Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-19963926

RESUMO

This paper presents the design, mathematical model, fabrication and testing of a novel type of in-vivo stiffness sensor. The proposed sensor can measure both tissue stiffness and contact force. The sensing concept utilizes multiple membranes with varying stiffness and is particularly designed for integration with minimally invasive surgical (MIS) tools. In order to validate the new sensing concept, MEMS capacitive sensors are fabricated using surface micromachining with each fabricated sensor having a 1mm x 1mm active sensor area. Finally, the sensors are tested by touching polymers of different elastic stiffnesses. The results are promising and confirm the capability of the sensor for measuring both force and tissue compliance.


Assuntos
Técnicas Biossensoriais/instrumentação , Sistemas Microeletromecânicos/instrumentação , Fenômenos Biomecânicos , Módulo de Elasticidade , Capacitância Elétrica , Desenho de Equipamento , Membranas Artificiais , Especificidade de Órgãos , Polímeros
2.
J Biomech Eng ; 127(6): 1035-40, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16438246

RESUMO

The recording of neural ensembles in awake, behaving rats has been an extremely successful experimental paradigm, providing demonstrable scientific advances. Dynamic control of the position of the implanted electrodes is of key importance as mobile electrodes provide a better signal-to-noise ratio and a better cell/ electrode yield than nonmobile electrodes. Here we describe the use of low cost, soon to be commercially available dc motors to successfully control the depth of electrodes. The prototype designed is approximately 30 mm in diameter and 50 mm in length and weighed about 30 gms. This paper presents the results of linear displacements of electrodes achievable with this motorized microdrive.


Assuntos
Potenciais de Ação/fisiologia , Comportamento Animal/fisiologia , Eletrodos Implantados , Microeletrodos , Micromanipulação/instrumentação , Rede Nervosa/fisiologia , Células Piramidais/fisiologia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Masculino , Micromanipulação/métodos , Miniaturização , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Movimento (Física) , Ratos , Ratos Endogâmicos F344 , Vigília
3.
Proc Inst Mech Eng H ; 218(2): 89-100, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15116896

RESUMO

Various uses of the screw or helical axis have previously been reported in the literature in an attempt to quantify the complex displacements and coupled rotations of in vivo human knee kinematics. Multiple methods have been used by previous authors to calculate the axis parameters, and it has been theorized that the mathematical stability and accuracy of the finite helical axis (FHA) is highly dependent on experimental variability and rotation increment spacing between axis calculations. Previous research has not addressed the sensitivity of the FHA for true in vivo data collection, as required for gait laboratory analysis. This research presents a controlled series of experiments simulating continuous data collection as utilized in gait analysis to investigate the sensitivity of the three-dimensional finite screw axis parameters of rotation, displacement, orientation and location with regard to time step increment spacing, utilizing two different methods for spatial location. Six-degree-of-freedom motion parameters are measured for an idealized rigid body knee model that is constrained to a planar motion profile for the purposes of error analysis. The kinematic data are collected using a multicamera optoelectronic system combined with an error minimization algorithm known as the point cluster method. Rotation about the screw axis is seen to be repeatable, accurate and time step increment insensitive. Displacement along the axis is highly dependent on time step increment sizing, with smaller rotation angles between calculations producing more accuracy. Orientation of the axis in space is accurate with only a slight filtering effect noticed during motion reversal. Locating the screw axis by a projected point onto the screw axis from the mid-point of the finite displacement is found to be less sensitive to motion reversal than finding the intersection of the axis with a reference plane. A filtering effect of the spatial location parameters was noted for larger time step increments during periods of little or no rotation.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Articulação do Joelho/fisiologia , Modelos Biológicos , Movimento/fisiologia , Fotogrametria/métodos , Amplitude de Movimento Articular/fisiologia , Simulação por Computador , Interpretação Estatística de Dados , Análise de Elementos Finitos , Humanos , Movimento (Física) , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade
4.
J Med Eng Technol ; 27(5): 207-17, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12936047

RESUMO

There is an ongoing need for therapeutic cervical traction to treat chronic idiopathic neck pain. A device was designed to perform low-load cervical traction (unloading) with the patient in an upright, seated, neutral spine position. A prototype device meeting these requirements was constructed. During subsequent use, several methods for assessing the outcome of such unloading were proposed, including radiographic images, cervical range-of-motion measurements and muscle EMG activity. The prototype and measurement methods were tested on a population of normal subjects. The results demonstrated that the device design is safe and effectively transfers load into the occipital region of the skull. The use of low-load cervical unloading induced lateral rotation and posterior lengthening of the spine. Device refinements were identified. The results demonstrated that the methods described may be safely employed on a patient population.


Assuntos
Vértebras Cervicais/fisiologia , Análise de Falha de Equipamento/métodos , Imobilização , Músculo Esquelético/fisiologia , Cervicalgia/reabilitação , Postura/fisiologia , Tração/instrumentação , Suporte de Carga/fisiologia , Temperatura Corporal , Vértebras Cervicais/diagnóstico por imagem , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Contração Muscular/fisiologia , Projetos Piloto , Radiografia , Amplitude de Movimento Articular , Valores de Referência , Tração/métodos
5.
Annu Rev Biomed Eng ; 2: 551-76, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11701523

RESUMO

The application of microelectromechanical systems (MEMS) to medicine is described. Three types of biomedical devices are considered, including diagnostic microsystems, surgical microsystems, and therapeutic microsystems. The opportunities of MEMS miniaturization in these emerging disciplines are considered, with emphasis placed on the importance of the technology in providing a better outcome for the patient and a lower overall health care cost. Several case examples in each of these areas are described. Key aspects of MEMS technology as it is applied to these three areas are described, along with some of the fabrication challenges.


Assuntos
Micromanipulação/instrumentação , Engenharia Biomédica , Técnicas Biossensoriais , Sistemas de Liberação de Medicamentos/instrumentação , Implantes de Medicamento , Humanos , Espectrometria de Massas/instrumentação , Microcirurgia/instrumentação , Instrumentos Cirúrgicos
6.
J Biomech Eng ; 114(1): 101-10, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1491572

RESUMO

The six-revolute-joint instrumented spatial linkage (6R ISL) is often the measurement system of choice for monitoring motion of anatomical joints. However, due to tolerances of the linkage parameters, the system may not be as accurate as desired. A calibration algorithm and associated calibration device have been developed to refine the initial measurements of the ISL's mechanical and electrical parameters so that the measurement of six-degree-of-freedom motion will be most accurate within the workspace of the anatomical joint. The algorithm adjusts the magnitudes of selected linkage parameters to reduce the squared differences between the six known and calculated anatomical position parameters at all the calibration positions. Weighting is permitted so as to obtain a linkage parameter set that is specialized for measuring certain anatomical position parameters. Output of the algorithm includes estimates of the measuring system accuracy. For a particular knee-motion-measuring ISL and calibration device, several interdependent design parameter relationships have been identified. These interdependent relationships are due to the configuration of the ISL and calibration device, the number of calibration positions, and the limited resolution of the devices that monitor the position of the linkage joints. It is shown that if interdependence is not eliminated, then the resulting ISL parameter set will not be accurate in measuring motion outside of the calibration positions, even though these positions are within the ISL workspace.


Assuntos
Calibragem , Desenho de Equipamento/normas , Articulações/fisiologia , Amplitude de Movimento Articular , Algoritmos , Humanos , Articulações/anatomia & histologia , Reprodutibilidade dos Testes , Rotação
7.
J Biomech Eng ; 114(1): 92-100, 1992 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1491592

RESUMO

Six-revolute-joint instrumented spatial linkages (6R ISLs) have become often-used devices to measure the complete six-degree-of-freedom motion of anatomical joints. Accuracy of motion measurement depends on ISL design and calibration technique. In this paper, a design process is outlined that uses computer graphics and numerical methods as aids in developing 6R ISLs that (i) physically assemble within the desired range of motion of the joint; (ii) do not collide with either the experimental apparatus or the subject joint; (iii) avoid singular linkage configurations that can cause forces to be applied to the joint; and (iv) measure selected anatomical motions most accurately. It is found that a certain subgroup of 6R linkages are suitable for accurate measurement of specific motions, and can be the basis for new ISL designs. General guidelines are developed that can assist in the generation of unique linkage designs for different anatomical joints. The design process is demonstrated in the creation of an ISL to measure knee motion.


Assuntos
Desenho de Equipamento/normas , Articulações/fisiologia , Amplitude de Movimento Articular , Simulação por Computador , Humanos , Articulações/anatomia & histologia , Modelos Anatômicos
8.
IEEE Trans Biomed Eng ; 38(4): 314-8, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1855790

RESUMO

Computer-aided design and manufacturing for dental restorations has opened a new world of possibilities--some that appeal to engineers and clinicians and some that have created some interesting challenges. The objective of this overview is to briefly describe a system being developed by the Universities of Maryland and Minnesota which is capable of producing dental crowns. Some of the challenges and difficulties that have arisen during the development activities will be addressed. The final focus will be on some of the questions that, because of the new technology, can now be addressed and are presenting new challenges.


Assuntos
Gráficos por Computador , Coroas , Restauração Dentária Permanente , Humanos , Processamento de Sinais Assistido por Computador , Software
9.
Am J Orthod ; 88(5): 425-32, 1985 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3864375

RESUMO

Posttreatment occlusion following orthognathic surgery is often different from that predicted in the treatment plan. Differences between intended and actual occlusion may be treatment-induced occlusal errors caused by mismatches between the centers of rotation of the mandible and of the articulated models. Discrepancies in the position of the articulator center of rotation (relative to the position of the center of rotation of the patient's mandible) influence the magnitude of occlusal errors. A computer model was developed to quantify these errors. As the center of rotation of the articulated models becomes more divergent from the patient's center of rotation, the magnitude of the occlusal errors increases. This magnitude increases most rapidly along the line that is perpendicular to the line joining the patient's center of rotation and a preselected mandibular landmark (incisor tip or molar cusp, for instance). For small changes in vertical dimension, clinically insignificant errors result, independent of the degree of mismatch between the centers of rotation. Clinical implications of these findings are discussed.


Assuntos
Oclusão Dentária Central , Má Oclusão/cirurgia , Mandíbula/patologia , Modelos Biológicos , Dimensão Vertical , Computadores , Articuladores Dentários , Humanos , Incisivo/anatomia & histologia , Registro da Relação Maxilomandibular , Má Oclusão/patologia , Dente Molar/anatomia & histologia , Complicações Pós-Operatórias/etiologia , Rotação
10.
J Prosthet Dent ; 54(1): 118-21, 1985 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3860647

RESUMO

The movement of the mesiolingual cusp of the maxillary left first molar was studied in the frontal and horizontal planes. The movement was studied while varying the top wall, rear wall, and incisal guidance on the articulator. It can be concluded that the top wall inclination may significantly influence movement of the mesisolingual cusp of the maxillary first molar during working mandibular movement, the rear wall inclination has less influence than top wall inclination on cusp movement during a working mandibular movement, and the working side condylar movement should be considered when evaluating or restoring the dentition.


Assuntos
Oclusão Dentária , Côndilo Mandibular/fisiologia , Dente Molar/fisiologia , Articuladores Dentários , Humanos , Maxila , Dente Molar/anatomia & histologia , Movimento
13.
Am J Orthod ; 78(3): 310-20, 1980 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-6931495

RESUMO

Various morphologies of human models are modeled with various growth patterns to demonstrate the role of mandibular morphology on growth contributions to Class II corrections. Growth patterns are described by centers of mandibular rotation relative to the cranial base. Centers of rotation are used to determine several parameters of growth generated by a computer programmed to show growth effects. The direction and amount of condylar growth are held constant. With condylar growth constant, various centers of rotation of the mandible reveal that maximum Class II molar correction is present when the condyle is vertically located farthest from the molar. Of lesser importance, Class II corrections are greater when the condyle is anteroposteriorly closest to the molar.


Assuntos
Má Oclusão Classe II de Angle/terapia , Má Oclusão/terapia , Mandíbula/crescimento & desenvolvimento , História do Século XVIII , Humanos , Má Oclusão Classe II de Angle/patologia , Mandíbula/anatomia & histologia , Mandíbula/fisiologia , Côndilo Mandibular/crescimento & desenvolvimento , Modelos Biológicos , Dente Molar/fisiologia , Movimento , Rotação
14.
Am J Orthod ; 74(4): 388-95, 1978 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-281141

RESUMO

Growth of the orofacial region is quantitatively described by locating the center of mandibular rotation relative to the cranial base. The center of mandibular rotation is positioned by the ratio of vertical facial growth (AFH/PFH) and the direction of condylar growth. Appliance therapy is associated with changes in the means of both of these parameters. These changes reduce or stop favorable anterior mandibular rotation and redirect the mean condylar growth vector more posteriorly. When appliance therapy is stopped, these parameters return toward their resting values. The mean direction of the condylar growth vector became even more anteriorly directed after treatment than the pretreatment mean value. These data support the hypothesis that orthodontic appliances significantly alter the facial growth pattern and when they are stopped, the growth pattern tends to rebound to or beyond the pretreatment values.


Assuntos
Aparelhos Ativadores , Má Oclusão Classe II de Angle/terapia , Mandíbula/crescimento & desenvolvimento , Aparelhos Ortodônticos Removíveis , Aparelhos Ortodônticos , Adolescente , Criança , Humanos , Côndilo Mandibular/crescimento & desenvolvimento , Desenvolvimento Maxilofacial , Rotação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...