Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Dentomaxillofac Radiol ; 36(3): 130-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17463096

RESUMO

OBJECTIVES: The purpose of this study was to develop an alternative diagnostic tool for the early detection of external apical root resorption (EARR). METHODS: Mandibular incisors (n=36) with and without simulated EARR lesions were used. 18 teeth with facial and proximal windows, each with a range of 2 sizes, were placed in 6 N hydrochloric acid (HCl) baths for 10 min. A sample of the acid solution was analysed for calcium concentration by atomic absorption spectrophotometry. Incisors were imaged at 80 degrees, 90 degrees and 100 degrees under 3 test conditions (bracketed, non-bracketed and with subtraction registration templates (SRTs)). The images were reconstructed and subtracted to determine the accuracy and sensitivity of the method. Quantified histograms for each subtracted image were constructed. RESULTS: At either an angle of 80 degrees or 100 degrees, the bracketed group had the largest mean standard deviation of the subtraction histograms while the SRT group had the smallest. Density values as a function of total calcium removed were plotted indicating a linear relationship between subtraction density units and calcium loss. CONCLUSION: The use of the SRTs was significantly more accurate than the use of the brackets alone for digital subtraction radiography reconstructions. This model shows promise for detecting EARR prior to a noticeable decrease in root length. It may be useful for early detection of resorptive lesions during routine orthodontic treatment.


Assuntos
Absorciometria de Fóton/métodos , Radiografia Dentária Digital/métodos , Reabsorção da Raiz/diagnóstico por imagem , Técnica de Subtração , Análise de Variância , Densidade Óssea , Cálcio/análise , Humanos , Incisivo , Modelos Lineares , Reabsorção da Raiz/etiologia , Espectrofotometria Atômica , Ápice Dentário/diagnóstico por imagem , Técnicas de Movimentação Dentária/efeitos adversos
2.
Artigo em Inglês | MEDLINE | ID: mdl-10225638

RESUMO

OBJECTIVE: Automatic exposure control has been used successfully in medicine to improve image quality and reduce the number of retakes necessitated by inadequate operator selection of exposure factors. The purpose of this study was to assess the influence of automatic exposure control on panoramic image quality. STUDY DESIGN: A total of 352 patients were imaged with either the OP 100 or the Orthophos Plus panoramic machine. An expert consensus panel judged film quality using a 5-point scale. Differences in quality that would have resulted from the use of operator-determined exposures were calculated through use of an algorithm validated with test images of a human phantom. RESULTS: McNemar's test demonstrated significant improvements in quality with automatic exposure control (P = .001) in comparison with manual exposure control. No quality difference was found between the 2 machines (P = .9661). Manual exposure selection by oral and maxillofacial radiology residents was better than selection by technologists and assistants (P = .006). CONCLUSIONS: This study confirms the utility of automatic exposure control for panoramic radiography.


Assuntos
Radiografia Panorâmica/instrumentação , Adulto , Algoritmos , Diagnóstico por Computador , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Imagens de Fantasmas , Competência Profissional , Garantia da Qualidade dos Cuidados de Saúde , Doses de Radiação , Radiografia Panorâmica/métodos , Radiografia Panorâmica/normas , Estatísticas não Paramétricas , Tecnologia Radiológica/normas , Filme para Raios X
3.
Dentomaxillofac Radiol ; 27(1): 51-7, 1998 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9482025

RESUMO

OBJECTIVE: To investigate empirically the imaging characteristics of the Orthopantomograph OP 100 and compare them to the average form of the dental arch. METHODS: Repeatable radiographs were taken of a lead resolution grid positioned at 1 mm increments along known angular intervals of the projected X-ray beam. Focal trough thickness was determined by visibility of the 1.5 lp mm-1 resolution limits. The path of the effective rotation center was determined using a film positioned at right angles to the slit beam. The vertical magnification and horizontal magnification and distortion index, corrected for the position of the tomographic layer, were calculated using a reference object placed at various resolution limits of the focal trough. The beam projection angle was calculated with respect to the central plane of the focal trough and the average dental arch shape compared with the average proximal contact angle. RESULTS: The maximum resolution observed at the central plane of the focal trough was 5 lp mm-1. The width of the focal trough varied from 17 mm in the anterior region to 44 mm in the posterior region. The path of the effective rotation center was found to translate between three fixed centers of rotation, with the effective anterior projection radius of 24 mm. The vertical magnification factor within the focal trough showed a linear increase along the beam path from 1.24-1.37 and the horizontal magnification varied from 1.01-1.63. The distortion index varied from 0.84-1.24. The beam projection angle increased from 90 degrees anteriorly to 115 degrees in the premolar area with respect to the central plane of the focal trough and from 90 degrees anteriorly to 110 degrees in the premolar area compared with the average dental arch. CONCLUSIONS: The OP 100 provides a focal trough conforming well to the overall geometry of the dental arch and provides adequate spatial resolution.


Assuntos
Radiografia Panorâmica/instrumentação , Arco Dental/diagnóstico por imagem , Estudos de Avaliação como Assunto , Humanos , Ampliação Radiográfica/instrumentação , Ampliação Radiográfica/métodos , Ampliação Radiográfica/estatística & dados numéricos , Radiografia Panorâmica/métodos , Radiografia Panorâmica/estatística & dados numéricos , Rotação , Ecrans Intensificadores para Raios X/estatística & dados numéricos
4.
Dentomaxillofac Radiol ; 25(5): 302-6, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9161187

RESUMO

OBJECTIVES: To determine the modulation transfer function (MTF) and noise equivalent passband (NE) values for a newly revised rotational panoramic X-ray machine, the PC-1000 (Panoramic Corp., Fort Wayne, Indiana, USA). METHODS: Images of a 10 microns test slit were taken at various locations along the X-ray beam projection path using a Lanex Regular/T-Mat G image receptor. Line spread functions were obtained at specific beam paths by scanning slit images with a microdensitometer. RESULTS: MTF values were highest around the central plane of the image layer, with a maximum near the centre of 0.25 at 4 cycles/mm. The NE values near the central plane of image layer were 1.4 cycles/mm. MTF and NE values in the anterior region were low, 0.2 and 1.2, respectively. The width of the image layer was narrower in the anterior and wider in the posterior segments. Rapid decreases in MTF and NE values were found on the X-ray tube side compared with the receptor side of the central plane. Using a spatial frequency of 0.25 MTF the shape of the image layer was coincident with that determined visually. CONCLUSION: On the basis of the MTF and NE values the image resolution produced by this machine is considered acceptable for panoramic dental radiography.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia Panorâmica/instrumentação , Matemática
5.
Quintessence Int ; 27(3): 175-8, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9063230

RESUMO

The performance of a low-cost teleradiology system was studied. The time needed for radiographic transmission between computers and the image integrity following transmission were measured. The image resolution was analyzed with a line-pair test chart. Images were transmitted through computers that had a video-processing board and a modem at both the transmission and receiving sites. Intraoral radiographs were captured with a black and white charge-coupled device camera. The time required for image transmission was less than 1 minute (46 to 56 seconds), an effective transmission speed of 1.73 kbyte/s (13.9 kbit/s). No changes were observed in pixel value distributions; hence, there was no loss of image detail. The maximal resolution of the system was 4 line-pairs/mm. The performance of the teleradiology system demonstrated its potential as an effective, low-cost telenetwork for dentistry.


Assuntos
Radiografia Dentária/métodos , Telerradiologia/métodos , Diagnóstico por Computador , Humanos , Processamento de Imagem Assistida por Computador , Garantia da Qualidade dos Cuidados de Saúde , Radiografia Dentária/economia , Telerradiologia/economia
6.
J Telemed Telecare ; 2(4): 217-23, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9375062

RESUMO

Tomograms of the temporomandibular joint were digitized in three different formats using a PC-based system. The image resolution for various projections was determined at different camera-film distances. Three series of images were transmitted by telephone, and transmission times were measured. The original radiographs, the digitized images, the transmitted images and the transmitted-and-printed images were presented to 10 observers, who were asked to rate image quality. No difference in image quality was found between the initial digitized and the transmitted images. However, transmitted and transmitted-and-printed images were of significantly lower quality than the original radiographs or the digitized images viewed on a computer monitor. Transmission time was reduced significantly (50%) by cropping the images before transmission. The image quality of individual radiographs was better than radiographs formatted as a series.


Assuntos
Odontologia , Telerradiologia , Articulação Temporomandibular/diagnóstico por imagem , Tomografia por Raios X/instrumentação , Conversão Análogo-Digital , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA