Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mikrochim Acta ; 191(3): 134, 2024 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353778

RESUMO

Salivary pH serves as a valuable and useful diagnostic marker for periodontal disease, as it not only plays a critical role in disease prevention but also in its development. Typically, saliva sampling is collected by draining and spitting it into collection tubes or using swabs. In this study, we have developed a Point-of-Care (POC) device for in situ determination of oral pH without the need for complex instruments, relying solely on a smartphone as the detection device. Our system utilizes a non-toxic vegetable colourimetric indicator, immobilized on a chitosan membrane located on a disposable stick, enabling direct sampling within the buccal cavity. An ad hoc designed 3D-printed attachment is used to ensure accurate positioning and alignment of the stick, as well as isolation from external lighting conditions. A custom-developed smartphone application captures and automatically processes the image of the sensing membrane, providing the salivary pH results. After optimizing the cocktail composition, the developed sensors demonstrated the capacity to determine pH within a range of 5.4 to 8.1 with a remarkable precision of 0.6%, achieving a very short analysis time of just 1 min. A stability study conducted on the sensing membranes revealed a lifetime of 50 days. To validate the performance of our analytical device, we compared its results against those obtained from a calibrated pH-meter, using a group of individuals. The device exhibited an average error of 2.4% when compared with the pH-meter results, confirming its reliability and accuracy.


Assuntos
Quitosana , Smartphone , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Concentração de Íons de Hidrogênio
2.
Lab Chip ; 23(18): 4092-4103, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37615614

RESUMO

Understanding the phenomenon of liquid wicking in porous media is crucial for various applications, including the transportation of fluids in soils, the absorption of liquids in textiles and paper, and the development of new and efficient microfluidic paper-based analytical devices (µPADs). Hence, accurate and real-time monitoring of the liquid wicking process is essential to enable precise flow transport and control in microfluidic devices, thus enhancing their performance and usefulness. However, most existing flow monitoring strategies require external instrumentation, are generally bulky and unsuitable for portable systems. In this work, we present a portable, compact, and cost-effective electronic platform for real-time and wireless flow monitoring of liquid wicking in paper strips. The developed microcontroller-based system enables flow and flow rate monitoring based on the capacitance measurement of a pair of electrodes patterned beneath the paper strip along the liquid path, with an accuracy of 4 fF and a full-scale range of 8 pF. Additionally to the wired transmission of the monitored data to a computer via USB, the liquid wicking process can be followed in real-time via Bluetooth using a custom-developed smartphone application. The performance of the capacitive monitoring platform was evaluated for different aqueous solutions (purified water and 1 M NaCl solution), various paper strip geometries, and several custom-made chemical valves for flow retention (chitosan-, wax-, and sucrose-based barriers). The experimental validation delivered a full-scale relative error of 0.25%, resulting in an absolute capacitance error of ±10 fF. In terms of reproducibility, the maximum uncertainty was below 10 nl s-1 for flow rate determination in this study. Furthermore, the experimental data was compared and validated with numerical analysis through electrical and flow dynamics simulations in porous media, providing crucial information on the wicking process, its physical parameters, and liquid flow dynamics.

3.
Biosens Bioelectron ; 230: 115268, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37030262

RESUMO

The COVID-19 pandemic has highlighted the need for innovative approaches to its diagnosis. Here we present CoVradar, a novel and simple colorimetric method that combines nucleic acid analysis with dynamic chemical labeling (DCL) technology and the Spin-Tube device to detect SARS-CoV-2 RNA in saliva samples. The assay includes a fragmentation step to increase the number of RNA templates for analysis, using abasic peptide nucleic acid probes (DGL probes) immobilized to nylon membranes in a specific dot pattern to capture RNA fragments. Duplexes are formed by labeling complementary RNA fragments with biotinylated SMART bases, which act as templates for DCL. Signals are generated by recognizing biotin with streptavidin alkaline phosphatase and incubating with a chromogenic substrate to produce a blue precipitate. CoVradar results are analysed by CoVreader, a smartphone-based image processing system that can display and interpret the blotch pattern. CoVradar and CoVreader provide a unique molecular assay capable of detecting SARS-CoV-2 viral RNA without the need for extraction, preamplification, or pre-labeling steps, offering advantages in terms of time (∼3 h/test), cost (∼€1/test manufacturing cost) and simplicity (does not require large equipment). This solution is also promising for developing assays for other infectious diseases.


Assuntos
Técnicas Biossensoriais , COVID-19 , Aplicativos Móveis , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , RNA Viral/genética , RNA Viral/análise , Pandemias , Técnicas Biossensoriais/métodos , Smartphone , Técnicas de Amplificação de Ácido Nucleico/métodos
4.
Talanta ; 216: 120985, 2020 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-32456894

RESUMO

In this work, a freshness colorimetric sensor has been integrated with pork meat packages. The sensor tracks rising CO2 levels in the package associated with meat spoilage, as CO2 levels increase with bacterial population. The color of the sensor changes depending on the quantity of bacteria present, therefore it can be correlated with the freshness of meat, in this case pork loin. Detection is achieved by a simple photograph using a smartphone, and analyzing the grey scale from the RGB space color with a custom made app. Only 2 µL of the cocktail (all components are nontoxic) is needed to prepare the sensor, which have been integrated inside meat packages using a variety of support materials prior to sealing. The Smartphone measurements have been validated using a reference method (Checkpoint Analyzer) and the results suggest it can provide the basis for a quick test of the quality of the packaged pork.


Assuntos
Colorimetria , Carne/análise , Smartphone , Animais , Embalagem de Alimentos , Carne/microbiologia , Suínos
5.
Biosens Bioelectron ; 141: 111360, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31176114

RESUMO

A versatile, compact and low-cost analytical platform has been designed, tested and validated to be used in the point-of-care settings. This passive measurement system is powered and complemented by a standard smartphone including a programmed application for measurement configuration and data processing as well as wireless results sharing. Electrochemical and electrochemiluminescence analytical techniques can be configured and realized by this platform that employs standard screen-printed electrodes for the sample managing and off-the-shelf electronic components. The power, electrical and optical signal processing have been studied in depth. The system can harvest energy up to 22.5 mW, set up a voltage in the range of ±1.15 V, and measure potentials in a range of 600 mV with an uncertainty of 1 mV, and current from 2 µA to 0.75 mA with a resolution of 1.1 µA. Moreover, standard tests have been performed to the platform consisting of amperometric, potentiometric, cyclic voltammetry and electrochemiluminescent analytical techniques, showing excellent agreement with a reference instrument. Finally, our design has also been applied to glucose, pH and H2O2 determinations, providing the full analytical parameters which are in very good agreement with the reference instrument results. Ranges (0.065-0.75 M, 0.62-100 mM and 3-9 pH units for glucose, H2O2 and pH, respectively) and limits of detection (0.024 M and 0.03 mM for glucose and H2O2, respectively) make this low-cost platform (

Assuntos
Técnicas Biossensoriais/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Smartphone/instrumentação , Desenho de Equipamento , Glucose/análise , Humanos , Peróxido de Hidrogênio/análise , Concentração de Íons de Hidrogênio , Limite de Detecção , Tecnologia sem Fio/instrumentação
6.
Biosens Bioelectron ; 136: 47-52, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31035026

RESUMO

A combined thread-paper microfluidic device (µTPAD) is presented for the determination of glucose in blood. The device is designed to include all the analytical operations needed: red blood cell separation, conditioning, enzymatic recognition, and colorimetric transduction. The signal is captured with a smartphone or tablet working in video mode and processed by custom Android-based software in real-time. The automatic detection of the region of interest on the thread allows for the use of either initial rate or equilibrium signal as analytical parameters. The time needed for analysis is 12 s using initial rate, and 100 s using the equilibrium measurement with a LOD of 48 µM and 12 µM, respectively, and a precision around 7%. The µTPAD allows a rapid determination of glucose in real samples using only 3 µL of whole blood.


Assuntos
Glicemia/análise , Dispositivos Lab-On-A-Chip , Smartphone , Colorimetria/instrumentação , Humanos , Software
7.
ACS Sens ; 4(2): 421-426, 2019 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-30667218

RESUMO

Creatinine is a metabolite present in urine, and its concentration is used to diagnose and monitor kidney performance. For that reason, the development of new sensors to analyze this metabolite and obtain accurate results in a short period of time is necessary. An optical disposable sensor for monitoring creatinine levels in urine is described. The system, based on a new aryl-substituted calix[4]pyrrole synthetic receptor, has an unusual coextraction scheme. Due to the low p Ka values of creatininium (p Ka 4.8), a careful selection of a lipophilic pH indicator that works in acid medium is required. The sensor components were optimized, and the new sensor displays a good response time to creatinine (approximately 3 min) over a wide dynamic range (from 1 × 10-5 to 1 × 10-2 M). Moreover, the optical selectivity coefficients obtained for creatinine over common cations present in urine meet the requirements for real sample measurements. With a good sensor-to-sensor reproducibility (RSD, 5.1-6.9% in the middle of the range), this method provides a simple, quick, cost-effective, and selective alternative to the conventional methodology based on Jaffé's reaction.


Assuntos
Creatinina/urina , Ionóforos/química , Dispositivos Ópticos , Urinálise/instrumentação , Calibragem , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Membranas Artificiais
8.
Anal Chem ; 88(10): 5331-7, 2016 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-27077212

RESUMO

This paper presents a thread-based microfluidic device (µTAD) that includes ionophore extraction chemistry for the optical recognition of potassium. The device is 1.5 cm × 1.0 cm and includes a cotton thread to transport the aqueous sample via capillary wicking to a 5 mm-long detection area, where the recognition chemistry is deposited that reaches equilibrium in 60 s, changing its color between blue and magenta. A complete characterization of the cotton thread used as well as the sensing element has been carried out. The imaging of the µTAD with a digital camera and the extraction of the H coordinate of the HSV color space used as the analytical parameter make it possible to determine K(I) between 2.4 × 10(-5) and 0.95 M with a precision better than 1.3%.

9.
Anal Chim Acta ; 899: 23-56, 2015 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-26547492

RESUMO

Chemical analysis based on colour changes recorded with imaging devices is gaining increasing interest. This is due to its several significant advantages, such as simplicity of use, and the fact that it is easily combinable with portable and widely distributed imaging devices, resulting in friendly analytical procedures in many areas that demand out-of-lab applications for in situ and real-time monitoring. This tutorial review covers computer vision-based analytical (CVAC) procedures and systems from 2005 to 2015, a period of time when 87.5% of the papers on this topic were published. The background regarding colour spaces and recent analytical system architectures of interest in analytical chemistry is presented in the form of a tutorial. Moreover, issues regarding images, such as the influence of illuminants, and the most relevant techniques for processing and analysing digital images are addressed. Some of the most relevant applications are then detailed, highlighting their main characteristics. Finally, our opinion about future perspectives is discussed.

10.
Anal Chem ; 86(19): 9554-62, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25158126

RESUMO

In this work, an Android application for measurement of nitrite concentration and pH determination in combination with a low-cost paper-based microfluidic device is presented. The application uses seven sensing areas, containing the corresponding immobilized reagents, to produce selective color changes when a sample solution is placed in the sampling area. Under controlled conditions of light, using the flash of the smartphone as a light source, the image captured with the built-in camera is processed using a customized algorithm for multidetection of the colored sensing areas. The developed image-processing allows reducing the influence of the light source and the positioning of the microfluidic device in the picture. Then, the H (hue) and S (saturation) coordinates of the HSV color space are extracted and related to pH and nitrite concentration, respectively. A complete characterization of the sensing elements has been carried out as well as a full description of the image analysis for detection. The results show good use of a mobile phone as an analytical instrument. For the pH, the resolution obtained is 0.04 units of pH, 0.09 of accuracy, and a mean squared error of 0.167. With regard to nitrite, 0.51% at 4.0 mg L(-1) of resolution and 0.52 mg L(-1) as the limit of detection was achieved.


Assuntos
Telefone Celular , Colorimetria/métodos , Concentração de Íons de Hidrogênio , Microfluídica/instrumentação , Nitritos/análise , Papel
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...