Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Mol Genet Metab ; 115(1): 17-22, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25862610

RESUMO

BACKGROUND: There appears little consensus concerning protein requirements in phenylketonuria (PKU). METHODS: A questionnaire completed by 63 European and Turkish IMD centres from 18 countries collected data on prescribed total protein intake (natural/intact protein and phenylalanine-free protein substitute [PS]) by age, administration frequency and method, monitoring, and type of protein substitute. Data were analysed by European region using descriptive statistics. RESULTS: The amount of total protein (from PS and natural/intact protein) varied according to the European region. Higher median amounts of total protein were prescribed in infants and children in Northern Europe (n=24 centres) (infants <1 year, >2-3g/kg/day; 1-3 years of age, >2-3 g/kg/day; 4-10 years of age, >1.5-2.5 g/kg/day) and Southern Europe (n=10 centres) (infants <1 year, 2.5 g/kg/day, 1-3 years of age, 2 g/kg/day; 4-10 years of age, 1.5-2 g/kg/day), than by Eastern Europe (n=4 centres) (infants <1 year, 2.5 g/kg/day, 1-3 years of age, >2-2.5 g/kg/day; 4-10 years of age, >1.5-2 g/kg/day) and with Western Europe (n=25 centres) giving the least (infants <1 year, >2-2.5 g/kg/day, 1-3 years of age, 1.5-2 g/kg/day; 4-10 years of age, 1-1.5 g/kg/day). Total protein prescription was similar in patients aged >10 years (1-1.5 g/kg/day) and maternal patients (1-1.5 g/kg/day). CONCLUSIONS: The amounts of total protein prescribed varied between European countries and appeared to be influenced by geographical region. In PKU, all gave higher than the recommended 2007 WHO/FAO/UNU safe levels of protein intake for the general population.


Assuntos
Aminoácidos/administração & dosagem , Caseínas/administração & dosagem , Proteínas Alimentares/administração & dosagem , Suplementos Nutricionais , Fragmentos de Peptídeos/administração & dosagem , Fenilcetonúrias/dietoterapia , Adulto , Criança , Pré-Escolar , Europa (Continente) , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Fenilalanina , Inquéritos e Questionários , Turquia , Organização Mundial da Saúde
3.
Ophthalmol Clin North Am ; 14(2): 359-76, ix, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11406431

RESUMO

Excimer laser photorefractive keratectomy has become an increasingly popular surgical treatment for the correction of myopia. Unfortunately, no surgical technique can be entirely without complications. This article discusses the problems encountered following PRK for myopia in two main sections: those primarily refractive or optical in nature and those causing medical problems.


Assuntos
Córnea/cirurgia , Miopia/cirurgia , Ceratectomia Fotorrefrativa/efeitos adversos , Complicações Pós-Operatórias , Topografia da Córnea , Infecções Oculares/etiologia , Ofuscação , Humanos , Lasers de Excimer , Ativação Viral , Acuidade Visual , Cicatrização
5.
J Cataract Refract Surg ; 22(7): 951-4, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9041088

RESUMO

PURPOSE: To assess the results of implantation of secondary, open-loop, flexible, anterior chamber intraocular lenses (IOLs) and compare the findings with those of other published studies. SETTING: A combined ophthalmology and ear, nose, and throat hospital in Middlesbrough, Cleveland, England. METHODS: This retrospective study comprised 81 patients who had secondary implantation of a flexible, open-loop, anterior chamber IOL by the one surgeon. The incidence of postoperative complications was ascertained, and best corrected preoperative and postoperative visual acuities were compared. RESULTS: Two serious complications occurred: one severe loss of vision that is still under investigation and one retinal detachment that was repaired with good residual visual function. Of all 81 patients, 92.5% were within one Snellen line of their preoperative best corrected visual acuity. These results compare favorably with those of other published studies. CONCLUSION: Using an open-loop, flexible, anterior chamber lens for secondary implantation is still an acceptable way to treat aphakia. The poor reputation of these lenses is undeserved.


Assuntos
Câmara Anterior/cirurgia , Afacia Pós-Catarata/cirurgia , Lentes Intraoculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Humanos , Incidência , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Acuidade Visual
6.
J Cataract Refract Surg ; 22(2): 243-6, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8656392

RESUMO

OBJECTIVES: To analyze 50 cases of flexible open-loop anterior chamber intraocular lens (IOL) implantation after posterior capsule rupture and vitreous loss and compare the results with those of other published series. SETTING: North Riding Infirmary, Cleveland, England. METHODS: This retrospective study, with a follow-up between 3 and 81 months, comprised all patients who had a flexible open-loop anterior chamber IOL implanted because of significant posterior capsule problems during extracapsular cataract extraction. The incidence of postoperative complications and best corrected visual acuity results were determined. RESULTS: Three patients with cystoid macular edema achieved final best corrected visual acuity of 6/9 (20/30). There was one retinal detachment and one traumatic incision rupture with IOL loss 6 weeks postoperatively and subsequent retinal detachment and phthisis. Seventy-two percent achieved a best corrected visual acuity of 6/9 (20/30). CONCLUSIONS: Our results agree with those of other published series. Implantation of a flexible open-loop anterior chamber IOL as a primary lens is still an acceptable way of treating posterior capsule complications in cataract surgery.


Assuntos
Câmara Anterior/cirurgia , Extração de Catarata/efeitos adversos , Cápsula do Cristalino/lesões , Lentes Intraoculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Ruptura/etiologia , Ruptura/cirurgia , Acuidade Visual
8.
Eye (Lond) ; 8 ( Pt 3): 343-5, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7958044

RESUMO

A short pilot study is described which investigates some of the mechanical properties of ophthalmic sutures. The Alcon 10/0 monofilament nylon suture was found to behave in a mechanically consistent manner. Like all nylon it possesses the property of 'creep', which helps to compensate for overtightening of the section during surgery.


Assuntos
Teste de Materiais/métodos , Suturas , Astigmatismo/prevenção & controle , Córnea/cirurgia , Humanos , Nylons , Projetos Piloto , Complicações Pós-Operatórias/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...