateral view of the microstructure of the leaflet, while the mechanics and function are determined by the planar arrangement of the collagen fibers. This study, for the first time, quantitatively examined planar collagen distribution quantitatively in health and disease using second harmonic generation microscopy throughout the thickness of the mitral valve leaflets. Twenty diseased samples from eighteen patients and six control samples were included in this study. Healthy tissue had highly aligned collagen fibers. In fibroelastic deficiency they are less aligned and in Barlow's disease they are completely dispersed. In both diseases, collagen fibers have two preferred orientations, which, in contrast to the almost constant one orientation in healthy tissues, also vary across the thickness. The results indicate altered in vivo mechanical stresses and strains on the mitral valve leaflets as a result of disease-related collagen remodeling, which in turn triggers further remodeling.


Assuntos
Colágeno , Valva Mitral , Humanos , Valva Mitral/metabolismo , Valva Mitral/patologia , Colágeno/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Idoso , Prolapso da Valva Mitral/metabolismo , Prolapso da Valva Mitral/patologia , Adulto
2.
Acta Biomater ; 164: 269-281, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37003496

RESUMO

Degenerative mitral valve disease is the main cause of primary mitral regurgitation with two phenotypes: fibroelastic deficiency (FED) often with localized myxomatous degeneration and diffuse myxomatous degeneration or Barlow's disease. Myxomatous degeneration disrupts the microstructure of the mitral valve leaflets, particularly the collagen fibers, which affects the mechanical behavior of the leaflets. The present study uses biaxial mechanical tests and second harmonic generation microscopy to examine the mechanical behavior of Barlow and FED tissue. Three tissue samples were harvested from a FED patient and one sample is from a Barlow patient. Then we use an appropriate constitutive model by excluding the collagen fibers under compression. Finally, we built an FE model based on the echocardiography of patients diagnosed with FED and Barlow and the characterized material model and collagen fiber orientation. The Barlow sample and the FED sample from the most affected segment showed different mechanical behavior and collagen structure compared to the other two FED samples. The FE model showed very good agreement with echocardiography with 2.02±1.8 mm and 1.05±0.79 mm point-to-mesh distance errors for Barlow and FED patients, respectively. It has also been shown that the exclusion of collagen fibers under compression provides versatility for the material model; it behaves stiff in the belly region, preventing excessive bulging, while it behaves very softly in the commissures to facilitate folding. STATEMENT OF SIGNIFICANCE: This study quantifies for the first time the collagen microstructure and mechanical behavior of degenerative mitral valve (DMV) leaflets. These data will then be used for the first disease-specific finite element (FE) model of DMV. While current surgical repair of DMV is based on surgical experience, FE modeling has the potential to support decision-making and make outcomes predictable. We adopt a constitutive model to exclude collagen fiber under compressions, an important consideration when modeling the mitral valve, where the leaflets are folded to ensure complete closure. The results of this study provide essential data for understanding the relationship between collagen microstructure and degenerative mitral valve mechanics.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/cirurgia , Análise de Elementos Finitos , Colágeno
4.
Ann Thorac Surg ; 96(6): 2123-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24070701

RESUMO

BACKGROUND: Acute dysfunction of mechanical aortic valve prostheses is a life-threatening adverse event. Pannus overgrowth, which is fibroelastic hyperplasia originating from the periannular area, is one cause of dysfunction. The aim of this study was to determine the annual incidence of readmittance resulting from acute obstruction caused by pannus during 30 years of observation in patients with Medtronic-Hall aortic valve prostheses and to analyze the risk factors associated with pannus development. METHODS: From 1982 to 2004, 1,187 patients in our department underwent aortic valve replacement with Medtronic-Hall mechanical monoleaflet valve prostheses. As of December 31, 2012, 27 of these patients (2.3%) had presented with acute valve dysfunction caused by pannus obstruction. RESULTS: The annual incidence of pannus was 0.7 per 1,000. The median time from the primary operation to prosthetic dysfunction was 11.1 years (range, 1.2 to 26.8 years). Of the 20 patients who underwent reoperation, 2 died. Seven patients died before reoperation. Women had a higher risk for the development of obstructing pannus, and patients with pannus obstruction were younger. Valve size was not an independent risk factor. CONCLUSIONS: Women and younger patients are at higher risk for pannus development. When acute dysfunction by pannus is suspected in a mechanical aortic valve, an immediate echocardiogram and an emergency aortic valve replacement should be carried out because of the potential of a fatal outcome.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Doença Aguda , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Ecocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Noruega/epidemiologia , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...