Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 23(9): 1-14, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30232845

RESUMO

To approach wide-field optical properties quantification in real heterogeneous biological tissue, we developed a Dual-Step setup that couples a punctual diffuse reflectance spectroscopy (DRS) technique with multispectral imaging (MSI). The setup achieves wide-field optical properties assessment through an initial estimation of scattering with DRS, which is used to estimate absorption with MSI. The absolute quantification of optical properties is based on the ACA-Pro algorithm that has been adapted both for DRS and for MSI. This paper validates the Dual-Step system not only on homogeneous Intralipid phantoms but also on a heterogeneous gelatine phantom with different scattering and absorbing properties.


Assuntos
Imagem Óptica , Análise Espectral , Algoritmos , Calibragem , Desenho de Equipamento , Modelos Biológicos , Imagem Óptica/instrumentação , Imagem Óptica/métodos , Imagem Óptica/normas , Imagens de Fantasmas , Reprodutibilidade dos Testes , Análise Espectral/instrumentação , Análise Espectral/métodos , Análise Espectral/normas
2.
J Biomed Opt ; 21(6): 65003, 2016 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-27281063

RESUMO

We have developed an adaptive calibration algorithm and protocol (ACA-Pro) that corrects from the instrumental response of various spatially resolved diffuse reflectance spectroscopy (DRSsr) systems to enable the quantification of absorption and scattering properties based on a Monte Carlo-based look-up-table approach. The protocol involves the use of a calibration reference base built with measurements of a range of different diffusive intralipid phantoms. Moreover, an advanced strategy was established to take into account the experimental variations with an additional measurement of a common solid material, allowing the use of a single calibration reference base for all experiments. The ACA-Pro is validated in contact and noncontact probe-based DRSsr systems. Furthermore, the first results of a setup replacing the probe with a CCD detector are shown to confirm the robustness of the approach.


Assuntos
Algoritmos , Análise Espectral/métodos , Calibragem , Difusão , Corantes Fluorescentes , Método de Monte Carlo , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...