Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Acta Radiol Open ; 4(6): 2058460115583034, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26346218

RESUMO

BACKGROUND: The risk for contrast-induced nephropathy (CIN) after intra-arterial application of an iodine-based contrast material is unknown for patients with chronic kidney disease (CKD) and peripheral arterial disease (PAD). PURPOSE: To investigate the incidence of CIN in patients with CKD and PAD. MATERIAL AND METHODS: This retrospective study was approved by the local ethics committee. One hundred and twenty patients with 128 procedures (73 with baseline eGFR in the range of 45-60 mL/min/1.73m(2), 55 with eGFR < 45 mL/min/1.73m(2)) were evaluated. All patients received intra-arterially an iodine-based low-osmolar contrast material (CM) after adequate intravenous hydration with isotonic NaCl 0.9% solution. CIN was defined as an increase in serum creatinine of more than 44 µmol/L within 4 days. The influence of patient-related risk factors (age, weight, body mass index, eGFR, serum creatinine, hypertension, diabetes mellitus, coronary heart disease, heart failure) and therapy-related risk factors (amount of CM, nephrotoxic drugs, number of CM applications) on CIN were examined. RESULTS: CIN developed in 0% (0/73) of procedures in patients with PAD and an eGFR in the range of 45-60 mL/min/1.73m(2) and in 10.9% (6/55) of procedures in patients with an eGFR <45 mL/min/1.73m(2). No risk factor significantly influenced the development of CIN, although baseline serum creatinine (P = 0.06) and baseline eGFR (P = 0.10) showed a considerable dependency. CONCLUSION: Patients with an eGFR in the range of 45-60 mL/min/1.73m(2) and PAD seem not at risk for CIN after intra-arterial CM application and adequate hydration. Whereas, an eGFR < 45 mL/min/1.73m(2) correlated with a risk of 10.9% for a CIN.

2.
Invest Radiol ; 43(10): 719-28, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18791414

RESUMO

OBJECTIVES: We evaluated the precision of multislice spiral computed tomography (MSCT) for the quantification of aortic valve stenosis in comparison with echocardiography and cardiac catheterization. MATERIALS AND METHODS: An electrocardiogram-gated MSCT scan (detector collimation 40 x 6.25 mm, gantry rotation time 420 milliseconds, pitch 0.2, tube voltage 120 KV, tube current 333 mA) was performed in 32 patients with known aortic valve stenosis. In each patient the aortic valve orifice area (AVA) was determined by planimetry on MSCT and compared with the results obtained from transthoracic Doppler echocardiography (using the continuity equation) and cardiac catheterization (using the Gorlin formula). RESULTS: Planimetry of the AVA on MSCT was feasible in all cases. The AVA on MSCT (1.11 +/- 0.49 cm2) was significantly larger compared with echocardiography (0.81 +/- 0.37 cm2, P < 0.001) and cardiac catheterization (0.87 +/- 0.45 cm2, P < 0.001). The correlations between MSCT and echocardiography (r = 0.86, limits of agreement +/-0.52 cm2) and also between MSCT and cardiac catheterization (r = 0.90, limits of agreement +/-0.44 cm2) were good, but inferior to the correlation between echocardiography and cardiac catheterization (r = 0.94, limits of agreement +/-0.32 cm2). Using an AVA of 1.0 cm at cardiac catheterization as reference standard, the best cut-off level for detecting severe-to-critical stenosis at MSCT was an AVA of 1.20 cm, resulting in a sensitivity, specificity, and accuracy of 91%, 100%, and 94%, respectively. CONCLUSIONS: AVA determined by MSCT correlates well with echocardiography and cardiac catheterization. However, AVA derived from MSCT is consistently larger, requiring an adjustment of cut-off values for the classification of stenosis severity and therapeutic decision making.


Assuntos
Estenose da Valva Aórtica/patologia , Cateterismo Cardíaco/instrumentação , Tomografia Computadorizada Espiral/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Ultrassonografia , Adulto Jovem
4.
J Comput Assist Tomogr ; 30(3): 386-90, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16778611

RESUMO

OBJECTIVE: We investigated the diagnostic yield of histological examined formalin-fixed blood clots (FFBCs) in comparison with the established procedures of fine-needle aspiration biopsy (FNAB) and core biopsy (CB) obtained by percutaneous puncture under computed tomography (CT) guidance. METHODS: A total of 76 CT-guided punctures with removal of tissue by means of all 3 different techniques (FFBC, FNAB, and CB) were performed. Specimens were obtained from the lung (n=18), mediastinum (n=10), upper abdominal organs (n=32), pelvis (n=4), retroperitoneum (n=4), bones (n=7), and neck (n=1). All results were correlated with the clinical course of the patients (minimum, 6 months; mean period, 10 months). The results of each technique were compared. Results of a combined use of FFBC and FNAB were analyzed. RESULTS: The overall sensitivity (regardless of biopsy site) was 79% for FFBC, 83% for FNAB, and 95% for CB. In chest biopsies, FFBC reached a sensitivity of 92%, FNAB of 86%, and CB of 96%. In liver biopsies, the sensitivities were 47%, 70%, and 88% for FFBC, FNAB, and CB and, for the remaining biopsy sites, 90%, 90%, and 100%, respectively. The combination of FFBC and FNAB showed higher sensitivities than FFBC and FNAB alone. Overall sensitivity for the combination was 88%, with 92%, 72%, and 100% for thorax, liver, and other locations. A definitive diagnosis was made by FFBC in 87% of cases, by FNAB in 74%, and by CB in 88%. The combination of FFBC and FNAB showed a definite diagnosis in 90% of the cases. A tentative diagnosis has been established in 12%, 7%, 5%, and 4%, respectively. In 4 cases (5%), all 3 techniques failed to yield reliable diagnoses. CONCLUSIONS: The examination of FFBCs is a useful supplement to the established technique of CT biopsy. In combination with FNAB, FFBC has a comparable sensitivity as CB in chest punctures and other extrahepatic lesions.


Assuntos
Biópsia por Agulha/métodos , Sangue , Neoplasias/patologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina/métodos , Feminino , Fixadores , Formaldeído , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
5.
Eur J Radiol ; 57(3): 351-5, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16446071

RESUMO

We describe the case of a 72-year-old man presenting with endocarditis and clinical signs of acute myocardial ischemia after biological aortic valve replacement. A comprehensive cardiac dynamic multislice spiral computed tomography demonstrated: (1) an endocarditic vegetation of the aortic valve; (2) a subvalvular leakage feeding a paravalvular pseudoaneurysm based on an aortic root abscess with subsequent compromise of the systolic blood flow in the left main coronary artery and the resulting myocardial perfusion deficit.


Assuntos
Valva Aórtica/diagnóstico por imagem , Bioprótese/microbiologia , Endocardite/diagnóstico por imagem , Próteses Valvulares Cardíacas/microbiologia , Isquemia Miocárdica/diagnóstico por imagem , Infecções Estafilocócicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Endocardite/complicações , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Isquemia Miocárdica/etiologia , Infecções Estafilocócicas/complicações
7.
J Heart Lung Transplant ; 25(1): 90-8, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16399536

RESUMO

BACKGROUND: Previous studies have shown that passive epicardial constraint using a cardiac support device (CSD) reduces left ventricular (LV) size. However, specific data describing LV shape and the time course of changes in LV geometry are still incomplete. Thus, the aim of this study was-using 3-dimensional data sets obtained by computed tomography (CT)-to test the hypothesis that the CSD not only alters LV size but also LV shape, and that short-term post-operative changes in LV geometry are maintained during long-term follow-up. METHODS: Ten patients with non-ischemic dilated cardiomyopathy underwent electron-beam CT examination before and again at 2.6 +/- 0.5 and 32.4 +/- 8.7 months after CSD implantation. At end-diastole and end-systole LV volumes, the length-to-width diameter ratio and a sphericity index were determined and ejection fraction and end-systolic meridional and circumferential wall stress were calculated. RESULTS: Implantation of the CSD led to a significant reduction in LV size, a more ellipsoidal LV shape and a subsequent decrease of LV wall stress post-operatively (p < 0.05 for each), but no substantial changes were found between short- and long-term follow-up (p > 0.05 each). Mean pre-operative and early and late post-operative end-diastolic values were 310.4 +/- 87.8, 235.5 +/- 102.0 and 229.4 +/- 103.1 ml for volume; 1.27 +/- 0.20, 1.37 +/- 0.20 and 1.38 +/- 0.20 for diameter ratio; and 0.78 +/- 0.22, 0.67 +/- 0.26 and 0.65 +/- 0.23 for sphericity index. A similar pattern was observed for end-systolic values. Ejection fraction was 23.4 +/- 6.2%, 32.9 +/- 11.6% and 34.4 +/- 14.9%. End-systolic meridional and circumferential wall stress was 182.2 +/- 45.6, 128.2 +/- 52.6, 130.6 +/- 56.7 kdyn/cm(2) and 411.5 +/- 94.0, 297.4 +/- 108.4 and 302.8 +/- 117.5 kdyn/cm(2), respectively. CONCLUSIONS: Three-dimensional data obtained by CT demonstrate that passive cardiac constraint leads not only to a size reduction but also to an ellipsoidal re-shaping. Our data indicate that these effects are primarily a short-term consequence of the CSD implantation but are maintained during long-term follow-up.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Remodelação Ventricular , Cardiomiopatia Dilatada/diagnóstico por imagem , Estudos de Casos e Controles , Diástole , Insuficiência Cardíaca/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral , Estudos Prospectivos , Estudos Retrospectivos , Sístole , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
8.
Acad Radiol ; 13(1): 95-103, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16399037

RESUMO

RATIONALE AND OBJECTIVES: The aim of the study is to determine whether intravascular time-density course and visualization of the coronary arteries differ with use of a hyperosmolar monomeric versus an iso-osmolar dimeric contrast agent in electron beam tomography (EBT) of the heart. MATERIALS AND METHODS: Fifty-nine patients underwent EBT of the coronary arteries using the monomeric ioversol or the dimeric iodixanol at the same concentration of 320 mg I/mL. Contrast volume was determined relative to body surface area and injected over 40 seconds. Intravascular time-density curves were created for quantitative analysis. For qualitative assessment, visualization of coronary arteries on axial scans and three-dimensional reconstructions was scored. Patients were matched for contrast flow, transit time, and mean pulse rate for statistical analysis. RESULTS: Ioversol produced a significantly greater increase in intravascular density for up to 30 seconds after injection (P < .01) compared with iodixanol. No difference between the two contrast media was seen in the qualitative assessment. CONCLUSION: Monomeric and dimeric contrast media differ in their time-density curves at coronary EBT, a reason for which is not apparent. Qualitative evaluation of coronary arteries is not affected by this difference.


Assuntos
Meios de Contraste/farmacocinética , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Ácidos Tri-Iodobenzoicos/farmacocinética , Área Sob a Curva , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
9.
Eur J Radiol ; 57(3): 356-67, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16427236

RESUMO

Electron beam computed tomography (EBCT) revolutionized cardiac imaging by combining a constant high temporal resolution with prospective ECG triggering. For years, EBCT was the primary technique for some non-invasive diagnostic cardiac procedures such as calcium scoring and non-invasive angiography of the coronary arteries. Multislice spiral computed tomography (MSCT) on the other hand significantly advanced cardiac imaging through high volume coverage, improved spatial resolution and retrospective ECG gating. This pictorial review will illustrate the basic differences between both modalities with special emphasis to their image quality. Several experimental and clinical examples demonstrate the strengths and limitations of both imaging modalities in an intraindividual comparison for a broad range of diagnostic applications such as coronary artery calcium scoring, coronary angiography including stent visualization as well as functional assessment of the cardiac ventricles and valves. In general, our examples indicate that EBCT suffers from a number of shortcomings such as limited spatial resolution and a low contrast-to-noise ratio. Thus, EBCT should now only be used in selected cases where a constant high temporal resolution is a crucial issue, such as dynamic (cine) imaging. Due to isotropic submillimeter spatial resolution and retrospective data selection MSCT seems to be the non-invasive method of choice for cardiac imaging in general, and for assessment of the coronary arteries in particular. However, technical developments are still needed to further improve the temporal resolution in MSCT and to reduce the substantial radiation exposure.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Coração/diagnóstico por imagem , Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X , Animais , Eletrocardiografia , Humanos , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X/métodos
10.
Int J Cardiovasc Imaging ; 22(1): 111-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16374527

RESUMO

OBJECTIVES: We compared the accuracy and reliability of prospectively triggered, retrospectively ECG gated, and non-gated CT image reconstruction for measurements of coronary artery calcification (CAC) in vivo using a novel animal model. MATERIALS AND METHODS: In six Yorkshire farm pigs, prefabricated chains of cortical bone fragments were sutured over the epicardial bed of the major coronary arteries. Using a 4-slice MDCT scanner, each animal was imaged with two different protocols: sequential acquisition with prospective ECG triggering, and spiral acquisition with retrospectively ECG gated image reconstruction- non-gated reconstructions were also generated from these latter scans. Two independent observers measured the 'Agatston score' (AS), the calcified volume (CV), and mineral mass (MM). To calculate accuracy of MM measurements the ash weight of the burned bone fragments was compared to MDCT derived MM. RESULTS: Six pigs successfully underwent surgery and CT imaging (mean heart rate: 86+/-12 bpm). MM measurements from prospectively ECG triggered CT sequential scans were more accurate (p<0.02) and reproducible (p=0.05) than sequential CT scans without ECG triggering or spiral acquisition using retrospective ECG gating. CONCLUSIONS: At high heart rates prospective ECG triggered image reconstruction is more accurate and reproducible for CAC scoring than retrospective ECG gated reconstruction and non-gated reconstruction.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Espiral/métodos , Análise de Variância , Animais , Eletrocardiografia , Estudos de Viabilidade , Reprodutibilidade dos Testes , Suínos
11.
Radiology ; 236(1): 47-55, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15987962

RESUMO

PURPOSE: To prospectively compare mitral valve regurgitation fractions calculated at electron-beam computed tomography (CT) (Doppler echocardiography as reference standard) and to evaluate accuracy of electron-beam CT volume and flow measurements compared with magnetic resonance (MR) imaging results. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Volume and flow measurements were performed at electron-beam CT in 219 patients (197 men, 22 women; mean age, 61.5 years +/- 10.4 [standard deviation]), of whom 157 had known isolated mitral valve regurgitation. Regurgitation volume was calculated as the difference between left ventricular total and forward stroke volumes. Regurgitation fractions were compared with corresponding echocardiographic grades (grades 0-IV) by using Spearman rank correlation and a weighted kappa test. In 22 patients, CT volume and flow measurements were compared with MR results by using intraclass correlation. RESULTS: Regurgitation fractions at CT correlated well with echocardiographic grading (rank correlation coefficient, r(S) = 0.82; P < .05). Mean regurgitation fractions for echocardiographic grades 0, I, II, III, and IV were 3.1% +/- 6.2, 12.7% +/- 9.9, 25.3% +/- 12.3, 40.4% +/- 11.5, and 55.9% +/- 13.7, respectively. The most suitable thresholds for differentiating echocardiographic grades were calculated regurgitation fractions of 6%, 20%, 30%, and 44%; with these thresholds, individual echocardiographic grades were differentiated (grades 0 vs I-IV, 0-I vs II-IV, 0-II vs III-IV, and 0-III vs IV, respectively) with sensitivities of 89%, 87%, 86%, and 93% and specificities of 81%, 87%, 92%, and 91%, respectively. There was perfect agreement in classification of mitral valve insufficiency between electron-beam CT and echocardiography in 134 (61%) patients and a mismatch by one grade in 72 (33%) and by two grades in 13 (6%) (kappa = 0.84). Intraclass correlation coefficients between CT and MR imaging for total and forward stroke volumes and regurgitation volume and fraction were 0.88, 0.79, 0.93, and 0.89, respectively. CONCLUSION: Electron-beam CT provides quantitative information on severity of mitral valve regurgitation, but semiquantitative classification of regurgitation showed mismatch between electron-beam CT and Doppler echocardiography by at least one grade in more than one-third of all patients.


Assuntos
Ecocardiografia Doppler , Insuficiência da Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Estatísticas não Paramétricas , Volume Sistólico
12.
Invest Radiol ; 39(12): 728-39, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15550834

RESUMO

OBJECTIVES: We sought to determine the agreement between electron-beam computed tomography (CT) and cardiac catheterization for the quantification of mitral regurgitation and to evaluate their association with echocardiographic assessment. MATERIAL AND METHODS: Fifty patients with congestive heart failure were examined both by electron-beam CT and catheterization to calculate mitral regurgitation volume and fraction based on the difference between the left ventricular stroke and aortic flow volume. The severity of regurgitation was also compared with visual assessment by echocardiography (grade, 0-4+). RESULTS: The mean values for the mitral regurgitation volume and fraction did not differ significantly between electron-beam CT and catheterization (mean differences: 0.2 mL/m2 and -0.9%, P > 0.05 each, limits of agreement: -14.0 to 14.4 mL/m2 and -26.3 to 24.5%, respectively) and showed a good correlation (r = 0.79 and r = 0.76, respectively; P < 0.05 each). Good levels of correlation were observed between echocardiographic severity grading and quantitative measurements of regurgitation volume and fraction, which were somewhat better between echocardiography and electron-beam CT (rS = 0.78 and rS = 0.84, respectively; P < 0.05 each) than between echocardiography and catheterization (rS = 0.72 and rS = 0.81, respectively; P < 0.05 each). CONCLUSION: Our results suggest that electron-beam CT allows for quantification of mitral valve regurgitation with similar accuracy as cardiac catheterization. Measurements with both modalities correlated well with the results of echocardiographic assessment.


Assuntos
Cateterismo Cardíaco , Insuficiência Cardíaca/complicações , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Índice de Gravidade de Doença
13.
J Comput Assist Tomogr ; 28(5): 679-85, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15480045

RESUMO

OBJECTIVE: Intraindividual comparison of right ventricular volumes and function using electron beam computed tomography (EBT) and magnetic resonance imaging (MRI). METHODS: Twenty-seven patients with a known cardiac history were referred for evaluation of ventricular function parameters. The following standardized protocols were used: contrast-enhanced multislice mode EBT and gradient echo sequence MRI. Right ventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were calculated using a slice summation method. Interobserver variability was calculated. RESULTS: The correlation between the 2 methods was: r = 0.901 for EDV, r = 0.938 for ESV, r = 0.823 for SV, and r = 0.953 for EF. Electron beam computed tomography overestimated EDV and ESV slightly when compared with MRI (P < 0.05). No significant differences (P > 0.05) were found between SV and EF. Mean values determined by EBT and MRI were as follows: 168.6 +/- 62.3 mL and 153.7 +/- 59.1 mL for EDV, 104.7 +/- 60.4 mL and 95.1 +/- 54.8 mL for ESV, 63.2 +/- 19.3 mL and 58.7 +/- 19.8 mL for SV, and 40.2% +/- 14.1% and 40.2% +/- 13.6% for EF, respectively. Interobserver variability ranged between 1.0% and 3.2%. CONCLUSION: Electron beam computed tomography shows good agreement with a close correlation and an acceptable interobserver variability for right ventricular volumes and global function, with a small but significant overestimation of EDV and ESV when compared with MRI.


Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Disfunção Ventricular Direita/diagnóstico , Adulto , Idoso , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Volume Sistólico , Fatores de Tempo , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita
14.
Ann Thorac Surg ; 78(3): 900-5, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15337017

RESUMO

BACKGROUND: Previous studies have shown that the cardiac support device (CSD) improves left ventricular structure and function in patients with heart failure by preventing further cardiac enlargement. The aim of this study was to identify effects on the right ventricle (RV). METHODS: Ten male patients with idiopathic dilated cardiomyopathy underwent electron-beam computed tomographic (CT) examination within 1 month before, and 6 to 9 months after CSD implantation. The RV end-diastolic and end-systolic volumes (EDV, ESV) and diameters (EDD, ESD), stroke volume (SV), ejection fraction (EF), total and forward RV output (RVO, fRVO), and tricuspid regurgitation fraction (TRF) were calculated. RESULTS: The EDV measurements decreased from 182.1 +/- 49.6 to 137.5 +/- 37.0 mL, ESV from 114.8 +/- 47.0 to 68.3 +/- 23.8 mL, EDD from 48.2 +/- 6.6 to 41.6 +/- 7.1 mm, and ESD from 39.6 +/- 6.9 to 32.7 +/- 6.5 mm (p < 0.05 for each). Ejection fraction increased from 38.5 +/- 8.9 to 52.0% +/- 7.7% and fRVO from 4.0 +/- 0.8 to 4.6 +/- 1.1 L/min (each with p < 0.05). TRF decreased from 18.2 +/- 14.1 to 10.4% +/- 13.5%, whereas SV and RVO remained nearly unchanged. Postoperatively, RV volumes, EF, and fRVO were not different from 15 age- and gender-matched normal control patients. CONCLUSIONS: Implantation of a CSD leads to a decrease in RV size and improved RV performance. These data together with the results of previous studies demonstrating improved left ventricular structure and function confirm the biventricular nature of recovery with the CSD.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Coração Auxiliar , Cardiomiopatia Dilatada/fisiopatologia , Diástole , Ecocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Função Ventricular Direita
15.
Invest Radiol ; 39(6): 357-64, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15167102

RESUMO

OBJECTIVE: Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-beam CT (EBCT). MATERIALS AND METHODS: Six minipigs underwent MSCT (collimation 4 x 1 mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. RESULTS: MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). CONCLUSIONS: Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.


Assuntos
Angiografia Coronária/métodos , Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X , Animais , Artefatos , Individualidade , Doses de Radiação , Suínos , Porco Miniatura
16.
J Heart Lung Transplant ; 23(1): 11-9, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14734122

RESUMO

BACKGROUND: The cardiac support device (CSD, Acorn) is a compliant, textile-mesh graft placed around the ventricles to prevent further dilatation and to improve function in congestive heart failure. The aim of this study was to verify post-operative changes in left ventricular volumes, ejection fraction, blood flow, and myocardial mass. METHODS: Fourteen patients underwent contrast-enhanced, electrocardiography-triggered electron-beam computerized tomography before and 6 to 9 months after CSD implantation. We measured volume and flow using the slice-summation method and the indicator-dilution technique. RESULTS: We found significant changes for the following parameters: end-diastolic volume decreased from 382.9 +/- 140.2 ml to 311.3 +/- 138.7 ml, end-systolic volume from 310.4 +/- 132.4 ml to 237.4 +/- 133.8 ml, end-diastolic diameter from 75.3 +/- 7.8 mm to 70.7 +/- 11.6 mm, end-systolic diameter from 65.8 +/- 7.8 mm to 60.0 +/- 14.0 mm, and myocardial mass from 298.6 +/- 79.6 g to 263.1 +/- 76.8 g. Ejection fraction increased from 20.3% +/- 6.4% to 27.8% +/- 13.1%. We found no significant differences for stroke volume (from 72.5 +/- 24.6 ml to 73.8 +/- 23.6 ml), heart rate (from 80.5 +/- 11.0 beats per minute to 76.5 +/- 6.8 beats per minute), and total cardiac output (from 5.8 +/- 1.9 liter/min to 5.6 +/- 1.8 liter/min). Mitral regurgitation fraction decreased from 30.5% +/- 15.5% to 15.6% +/- 12.8%, increasing antegrade cardiac output from 3.8 +/- 0.9 liter/min to 4.7+/-1.5 liter/min. For most parameters, pre- and post-operative values in these patients differed significantly from those in an age- and gender-matched control group. In each patient, we observed a small hyperdense stripe along the pericardium after surgery, but we observed no local complications. CONCLUSION: Three-dimensional structural and functional data obtained by computerized tomography volume and flow measurements confirm the safety and efficacy of CSD implantation.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Telas Cirúrgicas , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Débito Cardíaco , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese , Implantação de Prótese , Volume Sistólico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Eur J Cardiothorac Surg ; 25(1): 84-90, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14690737

RESUMO

OBJECTIVE: To verify changes in left ventricular (LV) volumes and regional myocardial wall motion after implantation of a textile cardiac support device (CSD) for passive external constraint in non-ischemic dilated cardiomyopathy. METHODS: In nine male patients participating in a non-randomized clinical trial LV volumes were determined and the segmental LV wall motion was studied by contrast-enhanced electron-beam CT in a sectionwise manner at three ventricular levels (base, middle and apex of ventricle) before and 32+/-6 months after CSD implantation. In 16 myocardial segments ejection fraction and wall thickening were measured semiautomatically after drawing the myocardial contours. The wall motion score index was calculated based on semiquantitative visual grading in each segment. RESULTS: The global LV volumes decreased significantly from 304.3 +/- 90.9 to 231.5 +/- 103.9 ml at end-diastole and from 239.7 +/- 83.7 to 164.0 +/- 97.7 at end-systole (P<0.05). Overall ejection fraction increased from 14.8 +/- 8.2 to 25.7 +/- 17.1% (P<0.05). A segment-by-segment analysis demonstrated a significant increase of regional ejection fraction in the basal myocardium as well as in the mid-inferior, mid-inferolateral, and mid-anterolateral myocardium. Overall wall thickening increased from 16.4 +/- 13.3 to 24.2 +/- 18.1% (P<0.05), but without significant differences in a segment-by-segment comparison. The mean wall motion score index improved from 2.70 +/- 0.26 to 2.20 +/- 0.71 (P<0.05), with an increased wall motion in eight (89%) patients. A section-by-section analysis demonstrated significantly improved wall motion in the inferior and lateral segments at each ventricular level. Postoperatively, the number of akinetic and markedly hypokinetic segments decreased significantly (P<0.05) from 56 (39%) to 26 (18%) and from 76 (53%) to 56 (37%), respectively. CONCLUSION: CSD implantation improves segmental wall motion, predominantly in the inferior and lateral myocardium, and reduces the number of akinetic and hypokinetic segments.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Telas Cirúrgicas , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Materiais Biocompatíveis , Cardiomiopatia Dilatada/fisiopatologia , Desenho de Equipamento , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Tomografia Computadorizada por Raios X/métodos
19.
J Comput Assist Tomogr ; 27(3): 385-91, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12794604

RESUMO

PURPOSE: This study was designed to evaluate electron beam computed tomography (CT) for quantifying mitral regurgitation in comparison with magnetic resonance (MR) imaging as a reference method. METHOD: Forty-three patients, among them 33 with known mitral regurgitation, underwent electron beam CT and MR imaging. Total left ventricular stroke volume (TSV), antegrade stroke volume (ASV), and mitral regurgitation volume (MRV) and fraction (MRF) were determined and compared between the two modalities. Additionally electron beam CT measurements were compared with the corresponding echocardiographic findings. RESULTS: Significant differences between electron beam CT and MR imaging were found for measurements of TSV and MSV but not for ASV and MRF. There was a close linear correlation between both modalities for all parameters. Furthermore, there was good agreement between electron beam CT and echocardiography, although electron beam CT shows a tendency to overestimate mitral regurgitation slightly. CONCLUSION: The results indicate that electron beam CT offers an additional procedure for quantifying mitral regurgitation and that it may be used as an alternative to MR imaging.


Assuntos
Insuficiência da Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda/fisiologia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Modelos Lineares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico , Volume Sistólico/fisiologia
20.
Eur Radiol ; 13(6): 1394-401, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12764657

RESUMO

Our objective was to determine if left ventricular reduction surgery affects left and right ventricular volumes and function. Twenty-three patients with end-stage heart failure underwent contrast-enhanced electron beam tomographic function studies before and twice after partial left ventriculectomy (PLV). The PLV was combined with other cardiosurgical procedures in 20 of 23 patients. Left and right ventricular enddiastolic volume (LVEDV, RVEDV), stroke volume (LVSV, RVSV), ejection fraction (LVEF, RVEF), and enddiastolic diameter (LVEDD, RVEDD) were determined by manual tracing of endo- and epicardial borders at enddiastole and endsystole. Patients were scanned 31 days (+/-34) before and 18 days (+/-13) and 8 months (+/-4) after PLV. Mean pre- and early and late postoperative values for LVEDV, LVSV, LVEF, and LVEDD were 387.9 ml (+/-125.5 ml), 255.6 ml (+/-79.3 ml; p<0.01), and 253.7 ml (+/-97.8 ml; p<0.05), 79.7 ml (+/-25.2 ml), 74.8 ml (+/-17.9; n.s.), and 79.1 ml (+/-26.5 ml; n.s.), 21.6% (+/-7.3%), 31.9% (+/-13.4%; p<0.05), and 34.1% (+/-14.1%; p<0.05), and 72.0 mm (+/-10.6 mm), 64.3 mm (+/-8.5 mm; p<0.05), and 63.5 mm (+/-9.4 mm; p<0.05), respectively. Mean pre- and postoperative values for RVEDV, RVSV, RVEF, and RVEDD were 177.7 ml (+/-72.8 ml), 172.4 ml (+/-59.2 ml; n.s.), and 178.9 ml (+/-60.8 ml; n.s.), 60.3 ml (+/-21.6 ml), 68.8 ml (+/-19.9 ml; n.s.), and 78.3 ml (+/-25.3 ml; n.s.), 38.1% (+/-15.4%), 43.7% (+/-16.3%; p<0.05), and 45.1% (+/-11.2%; n.s.), and 50.4 mm (+/-10.9 mm), 48.1 mm (+/-8.7 mm; n.s.), and 48.5 mm (+/-9.8 mm; n.s.), respectively. The PLV may induce a significant early reduction of left ventricular volumes and improvement of biventricular function; however, our results must be judged carefully as the majority of patients in this study underwent additional cardiosurgical procedures, the contributory effect of which on the overall outcome remains unclear.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Feminino , Coração/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Período Pós-Operatório , Cuidados Pré-Operatórios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...