Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Allergy Clin Immunol ; 90(6 Pt 1): 985-91, 1992 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1460202

RESUMO

Twenty volunteers were skin tested with seven concentrations of histamine phosphate and a glycerosaline control to determine the relative sensitivity and precision of four skin test devices: Greer Pen (GP), Greer DermaPIK (DP), Center Multi-Test (MT), and Morrow Brown needle (MB). The end points of the study were (1) wheal and flare response of each device, with a dose-response curve, (2) the time required to apply each set of eight tests, and (3) the volunteers' subjective assessment of each device. On a different day, 10 of the volunteers were tested to determine the precision of each device. Dose-response curves for half-log dilutions of histamine phosphate were produced with a glycerosaline control. The DP and GP induced wheal and flare responses discernible from that of the glycerosaline control at a lower concentration of histamine phosphate than the MB and MT. The DP took a shorter time to apply eight samples than any other device. The MB was preferred by the most volunteers, but any device tested on the upper half of the back was usually preferred over that tested on the lower half. When 5 mg/ml histamine phosphate was used, coefficients of variation for each device demonstrated that for wheals the precision of the DP, GP, and MT was similar (mean, 21.1%, 23.1%, and 24.5%, respectively). The MB was larger (mean, 59.9%). For flares, the precision of GP and DP was similar (mean, 22.0% and 23.5%, respectively), with the MT and MB larger (mean, 35.5% and 58.2%, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Testes Cutâneos/instrumentação , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
3.
Hosp Pract (Off Ed) ; 26(1): 105-8, 111-2, 1991 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-1670939

RESUMO

For diagnosis, a history and physical examination often suffice, but special studies may be useful. Treatment choices are avoidance, drugs, or immunotherapy. Efficacy, cost, and side effects are emphasized.


Assuntos
Rinite Alérgica Perene/diagnóstico , Corticosteroides/uso terapêutico , Dessensibilização Imunológica , Antagonistas dos Receptores Histamínicos H1/uso terapêutico , Humanos , Anamnese , Mucosa Nasal/citologia , Exame Físico , Teste de Radioalergoadsorção , Rinite Alérgica Perene/fisiopatologia , Rinite Alérgica Perene/terapia , Testes Cutâneos
4.
Tex Med ; 86(3): 4-5, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2333635
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...