Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Intractable Rare Dis Res ; 13(1): 23-28, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38404738

RESUMO

Situs viscerum inversus (SVI) is a very rare condition in that abdominal and thoracic organs are located reversed. Abdominal aortic aneurysm (AAA) is a life-threatening pathology due to progressive aortic enlargement until the rupture. The association between SVI and AAA is very infrequent. The aim of this study is to identify the surgical procedures available to treat AAA in SVI. We performed a literature review of all studies about AAA in SVI patients, analyzing PubMed/MEDLINE, EMBASE, Web of Science (WOS), Google Scholar databases. The survey includes all publications until June 2023. The outcomes include demographic findings, type of surgical procedure, intraoperative and postoperative complications, follow-up. A total of 12 studies, including 12 patients, were considered eligible for the review. AAA mean size was 70.5 mm (range: 55-90 mm); the most common localization was in the infrarenal aortic portion. 6 studies reported data on elective surgery, and 6 on emergency procedures. In one case endovascular treatment was performed. No intraoperative complications are reported; 3 postoperative complications are registered. Medium follow-up period was 13.5 months (range: 3-60). According to the available literature, the treatment of AAA in SVI is feasible and does not show an incremented morbidity compared to patients with a normal visceral configuration. This treatment seems to be effective also in case of endovascular treatment. AAA treatment in SVI should be performed (especially in elective settings) in high volume centers where it is possible to bring on collaboration across different surgical specialists.

2.
Healthcare (Basel) ; 10(5)2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35628036

RESUMO

When planning an operation, surgeons usually rely on traditional 2D imaging. Moreover, colon neoplastic lesions are not always easy to locate macroscopically, even during surgery. A 3D virtual model may allow surgeons to localize lesions with more precision and to better visualize the anatomy. In this study, we primary analyzed and discussed the clinical impact of using such 3D models in colorectal surgery. This is a monocentric prospective observational pilot study that includes 14 consecutive patients who presented colorectal lesions with indication for surgical therapy. A staging computed tomography (CT)/magnetic resonance imaging (MRI) scan and a colonoscopy were performed on each patient. The information gained from them was provided to obtain a 3D rendering. The 2D images were shown to the surgeon performing the operation, while the 3D reconstructions were shown to a second surgeon. Both of them had to locate the lesion and describe which procedure they would have performed; we then compared their answers with one another and with the intraoperative and histopathological findings. The lesion localizations based on the 3D models were accurate in 100% of cases, in contrast to conventional 2D CT scans, which could not detect the lesion in two patients (in these cases, lesion localization was based on colonoscopy). The 3D model reconstruction allowed an excellent concordance correlation between the estimated and the actual location of the lesion, allowing the surgeon to correctly plan the procedure with excellent results. Larger clinical studies are certainly required.

3.
In Vivo ; 35(2): 1299-1305, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33622934

RESUMO

BACKGROUND/AIM: A notable re-allocation of healthcare resources and specific clinical and organizational measures have been required to prevent COVID-19 infection among hospitalized patients and healthcare workers. PATIENTS AND METHODS: From March 9th to May 9th 2020 we performed colorectal cancer elective surgery on 25 patients: a pre-hospital screening was carried out in order to avoid hospitalization of patients suspected of COVID-19 infection. RESULTS: All patients (median age=76 years; range=37-88 years) were considered suitable for admission after telephone triage; the median interval between primary diagnosis and hospital admission was 23.1 days (range=1-55 days). The median hospitalization was 7.8 days (range=4-18 days). One COVID-19-associated death was reported. CONCLUSION: Our experience demonstrates that safe colorectal cancer elective surgery can be performed during the pandemic COVID-19. Further consensus and guidelines to prevent diffusion of pandemic diseases among hospitalized patients and healthcare workers still need to be implemented.


Assuntos
COVID-19/prevenção & controle , Neoplasias Colorretais/cirurgia , Procedimentos Cirúrgicos Eletivos/métodos , SARS-CoV-2/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , COVID-19/virologia , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Oncologia/métodos , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2/fisiologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-31906532

RESUMO

Several studies have demonstrated that training with a laparoscopic simulator improves laparoscopic technical skills. We describe how to build a homemade, low-cost laparoscopic training simulator (LABOT) and its validation as a training instrument. First, sixty surgeons filled out a survey characterized by 12 closed-answer questions about realism, ergonomics, and usefulness for surgical training (global scores ranged from 1-very insufficient to 5-very good). The results of the questionnaires showed a mean (±SD) rating score of 4.18 ± 0.65 for all users. Then, 15 students (group S) and 15 residents (group R) completed 3 different tasks (T1, T2, T3), which were repeated twice to evaluate the execution time and the number of users' procedural errors. For T1, the R group had a lower mean execution time and a lower rate of procedural errors than the S group; for T2, the R and S groups had a similar mean execution time, but the R group had a lower rate of errors; and for T3, the R and S groups had a similar mean execution time and rate of errors. On a second attempt, all the participants tended to improve their results in doing these surgical tasks; nevertheless, after subgroup analysis of the T1 results, the S group had a better improvement of both parameters. Our laparoscopic simulator is simple to build, low-cost, easy to use, and seems to be a suitable resource for improving laparoscopic skills. In the future, further studies should evaluate the potential of this laparoscopic box on long-term surgical training with more complex tasks and simulation attempts.


Assuntos
Competência Clínica , Simulação por Computador , Laparoscópios , Laparoscopia , Cirurgiões , Adulto , Instrução por Computador , Custos e Análise de Custo , Educação Médica , Feminino , Humanos , Internato e Residência , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...