Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JAMA Netw Open ; 5(8): e2227134, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35976649

RESUMO

Importance: The ThermoCool SmartTouch catheter (ablation catheter with contact force and 6-hole irrigation [CF-I6]) is approved by the US Food and Drug Administration (FDA) for paroxysmal atrial fibrillation (AF) ablation and used in routine clinical practice for persistent AF ablation, although clinical outcomes for this indication are unknown. There is a need to understand whether data from routine clinical practice can be used to conduct regulatory-grade evaluations and support label expansions. Objective: To use health system data to compare the safety and effectiveness of the CF-I6 catheter for persistent AF ablation with the ThermoCool SmartTouch SurroundFlow catheter (ablation catheter with contact force and 56-hole irrigation [CF-I56]), which is approved by the FDA for this indication. Design, Setting, and Participants: This retrospective, comparative-effectiveness cohort study included patients undergoing catheter ablation for persistent AF at Mercy Health or Mayo Clinic from January 1, 2014, to April 30, 2021, with up to a 1-year follow-up using electronic health record data. Exposures: Use of the CF-I6 or CF-I56 catheter. Main Outcomes and Measures: The primary safety outcome was a composite of death, thromboembolic events, and procedural complications within 7 to 90 days. The exploratory effectiveness outcome was a composite of AF-related hospitalization events after a 90-day blanking period. Propensity score weighting was used to balance baseline covariates. Risk differences were estimated between catheter groups and averaged across the 2 health care systems, testing for noninferiority of the CF-I6 vs the CF-I56 catheter with respect to the safety outcome using 2-sided 90% CIs. Results: Overall, 1450 patients (1034 [71.3%] male; 1397 [96.3%] White) underwent catheter ablation for persistent AF, including 949 at Mercy Health (186 CF-I6 and 763 CF-I56; mean [SD] age, 64.9 [9.2] years) and 501 at Mayo Clinic (337 CF-I6 and 164 CF-I56; mean [SD] age, 63.7 [9.5] years). A total of 798 (55.0%) had been treated with class I or III antiarrhythmic drugs before ablation. The safety outcome (CF-I6 - CF-I56) was similar at both Mercy Health (1.3%; 90% CI, -2.1% to 4.6%) and Mayo Clinic (-3.8%; 90% CI, -11.4% to 3.7%); the mean difference was noninferior, with a mean of 0.5% (90% CI, -2.6% to 3.5%; P < .001). The effectiveness was similar at 12 months between the 2 catheter groups (mean risk difference, -1.8%; 90% CI, -7.3% to 3.7%). Conclusions and Relevance: In this cohort study, the CF-I6 catheter met the prespecified noninferiority safety criterion for persistent AF ablation compared with the CF-I56 catheter, and effectiveness was similar. This study demonstrates the ability of electronic health care system data to enable safety and effectiveness evaluations of medical devices.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
2.
J Am Med Inform Assoc ; 28(10): 2241-2250, 2021 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-34313748

RESUMO

OBJECTIVE: The study sought to conduct an informatics analysis on the National Evaluation System for Health Technology Coordinating Center test case of cardiac ablation catheters and to demonstrate the role of informatics approaches in the feasibility assessment of capturing real-world data using unique device identifiers (UDIs) that are fit for purpose for label extensions for 2 cardiac ablation catheters from the electronic health records and other health information technology systems in a multicenter evaluation. MATERIALS AND METHODS: We focused on data capture and transformation and data quality maturity model specified in the National Evaluation System for Health Technology Coordinating Center data quality framework. The informatics analysis included 4 elements: the use of UDIs for identifying device exposure data, the use of standardized codes for defining computable phenotypes, the use of natural language processing for capturing unstructured data elements from clinical data systems, and the use of common data models for standardizing data collection and analyses. RESULTS: We found that, with the UDI implementation at 3 health systems, the target device exposure data could be effectively identified, particularly for brand-specific devices. Computable phenotypes for study outcomes could be defined using codes; however, ablation registries, natural language processing tools, and chart reviews were required for validating data quality of the phenotypes. The common data model implementation status varied across sites. The maturity level of the key informatics technologies was highly aligned with the data quality maturity model. CONCLUSIONS: We demonstrated that the informatics approaches can be feasibly used to capture safety and effectiveness outcomes in real-world data for use in medical device studies supporting label extensions.


Assuntos
Registros Eletrônicos de Saúde , Sistemas de Informação em Saúde , Estudos de Viabilidade , Informática , Processamento de Linguagem Natural
3.
BMJ Surg Interv Health Technol ; 3(1): e000089, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047806

RESUMO

OBJECTIVES: To determine the feasibility of using real-world data to assess the safety and effectiveness of two cardiac ablation catheters for the treatment of persistent atrial fibrillation and ischaemic ventricular tachycardia. DESIGN: Retrospective cohort. SETTING: Three health systems in the USA. PARTICIPANTS: Patients receiving ablation with the two ablation catheters of interest at any of the three health systems. MAIN OUTCOME MEASURES: Feasibility of identifying the medical devices and participant populations of interest as well as the duration of follow-up and positive predictive values (PPVs) for serious safety (ischaemic stroke, acute heart failure and cardiac tamponade) and effectiveness (arrhythmia-related hospitalisation) clinical outcomes of interest compared with manual chart validation by clinicians. RESULTS: Overall, the catheter of interest for treatment of persistent atrial fibrillation was used for 4280 ablations and the catheter of interest for ischaemic ventricular tachycardia was used 1516 times across the data available within the three health systems. The duration of patient follow-up in the three health systems ranged from 91% to 97% at ≥7 days, 89% to 96% at ≥30 days, 77% to 90% at ≥6 months and 66% to 84% at ≥1 year. PPVs were 63.4% for ischaemic stroke, 96.4% for acute heart failure, 100% at one health system for cardiac tamponade and 55.7% for arrhythmia-related hospitalisation. CONCLUSIONS: It is feasible to use real-world health system data to evaluate the safety and effectiveness of cardiac ablation catheters, though evaluations must consider the implications of variation in follow-up and endpoint ascertainment among health systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...