Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Cardiovasc Intervent Radiol ; 40(6): 864-872, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28144756

RESUMO

PURPOSE: Percutaneous isolated hepatic perfusion (PIHP) with Melphalan has been developed as a treatment for patients with isolated hepatic metastases of uveal melanoma. We discuss patient outcome and safety in a retrospective multi-centre study. MATERIALS AND METHODS: Between 2012 and 2016 18 patients with un-resectable isolated hepatic metastases of uveal melanoma received single or repeated PIHP with Melphalan (n = 35) at seven sites. Progression-free time, overall survival time (OS) and tumour response by means of RECIST 1.1 criteria were evaluated. Peri- and post-procedural adverse events (AE) were registered. Patients' life quality was assessed using four-point scale questionnaires. RESULTS: Of 18 patients, initial PIHP treatment resulted in partial response (PR) in eight, stable disease (SD) in seven and progressive disease (PD) in three cases. Nine patients underwent second PIHP with PR in eight cases and PD in one case. Six patients were evaluated after third PIHP with PR in five patients and SD in one patient. Two patients received fourth PIHP with PD in both cases. Median OS was 9.6 months (range 1.6-41.0 months). Median progression-free survival time was 12.4 months (range 0.9-41.0 months) with 1-year survival of 44%. Most common post-procedural AE grade 3 and 4 were temporary leukopenia (n = 11) and thrombocytopenia (n = 8). Patients' self-assessments showed good ratings for overall health and quality of life with only slight changes after PIHP, and a high degree of satisfaction with PIHP treatment. CONCLUSION: PIHP with Melphalan proved to be a relatively safe, minimal-invasive and repeatable treatment for patients with non-resectable hepatic metastases of uveal melanoma.


Assuntos
Quimioterapia do Câncer por Perfusão Regional/métodos , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/secundário , Melanoma/tratamento farmacológico , Melfalan/uso terapêutico , Neoplasias Uveais/tratamento farmacológico , Adulto , Idoso , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/mortalidade , Masculino , Melanoma/mortalidade , Pessoa de Meia-Idade , Qualidade de Vida , Estudos Retrospectivos , Taxa de Sobrevida , Neoplasias Uveais/mortalidade
2.
Case Rep Oncol ; 9(1): 158-63, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27065847

RESUMO

We report on a 90-year-old male patient with a ROS1-translocated adenocarcinoma of the lung who was treated with crizotinib as first-line therapy. After 11 months of treatment, we noticed complete metabolic response as measured by (18)F-FDG-PET/CT scan and a partial response according to RECIST criteria. This patient indicates that ROS1 translocations are not restricted to young age, female gender and low stage. Furthermore, this case illustrates exemplarily that crizotinib therapy is effective and manageable even as first-line treatment in elderly patients with comorbidities. Based on our findings, we recommend to include elderly patients with advanced pulmonary adenocarcinomas in molecular screening approaches for ROS1 translocations.

3.
BMC Clin Pathol ; 13: 4, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23379654

RESUMO

BACKGROUND: The autosomal dominant tumor syndrome tuberous sclerosis complex is caused by the mutated TSC1 gene, hamartin, and the TSC2 gene, tuberin. Patients with this complex develop typical cutaneus symptoms such as peau chagrin or angiofibromas of the skin as well as other lesions such as astrocytomas in the brain and lymphangioleiomyomatosis in the lung. Only a few tuberous sclerosis patients have been described who showed a multifocal micronodular pneumocyte hyperplasia of the lung. Another benign tumor which often occurs together with tuberous sclerosis is the angiomyolipoma of the kidney. Furthermore, an increased incidence of renal cell carcinoma in connection with tuberous sclerosis has also been proven. CASE PRESENTATION: We report a 13-year-old white girl with epilepsy and hypopigmented skin lesions. Radiological studies demonstrated the typical cortical tubers leading to the diagnosis of tuberous sclerosis. In the following examinations a large number of angiomyolipomas were found in both kidneys. One lesion showed an increasing size and tumor like aspects in magnetic resonance imaging. The pathological examination of the following tumorectomy demonstrated an unclassified renal cell carcinoma. Four months postoperatively, a follow-up computer tomography revealed multiple bilateral pulmonary nodules. To exclude lung metastases of the renal cell carcinoma, multiple open-lung biopsies were performed. CONCLUSION: Here we report a diagnostically challenging case of a 13-year-old patient with tuberous sclerosis and angiomyolipomas of the kidney who developed an unclassified renal cell carcinoma as well as multifocal micronodular pneumocyte hyperplasia.

4.
Eur Radiol ; 18(2): 298-307, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17901958

RESUMO

The value of a computer-aided detection tool (CAD) as second reader in combination with experienced and inexperienced radiologists for the diagnosis of acute pulmonary embolism (PE) was assessed prospectively. Computed tomographic angiography (CTA) scans (64 x 0.6 mm collimation; 61.4 mm/rot table feed) of 56 patients (31 women, 34-89 years, mean = 66 years) with suspected PE were analysed by two experienced (R1, R2) and two inexperienced (R3, R4) radiologists for the presence and distribution of emboli using a five-point confidence rating, and by CAD. Informed consent was obtained from all patients. Results were compared with an independent reference standard. Inter-observer agreement was calculated by kappa, confidence assessed by ROC analysis. A total of 1,116 emboli [within mediastinal (n = 72), lobar (n = 133), segmental (n = 465) and subsegmental arteries (n = 455)] were included. CAD detected 343 emboli (sensitivity = 30.74%, correct-positive rate = 6.13/patient; false-positive rate = 4.1/patient). Inter-observer agreement was good (R1, R2: kappa = 0.84, 95% CI = 0.81-0.87; R3, R4: kappa = 0.79, 95% CI = 0.76-0.81). Extended inter-observer agreement was higher in mediastinal and lobar than in segmental and subsegmental arteries (kappa = 0.84-0.86 and kappa = 0.51-0.58 for mediastinal/lobar and segmental/subsegmental arteries, respectively P < 0.05). Agreement between experienced and inexperienced readers was improved by CAD (kappa = 0.60-0.62 and kappa = 0.69-0.72 before and after CAD consensus, respectively P < 0.05). The experienced outperformed the inexperienced readers (Az = 0.95, 0.93, 0.89 and 0.86 for R1-4, respectively, P < 0.05). CAD significantly improved overall performances of readers 3 and 4 (Az = 0.86 for R3, R4 and Az = 0.89 for R3, R4 with CAD, P < 0.05), by enhancing sensitivities in segmental/subsegmental arteries. CAD improved experienced readers' sensitivities in segmental/subsegmental arteries (sens. = 0.93 and 0.90 for R1, R2 before and 0.97 and 0.94 for R1, R2 after CAD consensus, P < 0.05), without significant improvement of their overall performances (P > 0.05). Particularly inexperienced readers benefit from consensus with CAD data, greatly improving detection of segmental and subsegmental emboli. This system is advocated as a second reader.


Assuntos
Competência Clínica/estatística & dados numéricos , Diagnóstico por Computador/métodos , Embolia Pulmonar/diagnóstico , Radiologia/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Diagnóstico por Computador/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Curva ROC , Radiologia/estatística & dados numéricos , Valores de Referência , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
5.
Eur Radiol ; 17(10): 2561-71, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17492290

RESUMO

The purpose of this study was to evaluate the reproducibility of CT-volumetric tumour response assessment of pulmonary metastasis using variable volume change thresholds (VCT) and target lesions with response evaluation criteria in solid tumours (RECIST). Fifty consecutive patients with pulmonary metastases undergoing follow-up multislice CT under chemotherapy were assessed for response to chemotherapy with modifications to RECIST: (1) decreasing the percentual VCT for diagnosis of tumour response (range = 70%-20%), (2) reducing the number of target lesions (range = 1-5). Continuous and categorical observer agreements were tested by Bland and Altman and extended (kappa(e)) or non-weighted kappa (kappa) and correlated with percentual VCT to predict observer agreement. A total of 202 metastases were evaluated (average volume = 522.4 mm(3) +/- 902.4 mm(3)). General agreement on treatment response was very high (kappa(e) = 0.93-1), but was reduced with VCT < 35% (kappa(e) < 0.95). Kappa correlation with VCT values was strong (r=0.94-0.96; p< or =0.0002). Average confidence decreased significantly at VCT < 45% (p < 0.01) and agreement on stable disease at VCT < 35% (kappa(e) < 0.95; p < 0.01). Reduction of target lesions (n < 3; VCT = 35%) resulted in decreased reader confidence (for n = 1: kappa = 0.49; p < 0.05). Agreement for evaluation of treatment response was robust using VCT > or =35% and > or =3 metastases. This may translate into shortening of follow-up intervals or enable for response assessment with tumours displaying minimal volume change.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Estudos Longitudinais , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
6.
Eur Radiol ; 17(4): 888-901, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17047961

RESUMO

With use of multislice computed tomography (MSCT), small pulmonary nodules are being detected in vast numbers, constituting the majority of all noncalcified lung nodules. Although the prevalence of lung cancers among such lesions in lung cancer screening populations is low, their isolation may contribute to increased patient survival. Computer-aided diagnosis (CAD) has emerged as a diverse set of diagnostic tools to handle the large number of images in MSCT datasets and most importantly, includes automated detection and volumetry of pulmonary nodules. Current CAD systems can significantly enhance experienced radiologists' performance and outweigh human limitations in identifying small lesions and manually measuring their diameters, augment observer consistency in the interpretation of such examinations and may thus help to detect significantly higher rates of early malignomas and give more precise estimates on chemotherapy response than can radiologists alone. In this review, we give an overview of current CAD in lung nodule detection and volumetry and discuss their relative merits and limitations.


Assuntos
Diagnóstico por Computador , Neoplasias Pulmonares/diagnóstico , Metástase Neoplásica/diagnóstico , Nódulo Pulmonar Solitário/diagnóstico , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
7.
AJR Am J Roentgenol ; 186(5): 1265-71, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16632717

RESUMO

OBJECTIVE: To predict cor pulmonale and short-term outcome in patients with pulmonary embolism (PE), we retrospectively investigated three morphology-based MDCT systems for scoring pulmonary artery obstruction. MATERIALS AND METHODS: Eighty-nine consecutive patients (51 men and 38 women; age range, 23-83 years; median, 63.3 years) with an MDCT diagnosis of acute PE were included in the study. Sixty-four patients had a coexisting malignancy. PE severity was assessed by two masked observers using three percentage arterial obstruction indexes: two severity scores adapted from conventional angiography (excluding and including arterial branch obstruction grading: scores A and B, respectively) and a CT-derived severity score (index C). Echocardiographic reports were reviewed for elevation of right ventricular pressure. Obstruction index results were analyzed for correlation with pulmonary artery pressures and for prediction of cor pulmonale and 30-day survival. Statistical analysis included kappa, analysis of variance, linear correlation, chi-square, and logistic regression tests. RESULTS: Kappa values of 0.89, 0.82, and 0.78 were obtained for interobserver agreement on PE severity for indexes A, B, and C, respectively. PE severity was moderate but varied significantly between the scores (for index A: median, 25.0%; range, 6.3-100; for index B: median, 12.5%; range, 3.1-65.6; for index C: median, 7.1%; range, 0.65-65.8; p < 0.0001 [analysis of variance]). Index C correlated best with pulmonary artery pressures (r = 0.69; p < 0.0016) and the presence of cor pulmonale (p = 0.0051; odds ratio [OR], 1.20/percentage increase [95% confidence interval, 1.05-1.35]; for an index C cutoff of 21.3%: p = 0.0001; positive predictive value, 1; negative predictive value, 0.87). Eight patients died within 30 days after CT. The PE severity of indexes A and B was not associated with patient outcome (p > 0.05). With score C, PE severity was a significant predictor of early death (p = 0.018; OR, 1.03/percentage increase [95% confidence interval, 1.00-1.06]; for an index C cutoff of 21.3%: p = 0.018; overall OR, 6.77; positive predictive value, 0.24; negative predictive value, 0.96). CONCLUSION: Mastora score was a significant predictor of cor pulmonale and short-term outcome and may therefore allow therapy and risk stratification in patients with acute PE.


Assuntos
Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Doença Cardiopulmonar/etiologia , Tomografia Computadorizada por Raios X , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo
8.
Radiology ; 239(2): 563-75, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16569782

RESUMO

PURPOSE: To retrospectively assess outcome in patients with clinically unsuspected pulmonary embolism (PE) at chest multi-detector row computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed consent were not required. PE was assessed in consecutive CT scans in 1966 patients (mean age, 60 years; range, 15-96 years; male-female ratio, 1.79) and graded with severity score. Studies with true-positive and false-negative radiologic diagnoses were determined. Coexisting morbidity, anticoagulant therapy (ACT), complications, and 1-year outcome were reviewed. Statistical evaluation included Mann-Whitney U test, chi(2) test, Poisson regression, and Kaplan-Meier statistics. RESULTS: Scans were PE positive in 117 patients. Clinical data review was complete in 96 patients; 63 of 96 patients had malignancy; in 58, PE was not suspected. In 38 of these 58 patients, radiology report findings were false-negative (mean severity score, 20.21 +/- 17.88 [standard deviation] and 9.55 +/- 7.12 for those with true-positive and false-negative findings, respectively; P = .012). Forty-nine patients received therapeutic ACT; 21, prophylactic ACT; and 26, no treatment. PE severity was higher in patients with therapeutic ACT versus those without (P < .001). Bleeding complications were more frequent with therapeutic ACT (two early deaths, five major nonfatal hemorrhages) than without (one minor hemorrhage; P = .037). There were eight early deaths (therapeutic ACT, seven; without ACT, one; P = .037). Positive predictors of early death included severity score >28, use of systemic thrombolytic therapy, occurrence of major hemorrhage, and new-onset cardiac or renal failure (P = .001-.043). Negative predictors were report with false-negative findings and no therapeutic ACT (P = .007-.037). Predictors of late death (n = 25) were older age, malignancy, and renal failure (P = .001-.043). CONCLUSION: Clinically unsuspected PE may remain undetected at routine chest CT; these patients have favorable short-term outcome without therapeutic ACT.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/mortalidade , Embolia Pulmonar/terapia , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo
9.
Eur Radiol ; 16(4): 781-90, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16331462

RESUMO

The purpose of this study was to compare relative values of manual unidimensional measurements (MD) and automated volumetry (AV) for longitudinal treatment response assessment in patients with pulmonary metastases. Fifty consecutive patients with pulmonary metastases and repeat chest multidetector-row CT (median interval=2 months) were independently assessed by two radiologists for treatment response using Response Evaluation Criteria In Solid Tumours (RECIST). Statistics included relative measurement errors (RME), intra-/interobserver correlations, limits of agreement (95% LoA), and kappa. A total of 202 metastases (median volume=182.22 mm(3); range=3.16-5,195.13 mm(3)) were evaluated. RMEs were significantly higher for MD than for AV (intraobserver RME=2.34-3.73% and 0.15-0.22% for MD and AV respectively; P<0.05. Interobserver RME=3.53-3.76% and 0.22-0.29% for MD and AV respectively; P<0.05). Overall correlation was significantly better for AV than for MD (P<0.05). Intraobserver 95% LoAs were -1.85 to 1.75 mm for MD and -11.28 to 9.84 mm(3) for AV. The interobserver 95% LoA were -1.46 to 1.92 mm for MD and -11.17 to 9.33 mm(3) for AV. There was total intra-/interobserver agreement on response using AV (kappa=1). MD intra- and interobserver agreements were 0.73-0.84 and 0.77-0.80 respectively. Of the 200 MD response ratings, 28 (14/50 patients) were discordant. Agreement using MD dropped significantly from total remission to progressive disease (P<0.05). We therefore conclude that AV allows for better reproducibility of response evaluation in pulmonary metastases and should be preferred to MD in these patients.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/classificação , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Análise de Variância , Feminino , Humanos , Modelos Lineares , Estudos Longitudinais , Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/terapia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Reprodutibilidade dos Testes , Software
10.
Radiology ; 234(3): 776-84, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15734933

RESUMO

PURPOSE: To evaluate the influence of different detector radiation doses and peak kilovoltage settings on diagnostic performance and radiation dose at posteroanterior (PA) chest radiography performed with an amorphous silicon flat-panel detector (FPD). MATERIALS AND METHODS: All examinations were performed by using a digital FPD. PA chest radiographs of an anthropomorphic chest phantom were obtained with detector radiation doses of 2.50 microGy (system speed, 400), 1.56 microGy (speed, 640), and 1.25 microGy (speed, 800) and with peak kilovoltage values of 100, 120, and 140 kVp. Four types of simulated lesions-nodules of different sizes, polylobulated lesions, interstitial-nodular lesions, and interstitial-reticular lesions-were superimposed on the phantom. After four radiologists assessed all of the images, receiver operating characteristics analysis was performed. In addition, the entrance surface dose was measured and the effective dose was calculated. RESULTS: Reduced detector dose led to significantly decreased diagnostic performance in overall lesion detection (P <.05). However, over pulmonary areas only, this effect could not be seen. With use of the same kilovoltage values, reducing the detector dose, even to 1.25 microGy (speed, 800), did not lead to significantly decreased lesion detectability. In terms of diagnostic performance and effective dose, 120 kVp was the most effective. CONCLUSION: Standard PA chest radiographs should still be acquired at a detector dose of 2.50 microGy (speed, 400) with 120 kVp to yield the highest diagnostic performance. However, when the present analysis was focused on the lung fields only, no significant loss in diagnostic performance could be demonstrated, even after a 50% reduction in radiation dose.


Assuntos
Radiografia Torácica/instrumentação , Ecrans Intensificadores para Raios X , Variações Dependentes do Observador , Imagens de Fantasmas , Curva ROC , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação , Silício
12.
Eur Radiol ; 15(2): 203-12, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15578184

RESUMO

The purpose of this study was to evaluate the performance of a computer-assisted diagnostic (CAD) tool using various reconstruction slice thicknesses (RST). Image data of 20 patients undergoing multislice CT for pulmonary metastasis were reconstructed at 4.0, 2.0 and 0.75 mm RST and assessed by two blinded radiologists (R1 and R2) and CAD. Data were compared against an independent reference standard. Nodule subgroups (diameter >10, 4-10, <4 mm) were assessed separately. Statistical methods were the ROC analysis and Mann-Whitney U test. CAD was outperformed by readers at 4.0 mm (Az = 0.18, 0.62 and 0.69 for CAD, R1 and R2, respectively; P<0.05), comparable at 2.0 mm (Az = 0.57, 0.70 and 0.69 for CAD, R1 and R2, respectively), and superior using 0.75 mm RST (Az = 0.80, 0.70 and 0.70 and sensitivity = 0.74, 0.53 and 0.53 for CAD, R1 and R2, respectively; P<0.05). Reader performances were significantly enhanced by CAD (Az = 0.93 and 0.95 for R1 + CAD and R2 + CAD, respectively, P<0.05). The CAD advantage was best for nodules <10 mm (detection rates = 93.3, 89.9, 47.9 and 47.9% for R1 + CAD, R2 + CAD, R1 and R2, respectively). CAD using 0.75 mm RST outperformed radiologists in nodules below 10 mm in diameter and should be used to replace a second radiologist. CAD is not recommended for 4.0 mm RST.


Assuntos
Diagnóstico por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas Inteligentes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Radiografia Torácica , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
13.
J Thorac Imaging ; 19(3): 156-63, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15273611

RESUMO

PURPOSE: To evaluate amorphous silicone-based flat panel detector volumetric CT (VCT) in volumetric assessment of small nodules in a pulmonary phantom, and to perform comparative experiments with 4-row multislice CT (MSCT). MATERIALS AND METHODS: Seventy synthetic nodules (volume range (VR): 0.99-185.77 mm; estimated diameter range (ED): 1.4-7.8 mm) were scanned in spherical shape and after iso-volumetric deformation with VCT and MSCT using 0.63 mm (MSCT I) and 1.25 mm (MSCT II) collimations. Measured volumes and percent measurement errors (PME) were compared between the 3 CT modes before and after nodule deformation. For each measurement pair before and after deformation, the post-deformation relative volumetric inaccuracy (RIA) was determined. Volume, PME, and RIA differences were tested using Wilcoxon and Friedman methods. RESULTS: The volumes of the smallest nodules (VR = 0.99-2.83 mm, ED = 1.4-1.9 mm) were computable only from VCT scans. In VCT, measured volumes and PMEs before and after deformation differed significantly less compared with MSCT (VCT: P = 0.06 and 0.56, respectively; MSCT I: P = 0.0012 and 0.006, respectively; and MSCT II: P < 0.0001 for measured volumes and PMEs). In VCT PMEs of 5.51-32.21 mm nodules (ED = 2.4-4.1 mm) before and after deformation were significantly below MSCT (VCT averages = 1.43-1.91% and 1.98-3.48%, for spherical and deformed nodules, respectively; MSCT I averages = 9.97-26.1% and 12.16-38.10%, respectively; MSCT II averages = 17.79-46.18 and 18.14-54.66%, respectively, P < 0.0001) and RIAs in VCT were significantly below MSCT (VCT: 0.50-2.62%, MSCT I: 3.35-15.97%, and MSCT II: 4.29-18.46%; P = 0.0001-0.0039). CONCLUSION: VCT volumetry is highly accurate in volumetry of smallest nodules with estimated diameters of 1.4-4.1 mm.


Assuntos
Pulmão/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomógrafos Computadorizados , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
14.
Eur Radiol ; 14(10): 1930-8, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15235812

RESUMO

To evaluate the performance of experienced versus inexperienced radiologists in comparison and in consensus with an interactive computer-aided detection (CAD) system for detection of pulmonary nodules. Eighteen consecutive patients (mean age: 62.2 years; range 29-83 years) prospectively underwent routine 16-row multislice computed tomography (MSCT). Four blinded radiologists (experienced: readers 1, 2; inexperienced: readers 3, 4) assessed image data against CAD for pulmonary nodules. Thereafter, consensus readings of readers 1+3, reader 1+CAD and reader 3+CAD were performed. Data were compared against an independent gold standard. Statistical tests used to calculate interobserver agreement, reader performance and nodule size were Kappa, ROC and Mann-Whitney U. CAD and experienced readers outperformed inexperienced readers (Az=0.72, 0.71, 0.73, 0.49 and 0.50 for CAD, readers 1-4, respectively; P<0.05). Performance of reader 1+CAD was superior to single reader and reader 1+3 performances (Az=0.93, 0.72 for reader 1+CAD and reader 1+3 consensus, respectively, P<0.05). Reader 3+CAD did not perform superiorly to experienced readers or CAD (Az=0.79 for reader 3+CAD; P>0.05). Consensus of reader 1+CAD significantly outperformed all other readings, demonstrating a benefit in using CAD as an inexperienced reader replacement. It is questionable whether inexperienced readers can be regarded as adequate for interpretation of pulmonary nodules in consensus with CAD, replacing an experienced radiologist.


Assuntos
Diagnóstico por Computador , Sistemas Inteligentes , Iohexol/análogos & derivados , Neoplasias Pulmonares/diagnóstico por imagem , Radiologia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Método Simples-Cego , Estatísticas não Paramétricas
15.
Eur Radiol ; 12(12): 2895-7, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12439567

RESUMO

We describe a patient with inactive systemic lupus erythematosus (SLE) presenting with sudden haemothorax, due to a ruptured internal mammary artery (IMA) aneurysm 7 years after the corticosteroid treatment was terminated. The unusual imaging findings and the treatment with embolization are discussed with a view to the role of a regular vascular screening in this patient group.


Assuntos
Aneurisma Roto/etiologia , Lúpus Eritematoso Sistêmico/complicações , Doenças Vasculares Periféricas/etiologia , Aneurisma Roto/diagnóstico , Feminino , Humanos , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/lesões , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler em Cores
16.
AJR Am J Roentgenol ; 179(3): 619-23, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12185029

RESUMO

OBJECTIVE: The objective of this study was to assess the efficacy of 6-mm Cutting Balloon angioplasty in patients with resistant peripheral stenoses caused by neointimal hyperplasia or irradiation-induced arteriopathy in vascular territories that are not amenable for use of the smaller Cutting Balloons that are used in cardiology. CONCLUSION: Peripheral Cutting Balloon angioplasty with the new 6-mm Cutting Balloon device proved useful in the short term for treatment of peripheral arterial stenoses resistant to conventional angioplasty.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/terapia , Doenças Vasculares Periféricas/terapia , Adulto , Idoso , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/terapia , Desenho de Equipamento , Feminino , Humanos , Hiperplasia/complicações , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/etiologia , Projetos Piloto , Estudos Prospectivos , Radiografia , Radioterapia/efeitos adversos
17.
J Vasc Interv Radiol ; 13(7): 667-76, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12119323

RESUMO

PURPOSE: To retrospectively evaluate the clinical outcome of patients after simultaneous or sequential internal iliac artery (IIA) embolization for bilateral IIA occlusion. MATERIALS AND METHODS: Sixteen patients (65-88 y; mean, 75.6 y; two women), 11 with aortobiiliac aneurysms, three with bilateral common iliac artery (CIA)/IIA aneurysms, and two with unilateral CIA/IIA aneurysms, underwent IIA occlusion before endovascular aortoiliac repair. Eight patients underwent simultaneous bilateral IIA embolization before endovascular aortic repair (EVAR). Eight patients had sequential bilateral IIA occlusion. The outcome was assessed by clinical follow-up. RESULTS: There were no severe ischemic complications such as buttock necrosis or acute bowel, bladder, or spinal cord ischemia. Early ischemic complications occurred in 25% (buttock/thigh claudication, n = 3, 18.8%; and sexual dysfunction, n = 1, 6.2%) and had an onset not later than 6 months after intervention: buttock claudication resolved (n = 2) or persisted after aggravation by inferior mesenteric artery embolization for type II endoleak (n = 1). Impotence in a fourth patient persisted. The ischemic complication rate after 6 months was 30% (three of 10) because of a fifth patient who developed ischemic colitis with aggravation of ischemic heart disease after 15 months. The mean follow-up duration was 19.7 months. Patients with simultaneous embolization had a lower complication rate than those with sequential embolization (one of eight [12.5%] vs four of eight [50%], respectively). CONCLUSIONS: IIA embolization for bilateral IIA occlusion can be performed with a complication rate comparable with results of previous studies of unilateral IIA embolization. Chronic buttock claudication may be aggravated by embolization of aortic side branches. Late complications can have an insidious course and be initiated by low-output cardiac failure. Bilateral IIA occlusion is recommended only in patients who are considered unfit for aortic surgery.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Embolização Terapêutica/métodos , Aneurisma Ilíaco/terapia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/terapia , Feminino , Humanos , Aneurisma Ilíaco/complicações , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
18.
Radiographics ; 22(4): 739-64, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12110707

RESUMO

Peripheral pulmonary vascular disorders that can be evaluated with computed tomography (CT) include various disease entities with overlapping imaging features and a wide range of clinical manifestations. The overall accuracy of CT in the diagnosis of pulmonary vascular disorders increases with improved spatial resolution, administration of a high-flow contrast material bolus, and the use of cardiac gating. The integration of high-resolution CT and CT angiographic techniques into one scanning protocol has important clinical implications for multisection CT and makes it the imaging modality of choice in the evaluation of this complex group of disorders.


Assuntos
Angiografia/métodos , Pneumopatias/diagnóstico por imagem , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos
19.
J Vasc Interv Radiol ; 13(6): 625-9, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12050304

RESUMO

An 80-year-old woman with established giant cell arteritis presented at the authors' institution with a 6.5-cm false aneurysm of the descending thoracic aorta complicated by focal dissection and intramural hematoma after a 1-week history of acute-onset chest pain. The patient underwent uncomplicated endovascular aortic repair with a 32-mm x 15-cm TagExcluder stent-graft. After the procedure, the intramural hematoma resolved and the patient's corticosteroid and immunosuppressive therapy was repeatedly adjusted. However, the giant cell arteritis activity relapsed after 8 months with development of a similar 1.5-cm false aneurysm below the thoracic stent-graft, complicated by focal intramural hematoma. Repeat uncomplicated thoracic stent-graft implantation was performed and CT follow-up displayed resorption of the intramural hematomas with no evidence of endoleak or any new aortic pathology. This report discusses the difficult management of patients with relapsing active aortic giant cell arteritis and the potential role for endovascular thoracic aortic repair.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/terapia , Arterite de Células Gigantes/patologia , Hematoma/diagnóstico por imagem , Hematoma/terapia , Stents , Idoso , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Angiografia , Feminino , Humanos , Recidiva , Tomografia Computadorizada por Raios X
20.
Radiology ; 223(1): 106-14, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11930054

RESUMO

PURPOSE: To evaluate the feasibility of cutting balloon percutaneous transluminal angioplasty (PTA) for treatment of neointimal hyperplasia in peripheral arterial bypass grafts. MATERIALS AND METHODS: Fifteen consecutive patients (six women, nine men; age range, 57-89 years; mean age, 71 years) were treated with cutting balloon PTA for 16 anastomotic stenoses after infrainguinal bypass (prosthetic grafts, seven patients; prosthetic-vein composite grafts, two; venous grafts, five; and ileofemoral stent-graft, one). Cutting balloon PTA was followed by conventional PTA to improve anastomotic diameter. Patients with stenotic vein grafts underwent cutting balloon PTA after failed conventional PTA; the other patients were treated primarily with cutting balloon PTA. Criteria for success were a lumen diameter improvement of greater than 50% or residual stenosis of 20% or less. Follow-up was performed with color duplex ultrasonographic surveillance. Patency rates and durations were calculated with Kaplan-Meier survival curves and log-rank statistics. RESULTS: Attempted conventional PTA (n = 6) prior to cutting balloon PTA was unsuccessful. Cutting balloon PTA was technically successful in 15 (94%) of 16 lesions, without clinical complications. Two local restenoses and one graft occlusion occurred between 5 and 7 months. The cumulative 6-month primary and secondary graft patency rates were 84% and 92%, respectively. At 12 and 18 months, they were 67% (95% CI: 0.34, 0.86) and 83% (95% CI: 0.48, 0.96), respectively; mean follow-up was 10.0 months. CONCLUSION: Cutting balloon PTA proved feasible for treatment of resistant peripheral arterial bypass graft stenosis, commonly caused by neointimal hyperplasia, with excellent technical success. Short-term patency with this technique appears to be superior to that with conventional PTA, and it compares well with patency of atherectomy for salvage of infrainguinal bypass grafts.


Assuntos
Angioplastia com Balão , Oclusão de Enxerto Vascular/cirurgia , Perna (Membro)/irrigação sanguínea , Perna (Membro)/cirurgia , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...