PM R ; 11(6): 631-639, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30367999

RESUMO

BACKGROUND: Neck pain is one of the most common causes of chronic pain and the fourth leading cause of disability worldwide; it is estimated that between 36% and 67% of this pain is due to facet arthropathy. For patients who have pain refractory to conservative treatments literature supports management with diagnostic cervical medial branch blocks (MBBs) to identify the associated facet innervation as the source of pain followed by therapeutic radiofrequency ablation (RFA) of the identified nerves. Cervical RFA has good published outcomes; however, the procedure is dependent upon the specificity of the diagnostic block to achieve maximal success. Currently, this prerequisite test has false positive rates between 27% and 63% and recent studies have shown that this may, in part, be a consequence of currently accepted injection volumes of 0.50 mL or more, which may decrease the sensitivity of MBBs. OBJECTIVE: To evaluate the possible differences in volume dispersion between 0.25 and 0.50 mL of injectate during cervical MBBs. STUDY DESIGN: Cadaveric study. SETTING: An academic medical center in the United States. PATIENTS: Not applicable. METHODS: This was a cadaveric study in which six subjects were chosen with intact cervical spines. Cervical MBB were performed bilaterally at the midcervical spine, using a posterior approach under fluoroscopic guidance. 0.25 or 0.50 mL of a 9:1 solution of Omnipaque 180 mg iodine/mL and 1% medical grade methylene blue were administered on the left and right sides, respectively. Postinjection computed tomography (CT) imaging and gross dissection were performed to assess injectate spread. MAIN OUTCOME MEASURES: Outcome measures after using commonly injected volumes for cervical MBB, included visualized and measured spread (by CT and gross dissection) of cervical medial branch blocks, coating adjacent structures not targeted by RFA. RESULTS: Postinjection CT imaging and cadaveric dissection demonstrated that, although both volumes adequately coated the medial branches, the 0.50 mL cohort reliably spread dorsally to superficial muscles (splenius) and nerves distant from the targeted nerves (dorsal motor branches to splenius), whereas the 0.25 mL injectate cohort was contained in the deep and intermediate muscular cervical layers directly juxtaposed to the targeted cMBBs. CONCLUSION: Results suggest that 0.50 mL injections of local anesthetic during cervical MBBs contacts many nonintended targets, thus decreasing the specificity of a targeted diagnostic cervical MBB. Furthermore, we demonstrated that 0.25 mL of injectate reliably bathed the cervical medial branches without extensive extravasation. This indicates that there would potentially be fewer local anesthetic effects on distant tissues, increasing the specificity of cervical MBBs and likely improving RFA planning.


Assuntos
Vértebras Cervicais/anatomia & histologia , Meios de Contraste/administração & dosagem , Bloqueio Nervoso/métodos , Nervos Espinhais/anatomia & histologia , Músculos do Dorso/anatomia & histologia , Cadáver , Vértebras Cervicais/diagnóstico por imagem , Dor Crônica/terapia , Fluoroscopia , Humanos , Injeções Intra-Articulares , Injeções Espinhais , Iohexol/administração & dosagem , Azul de Metileno/administração & dosagem , Cervicalgia/terapia , Ablação por Radiofrequência , Nervos Espinhais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação Zigapofisária
2.
PM R ; 10(6): 616-622, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29174073

RESUMO

BACKGROUND: Lumbar facet arthropathy is a common cause of low back pain. Literature supports treatment with radiofrequency ablation (RFA) of associated nerves that innervate lumbar facets when alternative conservative therapies have failed. Diagnostic local anesthetic blocks precede therapeutic ablation, but have a false-positive rate of 27%-63%, and some authors have questioned their utility in predicting therapeutic response to RFA. The authors of the current study believe that injectate volume may be a contributing factor to false positivity. OBJECTIVE: To evaluate the difference in volume dispersion between 0.25 mL and 0.5 mL of injectate when performing lumbar medial branch blocks. We hypothesized that injection volumes greater than 0.25 mL during lumbar medial branch blocks would affect the distal branches of the adjacent medial branches, thus decreasing the specificity of the procedure. Thus, we attempted to demonstrate that injection volumes greater than 0.25 mL during lumbar medial branch blocks would affect the distal branches of the adjacent medial branches, which might increase false positivity of the blocks. STUDY DESIGN: Cadaveric investigation. SETTING: Tertiary care center. PARTICIPANTS: Not applicable. OUTCOME MEASUREMENTS: To demonstrate that the spread of lumbar medial branch blocks using commonly injected volume coats adjacent structures that are not affected by radiofrequency ablation. METHODS: Six cadavers were chosen with nondissected lumbar spines. Fluoroscopically guided medial branch injections were performed bilaterally using the posterior oblique approach. A volume of 0.25 mL or 0.50 mL of a 9:1 solution of Omnipaque 240 and 1% medical grade methylene blue were delivered to the left and right sides, respectively. Postinjection computed tomographic imaging was performed, followed by dissection. RESULTS: Both volumes adequately coated the medial branches, but in the 0.5-mL injectate cohort there was consistent spread dorsally to the superficial muscles and distal segments of the dorsal branches distant to the target nerves, whereas in the 0.25-mL injectate cohort the spread was contained in the deep and intermediate muscular lumbar layers, close to the intended target. CONCLUSION: We suggest that a 0.5-mL injectate volume in clinical practice may produce an adjacent-level nerve block in addition to the intended injection level, thus decreasing the specificity of a targeted lumbar medial branch block. A 0.25-mL quantity of injectate reliably contacted the lumbar medial branches without extensive extravasation. Presumably, this means that 0.25 mL total volume for a lumbar medial branch block may provide greater specificity for RFA planning. LEVEL OF EVIDENCE: NA.


Assuntos
Anestésicos Locais/administração & dosagem , Ablação por Cateter/métodos , Artropatias/terapia , Vértebras Lombares , Bloqueio Nervoso/métodos , Cadáver , Fluoroscopia , Humanos , Injeções , Artropatias/diagnóstico , Pessoa de Meia-Idade