Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Res ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38966925

RESUMO

Several scientific themes are reviewed in the context of the 75-year period relevant to this special platinum issue of Radiation Research. Two criteria have been considered in selecting the scientific themes. One is the exposure of the associated research activity in the annual meetings of the Radiation Research Society (RRS) and in the publications of the Society's Journal, thus reflecting the interest of members of RRS. The second criteria is a focus on contributions from Australian members of RRS. The first theme is the contribution of radiobiology to radiation oncology, featuring two prominent Australian radiation oncologists, the late Rod Withers and his younger colleague, Lester Peters. Two other themes are also linked to radiation oncology; preclinical research aimed at developing experimental radiotherapy modalities, namely microbeam radiotherapy (MRT) and Auger endoradiotherapy. The latter has a long history, in contrast to MRT, especially in Australia, given that the associated medical beamline at the Australian Synchrotron in Melbourne only opened in 2011. Another theme is DNA repair, which has a trajectory parallel to the 75-year period of interest, given the birth of molecular biology in the 1950s. The low-dose radiobiology theme has a similar timeline, predominantly prompted by the nuclear era, which is also connected to the radioprotector theme, although radioprotectors also have a long-established potential utility in cancer radiotherapy. Finally, two themes are associated with biodosimetry. One is the micronucleus assay, highlighting the pioneering contribution from Michael Fenech in Adelaide, South Australia, and the other is the γ-H2AX assay and its widespread clinical applications.

2.
Phys Med Biol ; 69(14)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38914107

RESUMO

Objective.This study aims to design, manufacture, and test 3D printed quality assurance (QA) dosimetry phantoms for synchrotron brain cancer radiation therapy at the Australian synchrotron.Approach.Fabricated 3D printed phantoms from simple slab phantoms, a preclinical rat phantom, and an anthropomorphic head phantom were fabricated and characterized. Attenuation measurements of various polymers, ceramics and metals were acquired using synchrotron monochromatic micro-computed tomography (CT) imaging. Polylactic acid plus, VeroClear, Durable resin, and tricalcium phosphate were used in constructing the phantoms. Furthermore, 3D printed bone equivalent materials were compared relative to ICRU bone and hemihydrate plaster. Homogeneous and heterogeneous rat phantoms were designed and fabricated using tissue-equivalent materials. Geometric accuracy, CT imaging, and consistency were considered. Moreover, synchrotron broad-beam x-rays were delivered using a 3 Tesla superconducting multipole wiggler field for four sets of synchrotron radiation beam qualities. Dose measurements were acquired using a PinPoint ionization chamber and compared relative to a water phantom and a RMI457 Solid Water phantom. Experimental depth doses were compared relative to calculated doses using a Geant4 Monte Carlo simulation.Main results.Polylactic acid (PLA+) shows to have a good match with the attenuation coefficient of ICRU water, while both tricalcium phosphate and hydroxyapatite have good attenuation similarity with ICRU bone cortical. PLA+ material can be used as substitute to RMI457 slabs for reference dosimetry with a maximum difference of 1.84%. Percent depth dose measurement also shows that PLA+ has the best match with water and RMI457 within ±2.2% and ±1.6%, respectively. Overall, PLA+ phantoms match with RMI457 phantoms within ±3%.Significance and conclusion.The fabricated phantoms are excellent tissue equivalent equipment for synchrotron radiation dosimetry QA measurement. Both the rat and the anthropomorphic head phantoms are useful in synchrotron brain cancer radiotherapy dosimetry, experiments, and future clinical translation of synchrotron radiotherapy and imaging.


Assuntos
Neoplasias Encefálicas , Imagens de Fantasmas , Impressão Tridimensional , Radiometria , Síncrotrons , Ratos , Animais , Radiometria/instrumentação , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagem , Dosagem Radioterapêutica , Método de Monte Carlo , Garantia da Qualidade dos Cuidados de Saúde , Desenho de Equipamento
3.
Biomimetics (Basel) ; 8(2)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37366825

RESUMO

The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

4.
Cancers (Basel) ; 15(9)2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37173938

RESUMO

Microbeam radiotherapy (MRT), a high dose rate radiotherapy technique using spatial dose fractionation at the micrometre range, has shown a high therapeutic efficacy in vivo in different tumour entities, including lung cancer. We have conducted a toxicity study for the spinal cord as organ of risk during irradiation of a target in the thoracic cavity. In young adult rats, the lower thoracic spinal cord was irradiated over a length of 2 cm with an array of quasi-parallel microbeams of 50 µm width, spaced at a centre-to-centre distance of 400 µm, with MRT peak doses up to 800 Gy. No acute or subacute adverse effects were observed within the first week after irradiation up to MRT peak doses of 400 Gy. No significant differences were seen between irradiated animals and non-irradiated controls in motor function and sensitivity, open field test and somatosensory evoked potentials (SSEP). After irradiation with MRT peak doses of 450-800 Gy, dose-dependent neurologic signs occurred. Provided that long-term studies do not reveal significant morbidity due to late toxicity, an MRT dose of 400 Gy can be considered safe for the spinal cord in the tested beam geometry and field size.

5.
Cancers (Basel) ; 15(7)2023 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-37046798

RESUMO

Microbeam radiation therapy (MRT) utilizes coplanar synchrotron radiation beamlets and is a proposed treatment approach for several tumor diagnoses that currently have poor clinical treatment outcomes, such as gliosarcomas. Monte Carlo (MC) simulations are one of the most used methods at the Imaging and Medical Beamline, Australian Synchrotron to calculate the dose in MRT preclinical studies. The steep dose gradients associated with the 50µm-wide coplanar beamlets present a significant challenge for precise MC simulation of the dose deposition of an MRT irradiation treatment field in a short time frame. The long computation times inhibit the ability to perform dose optimization in treatment planning or apply online image-adaptive radiotherapy techniques to MRT. Much research has been conducted on fast dose estimation methods for clinically available treatments. However, such methods, including GPU Monte Carlo implementations and machine learning (ML) models, are unavailable for novel and emerging cancer radiotherapy options such as MRT. In this work, the successful application of a fast and accurate ML dose prediction model for a preclinical MRT rodent study is presented for the first time. The ML model predicts the peak doses in the path of the microbeams and the valley doses between them, delivered to the tumor target in rat patients. A CT imaging dataset is used to generate digital phantoms for each patient. Augmented variations of the digital phantoms are used to simulate with Geant4 the energy depositions of an MRT beam inside the phantoms with 15% (high-noise) and 2% (low-noise) statistical uncertainty. The high-noise MC simulation data are used to train the ML model to predict the energy depositions in the digital phantoms. The low-noise MC simulations data are used to test the predictive power of the ML model. The predictions of the ML model show an agreement within 3% with low-noise MC simulations for at least 77.6% of all predicted voxels (at least 95.9% of voxels containing tumor) in the case of the valley dose prediction and for at least 93.9% of all predicted voxels (100.0% of voxels containing tumor) in the case of the peak dose prediction. The successful use of high-noise MC simulations for the training, which are much faster to produce, accelerates the production of the training data of the ML model and encourages transfer of the ML model to different treatment modalities for other future applications in novel radiation cancer therapies.

6.
J Synchrotron Radiat ; 29(Pt 4): 1027-1032, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787570

RESUMO

Microbeam radiotherapy could help to cure malignant tumours which are currently still considered therapy-resistant. With an irradiation target in the thoracic cavity, the heart would be one of the most important organs at risk. To assess the acute adverse effects of microbeam irradiation in the heart, a powerful ex vivo tool was created by combining the Langendorff model of the isolated beating mammalian heart with X-Tream dosimetry. In a first pilot experiment conducted at the Biomedical and Imaging Beamline of the Australian Synchrotron, the system was tested at a microbeam peak dose approximately ten times higher than the anticipated future microbeam irradiation treatment doses. The entire heart was irradiated with a dose of 4000 Gy at a dose rate of >6000 Gy s-1, using an array of 50 µm-wide microbeams spaced at a centre-to-centre distance of 400 µm. Although temporary arrhythmias were seen, they reverted spontaneously to a stable rhythm and no cardiac arrest occurred. This amazing preservation of cardiac function is promising for future therapeutic approaches.


Assuntos
Radiometria , Síncrotrons , Animais , Austrália , Mamíferos , Radiometria/métodos
7.
Mater Sci Eng C Mater Biol Appl ; 123: 111970, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33812598

RESUMO

Nanoparticles have a great potential to increase the therapeutic efficiency of several cancer therapies. This research examines the potential for silver-doped lanthanum manganite nanoparticles to enhance radiation therapy to target radioresistant brain cancer cells, and their potential in combinational therapy with magnetic hyperthermia. Magnetic and structural characterisation found all dopings of nanoparticles (NPs) to be pure and single phase with an average crystallite size of approximately 15 nm for undoped NPs and 20 nm for silver doped NPs. Additionally, neutron diffraction reveals that La0.9Ag0.1MnO3 (10%-LAGMO) NPs exhibit residual ferromagnetism at 300 K that is not present in lower doped NPs studied in this work, indicating that the Curie temperature may be manipulated according to silver doping. This radiobiological study reveals a completely cancer-cell selective treatment for LaMnO3, La0.975Ag0.025MnO3 and La0.95Ag0.05MnO3 (0, 2.5 and 5%-LAGMO) and also uncovers a potent combination of undoped lanthanum manganite with orthovoltage radiation. Cell viability assays and real time imaging results indicated that a concentration of 50 µg/mL of the aforementioned nanoparticles do not affect the growth of Madin-Darby Canine Kidney (MDCK) non-cancerous cells over time, but stimulate its metabolism for overgrowth, while being highly toxic to 9L gliosarcoma (9LGS). This is not the case for 10%-LAGMO nanoparticles, which were toxic to both non-cancerous and cancer cell lines. The nanoparticles also exhibited a level of toxicity that was regulated by the overproduction of free radicals, such as reactive oxygen species, amplified when silver ions are involved. With the aid of fluorescent imaging, the drastic effects of these reactive oxygen species were visualised, where nucleus cleavage (an apoptotic indicator) was identified as a major consequence. The genotoxic response of this effect for 9LGS and MDCK due to 10%-LAGMO NPs indicates that it is also causing DNA double strand breaks within the cell nucleus. Using 125 kVp orthovoltage radiation, in combination with an appropriate amount of NP-induced cell death, identified undoped lanthanum manganite as the most ideal treatment. Real-time imaging following the combination treatment of undoped lanthanum manganite nanoparticles and radiation, highlighted a hinderance of growth for 9LGS, while MDCK growth was boosted. The clonogenic assay following incubation with undoped lanthanum manganite nanoparticles combined with a relatively low dose of radiation (2 Gy) decreased the surviving fraction to an exceptionally low (0.6 ± 6.7)%. To our knowledge, these results present the first biological in-depth analysis on silver-doped lanthanum manganite as a brain cancer selective chemotherapeutic and radiation dose enhancer and as a result will propel its first in vivo investigation.


Assuntos
Nanopartículas Metálicas , Prata , Animais , Cães , Lantânio/toxicidade , Compostos de Manganês , Nanopartículas Metálicas/toxicidade
8.
Phys Med Biol ; 65(22): 225017, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-32916674

RESUMO

Gold nanoparticles have demonstrated significant radiosensitization of cancer treatment with x-ray radiotherapy. To understand the mechanisms at the basis of nanoparticle radiosensitization, Monte Carlo simulations are used to investigate the dose enhancement, given a certain nanoparticle concentration and distribution in the biological medium. Earlier studies have ordinarily used condensed history physics models to predict nanoscale dose enhancement with nanoparticles. This study uses Geant4-DNA complemented with novel track structure physics models to accurately describe electron interactions in gold and to calculate the dose surrounding gold nanoparticle structures at nanoscale level. The computed dose in silico due to a clinical kilovoltage beam and the presence of gold nanoparticles was related to in vitro brain cancer cell survival using the local effect model. The comparison of the simulation results with radiobiological experimental measurements shows that Geant4-DNA and local effect model can be used to predict cell survival in silico in the case of x-ray kilovoltage beams.


Assuntos
Ouro/química , Ouro/farmacologia , Nanopartículas Metálicas , Modelos Biológicos , Método de Monte Carlo , Radiossensibilizantes/química , Radiossensibilizantes/farmacologia , Simulação por Computador , Elétrons , Humanos
9.
Phys Med Biol ; 65(21): 215018, 2020 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-32726756

RESUMO

Metastases from cutaneous squamous cell carcinoma (cSCC) occur in 2%-5% of cases. Surgery is the standard treatment, often combined with adjuvant radiotherapy. Concurrent carboplatin treatment with post-operative radiotherapy may be prescribed, although it has not shown benefit in recent clinical trials in high-risk cSCC patients. The novel high-Z nanoparticle thulium (III) oxide has been shown to enhance radiation dose delivery to brain tumors by specific uptake of these nanoparticles into the cancerous tissue. As the dose-enhancement capacity of thulium oxide nanoparticles following radiotherapy against metastatic cSCC cells is unknown, its efficacy as a radiosensitizer was evaluated, with and without carboplatin. Novel and validated human patient-derived cell lines of metastatic cSCC were used. The sensitivity of the cells to radiation was investigated using short-term proliferation assays as well as clonogenic survival as the radiobiological endpoint. Briefly, cells were irradiated with 125 kVp orthovoltage x-rays (0-6 Gy) with and without thulium oxide nanoparticles (99.9% trace metals basis; 50 µg ml-1) or low dose carboplatin pre-sensitization. Cellular uptake of the nanoparticles was first confirmed by microscopy and found to have no impact on short-term cell survival for the cSCC cells, highlighting the biocompatibility of thulium oxide nanoparticles. Clonogenic cell survival assays confirmed radio-sensitization when exposed to thulium nanoparticles, with the cell sensitivity increasing by a factor of 1.24 (calculated at the 10% survival fraction) for the irradiated cSCC cells. The combination of carboplatin with thulium oxide nanoparticles with irradiation did not result in significant further reductions in survival compared to nanoparticles alone. This is the first study to provide in vitro data demonstrating the independent radiosensitization effect of high-Z nanoparticles against metastatic cSCC with or without carboplatin. Further preclinical investigations with radiotherapy plus high-Z nanoparticles for the management of metastatic cSCC are warranted.


Assuntos
Carcinoma de Células Escamosas/patologia , Nanopartículas , Radiossensibilizantes/química , Radiossensibilizantes/farmacologia , Neoplasias Cutâneas/patologia , Túlio/química , Túlio/farmacologia , Humanos , Metástase Neoplásica , Estadiamento de Neoplasias
10.
Sci Rep ; 10(1): 8833, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32483249

RESUMO

Synchrotron facilities produce ultra-high dose rate X-rays that can be used for selective cancer treatment when combined with micron-sized beams. Synchrotron microbeam radiation therapy (MRT) has been shown to inhibit cancer growth in small animals, whilst preserving healthy tissue function. However, the underlying mechanisms that produce successful MRT outcomes are not well understood, either in vitro or in vivo. This study provides new insights into the relationships between dosimetry, radiation transport simulations, in vitro cell response, and pre-clinical brain cancer survival using intracerebral gliosarcoma (9LGS) bearing rats. As part of this ground-breaking research, a new image-guided MRT technique was implemented for accurate tumor targeting combined with a pioneering assessment of tumor dose-coverage; an essential parameter for clinical radiotherapy. Based on the results of our study, we can now (for the first time) present clear and reproducible relationships between the in vitro cell response, tumor dose-volume coverage and survival post MRT irradiation of an aggressive and radioresistant brain cancer in a rodent model. Our innovative and interdisciplinary approach is illustrated by the results of the first long-term MRT pre-clinical trial in Australia. Implementing personalized synchrotron MRT for brain cancer treatment will advance this international research effort towards clinical trials.


Assuntos
Neoplasias Encefálicas/radioterapia , Gliossarcoma/radioterapia , Animais , Encéfalo/patologia , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/patologia , Modelos Animais de Doenças , Gliossarcoma/mortalidade , Gliossarcoma/patologia , Masculino , Ratos , Ratos Endogâmicos F344 , Taxa de Sobrevida , Síncrotrons , Microtomografia por Raio-X , Raios X
11.
Phys Med ; 32(12): 1852-1861, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27866898

RESUMO

Microbeam Radiation Therapy (MRT) exploits tumour selectivity and normal tissue sparing with spatially fractionated kilovoltage X-ray microbeams through the dose volume effect. Experimental measurements with Ta2O5 nanoparticles (NPs) in 9L gliosarcoma treated with MRT at the Australian Synchrotron, increased the treatment efficiency. Ta2O5 NPs were observed to form shells around cell nuclei which may be the reason for their efficiency in MRT. In this article, our experimental observation of NP shell formation is the basis of a Geant4 radiation transport study to characterise dose enhancement by Ta2O5 NPs in MRT. Our study showed that NP shells enhance the physical dose depending microbeam energy and their location relative to a single microbeam. For monochromatic microbeam energies below ∼70keV, NP shells show highly localised dose enhancement due to the short range of associated secondary electrons. Low microbeam energies indicate better targeted treatment by allowing higher microbeam doses to be administered to tumours and better exploit the spatial fractionation related selectivity observed with MRT. For microbeam energies above ∼100keV, NP shells extend the physical dose enhancement due to longer-range secondary electrons. Again, with NPs selectively internalised, the local effectiveness of MRT is expected to increase in the tumour. Dose enhancement produced by the shell aggregate varied more significantly in the cell population, depending on its location, when compared to a homogeneous NP distribution. These combined simulation and experimental data provide first evidence for optimising MRT through the incorporation of newly observed Ta2O5 NP distributions within 9L cancer cells.


Assuntos
Microtecnologia/instrumentação , Nanopartículas , Óxidos/química , Óxidos/farmacologia , Doses de Radiação , Radioterapia/instrumentação , Síncrotrons , Tantálio/química , Tantálio/farmacologia , Neoplasias Encefálicas/radioterapia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Gliossarcoma/radioterapia , Humanos , Método de Monte Carlo , Radiossensibilizantes/química , Radiossensibilizantes/farmacologia , Dosagem Radioterapêutica
12.
Phys Med ; 32(10): 1216-1224, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27666955

RESUMO

The application of nanoparticles (NPs) in radiotherapy is an increasingly attractive technique to improve clinical outcomes. The internalisation of NPs within the tumour cells enables an increased radiation dose to critical cellular structures. The purpose of this study is to investigate, by means of Geant4 simulations, the dose enhancement within a cell population irradiated with a 150kVp photon field in the presence of a varying concentration of tantalum pentoxide (Ta2O5) NP aggregates, experimentally observed to form shells within tumour cells. This scenario is compared to the more traditionally simulated homogeneous solution of NP material in water with the same weight fraction of Ta2O5, as well as to a cell population without NPs present. The production of secondary electrons is enhanced by increased photoelectric effect interactions within the high-Z material and this is examined in terms of their kinetic energy spectra and linear energy transfer (LET) with various NP distributions compared to water. Our results indicate that the shell formation scenario limits the dose enhancement at 150kVp. The underlying mechanism for this limit is discussed.


Assuntos
Nanopartículas Metálicas/efeitos da radiação , Nanopartículas Metálicas/uso terapêutico , Óxidos , Tantálio , Animais , Fenômenos Biofísicos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos da radiação , Cerâmica , Simulação por Computador , Humanos , Transferência Linear de Energia , Nanopartículas Metálicas/química , Modelos Biológicos , Método de Monte Carlo , Neoplasias/radioterapia , Fótons/uso terapêutico , Dosagem Radioterapêutica , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...