1.
J Appl Crystallogr ; 51(Pt 2): 323-336, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29657566

RESUMO

A new detection system based on an array of 3He tubes and innovative fast detection electronics has been installed on the high-intensity small-angle neutron scattering (SANS) diffractometer KWS-2 operated by the Jülich Centre for Neutron Science (JCNS) at the Heinz Meier-Leibnitz Zentrum in Garching, Germany. The new detection system is composed of 18 eight-pack modules of 3He tubes that work independently of one another (each unit has its own processor and electronics). To improve the read-out characteristics and reduce the noise, the detection electronics are mounted in a closed case on the rear of the 3He tubes' frame. The tubes' efficiency is about 85% (for λ = 5 Å) and the resolution slightly better than 8 mm. The new detection system is characterized by a dead-time constant of 3.3 µs per tube and an overall count rate as high as 6 MHz at 10% dead-time loss. Compared with the old detector this is an improvement by a factor of 60. The much higher count rate will shorten the measurement times and thus increase the number of experiments possible in a given time period by the optimal use of the high flux of up to 2 × 108 n cm-2 s-1 at the sample position. Combined with the event-mode operation capability, this will enable new scientific opportunities in the field of structural investigations of small soft-matter and biological systems. The implementation of the detector in the high-intensity concept on KWS-2, its characterization and its performance based on test experiments are reported in this paper.

2.
J Vis Exp ; (118)2016 12 08.
Artigo em Inglês | MEDLINE | ID: mdl-28060296

RESUMO

The KWS-2 SANS diffractometer is dedicated to the investigation of soft matter and biophysical systems covering a wide length scale, from nm to µm. The instrument is optimized for the exploration of the wide momentum transfer Q range between 1x10-4 and 0.5 Å-1 by combining classical pinhole, focusing (with lenses), and time-of-flight (with chopper) methods, while simultaneously providing high-neutron intensities with an adjustable resolution. Because of its ability to adjust the intensity and the resolution within wide limits during the experiment, combined with the possibility to equip specific sample environments and ancillary devices, the KWS-2 shows a high versatility in addressing the broad range of structural and morphological studies in the field. Equilibrium structures can be studied in static measurements, while dynamic and kinetic processes can be investigated over time scales between minutes to tens of milliseconds with time-resolved approaches. Typical systems that are investigated with the KWS-2 cover the range from complex, hierarchical systems that exhibit multiple structural levels (e.g., gels, networks, or macro-aggregates) to small and poorly-scattering systems (e.g., single polymers or proteins in solution). The recent upgrade of the detection system, which enables the detection of count rates in the MHz range, opens new opportunities to study even very small biological morphologies in buffer solution with weak scattering signals close to the buffer scattering level at high Q. In this paper, we provide a protocol to investigate samples with characteristic size levels spanning a wide length scale and exhibiting ordering in the mesoscale structure using KWS-2. We present in detail how to use the multiple working modes that are offered by the instrument and the level of performance that is achieved.


Assuntos
Difração de Nêutrons/métodos , Géis/química , Nêutrons , Polímeros/química , Proteínas/química
3.
J Appl Crystallogr ; 48(Pt 6): 1849-1859, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26664343

RESUMO

Following demand from the user community regarding the possibility of improving the experimental resolution, the dedicated high-intensity/extended Q-range SANS diffractometer KWS-2 of the Jülich Centre for Neutron Science at the Heinz Maier-Leibnitz Center in Garching was equipped with a double-disc chopper with a variable opening slit window and time-of-flight (TOF) data acquisition option. The chopper used in concert with a dedicated high-intensity velocity selector enables the tuning at will of the wavelength resolution Δλ/λ within a broad range, from 20% (standard) down to 2%, in a convenient and safe manner following pre-planned or spontaneous decisions during the experiment. The new working mode is described in detail, and its efficiency is demonstrated on several standard samples with known properties and on a completely new crystallizable copolymer system, which were investigated using both the conventional (static) and TOF modes.

4.
Rev Sci Instrum ; 85(10): 103505, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25362391

RESUMO

Lamb-shift polarimeters are used to measure the nuclear polarization of protons and deuterons at energies of a few keV. In combination with an ionizer, the polarization of hydrogen and deuterium atoms was determined after taking into account the loss of polarization during the ionization process. The present work shows that the nuclear polarization of hydrogen or deuterium molecules can be measured as well, by ionizing the molecules and injecting the H2(+) (or D2(+)) ions into the Lamb-shift polarimeter.