1.
Mater Sci Eng C Mater Biol Appl ; 45: 411-20, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25491846

RESUMO

Three super alloy candidates (X1 CrNiMoMnW 24-22-6-3-2 N, NiCr21 MoNbFe 8-3-5 AlTi, CoNiCr 35-20 Mo 10 BTi) for a prolonged contact with skin are evaluated in comparison with two reference austenitic stainless steels 316L and 904L. Several electrochemical parameters were measured and determined (E(oc), E(corr), i(corr), b(a), b(c), E(b), R(p), E(crev) and coulometric analysis) in order to compare the corrosion behavior. The cation release evaluation and in vitro biological characterization also were performed. In terms of corrosion, the results reveal that the 904L steels presented the best behavior followed by the super austenitic steel X1 CrNiMoMnW 24-22-6-3-2 N. For the other two super alloys (NiCr and CoNiCr types alloys) tested in different conditions (annealed, work hardened and work hardened+age hardened) it was found that their behavior to corrosion was weak and close to the other reference stainless steel, 316L. Regarding the extraction a mixture of cations in relatively high concentrations was noted and therefore a cocktail effect was not excluded. The results obtained in the biological assays WST-1 and TNF-alpha were in correlation with the corrosion and extraction evaluation.


Assuntos
Ligas/química , Cátions/química , Aço Inoxidável/química , Animais , Materiais Biocompatíveis/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Corrosão , Eletroquímica , Células HeLa , Células Endoteliais da Veia Umbilical Humana , Humanos , Molécula 1 de Adesão Intercelular/metabolismo , Teste de Materiais , Metais/química , Camundongos , Fator de Necrose Tumoral alfa/metabolismo
2.
Mater Sci Eng C Mater Biol Appl ; 34: 69-77, 2014 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-24268235

RESUMO

The requirement for revision surgery of total joint replacements is increasing and modular joint replacement implants have been developed to provide adjustable prosthetic revision systems with improved intra-operative flexibility. An electrochemical study of the corrosion resistance of the interface between the distal and proximal modules of a modular prosthesis was performed in combination with a cyclic fatigue test. The complexity resides in the existence of interfaces between the distal part, the proximal part, and the dynamometric screw. A new technique for evaluating the resistance to cyclic dynamic corrosion with crevice stimulation was used and the method is presented. In addition, two components of the proximal module of explanted Ti6Al4V and Ti6Al7Nb prostheses were investigated by optical and electron microscopy. Our results reveal that: The electrolyte penetrates into the interface between the distal and proximal modules during cyclic dynamic fatigue tests, the distal module undergoes cracking and corrosion was generated at the interface between the two models; The comparison of the explanted proximal parts with the similar prostheses evaluated following cyclic dynamic crevice corrosion testing showed that there were significant similarities indicating that this method is suitable for evaluating materials used in the fabrication of modular prostheses.


Assuntos
Teste de Materiais , Próteses e Implantes , Estresse Mecânico , Ligas , Cátions , Corrosão , Eletricidade , Técnicas Eletroquímicas , Humanos , Titânio/química
3.
Mater Sci Eng C Mater Biol Appl ; 32(6): 1452-60, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-24364945

RESUMO

In the last years the dental alloy market has undergone dramatic changes for reasons of economy and biocompatibility. Nickel based alloys have become widely used substitute for the much more expensive precious metal alloys. In Europe the prevalence of nickel allergy is 10-15% for female adults and 1-3% for male adults. Despite the restrictions imposed by the EU for the protection of the general population in contact dermatitis, the use of Ni-Cr dental alloys is on the increase. Some questions have to be faced regarding the safety risk of nickel contained in dental alloys. We have collected based on many EU markets, 8 Ni-Cr dental alloys. Microstructure characterization, corrosion resistance (generalized, crevice and pitting) in saliva and the quantities of cations released in particular nickel and CrVI have been evaluated. We have applied non parametric classification tests (Kendall rank correlation) for all chemical results. Also cytotoxicity tests and an evaluation specific to TNF-alpha have been conducted. According to the obtained results, it was found that their behavior to corrosion was weak but that nickel release was high. The quantities of nickel released are higher than the limits imposed in the EU concerning contact with the skin or piercing. Surprisingly the biological tests did not show any cytotoxic effect on Hela and L929 cells or any change in TNF-alpha expression in monocytic cells. The alloys did not show any proinflammatory response in endothelial cells as demonstrated by the absence of ICAM-1 induction. We note therefore that there is really no direct relationship between the in vitro biological evaluation tests and the physico-chemical characterization of these dental alloys. Clinical and epidemiological studies are required to clarify these aspects.


Assuntos
Ligas de Cromo/química , Ligas Dentárias/química , Níquel/química , Linhagem Celular Tumoral , Ligas de Cromo/efeitos adversos , Ligas Dentárias/efeitos adversos , Eletroquímica , Células Endoteliais/metabolismo , Células HeLa , Humanos , Teste de Materiais , Monócitos/metabolismo , Níquel/efeitos adversos , Saliva/química , Fator de Necrose Tumoral alfa/metabolismo
4.
Acta Biomater ; 4(3): 680-5, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18054530

RESUMO

The study of 316L-type stainless steel reveals a significant anisotropy of nickel release that is dependent on the orientation of the test surface with respect to the casting and rolling direction. Cross-sectional specimens (transversal cuts with respect to the rolling direction) show a substantially higher sensitivity to corrosion phenomena compared with longitudinal cuts and they release nickel ions at rates 10-100 times higher. These findings indicate that orientation needs to be taken into account when interpreting test results, in particular when comparing different grades of austenitic stainless steel, as well as in product and production design.


Assuntos
Níquel/química , Aço Inoxidável/química , Anisotropia , Corrosão , Potenciometria
5.
Acta Biomater ; 2(4): 433-44, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16765883

RESUMO

The role of nickel in the biological response to alloys used in medical devices is of immense significance with regard to toxicology and biological performance. There is now a tendency to take nickel out of alloys for medical applications. However, this needs careful evaluation since no compromise is acceptable with regard to mechanical properties, corrosion resistance or any other harmful consequences due to the nickel substitution. This paper analyses the corrosion behaviour and cations released for five austenitic steels, nominally "nickel-free". The analysis of electrochemical parameters, open circuit potential, polarisation resistance, Tafel slopes, corrosion current, breakdown potential, potentiodynamic polarisation curves, and coulometric analysis by zone, reveal that the new austenitic steels, nominally "nickel-free", do not behave in the same way. In the family of steels studied, quite a large dispersion is noted in the corrosion behaviour. With regard to the crevice corrosion behaviour, the steel grades studied can be classified into three groups, with crevice potentials of 600-650mV; 350-450mV and 100-150mV. The release of 18 cations (Al, Ba, Be, Cd, Co, Cr, Cu, Fe, Li, Mn, Mo, Ni, P, Pb, Sn, Sr, Ti, and V) was studied by extraction tests in artificial sweat and bone plasma fluid. The extraction tests reveal that the "nickel-free" steels indeed release only faint traces of nickel. Yet many other elements, some of them potentially harmful, are released in significant amounts. Generally, the amount of cations released is substantially higher in the artificial sweat solution than in the bone plasma.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Níquel/química , Aço Inoxidável/química , Suor/química , Cátions/química , Corrosão , Eletroquímica , Teste de Materiais , Fatores de Tempo
6.
Biomaterials ; 24(18): 3027-38, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12895575

RESUMO

The corrosion behavior of titanium with vacuum plasma sprayed titanium coatings and with anodized surfaces, both with and without polymeric bone cement were evaluated. Electrochemical extraction tests were carried out with subsequent analysis of the electrolyte by ICP-MS in order to verify our hypothesis of the ionic permeability of the polymer cement. The complexity of the situation resides in the existence of two interfaces: electrolyte-polymer and polymer-metal. The surface preparation (treatment of the surface) plays an important role in the corrosion resistance of titanium. The electrochemical magnitudes that were examined reveal that the plasma spray surfaces have the lowest corrosion resistance. The cement, in spite of having reduced electrical conductivity in comparison to metal, is an ionic transporter, and therefore capable of participating in the corrosion process. In the present study, we observed in fact crevice corrosion at the metal-cement interface. In the case of plasma spray surfaces, a process of diffusion of titanium particles in the electrolyte could accompany the crevice corrosion. In this study, we have shown that there is a corrosion process at the surface of the titanium through the cement which has as a consequence on the one hand the formation of titanium cations and on the other hand the growth of a passive layer on the titanium. In conclusion, we identified two principal factors that influence the corrosion process: [1] the type of surface treatment for the titanium, and [2] the ionic conductivity of the cement. There is indeed ionic transport through the cement; as evidenced by the presence of titanium in the electrolyte solution (ICP-MS analysis) and chloride at the surface of the titanium sample (EDX analysis). We show that the polymer cement is an ionic conductor and participates in the corrosion of the embedded titanium. We cannot deduce from our results, however, whether the polymer itself possesses corrosive properties. Long-term experiments will be necessary to study the degradation behavior of the polymer cement.


Assuntos
Materiais Revestidos Biocompatíveis/química , Eletroquímica/métodos , Temperatura Alta , Polimetil Metacrilato/química , Próteses e Implantes , Titânio/química , Materiais Revestidos Biocompatíveis/síntese química , Corrosão , Impedância Elétrica , Análise de Falha de Equipamento , Gases , Teste de Materiais , Permeabilidade , Propriedades de Superfície
7.
Biomaterials ; 23(16): 3479-85, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12099292

RESUMO

The corrosion behavior of surgical implant CoCr alloy and REX 734 steel has been investigated. The pitting or crevice corrosion potentials have been determined to reach values as high as 500 mV vs. SCE for CoCr and 450 mV vs. SCE for REX 734. The galvanic corrosion behavior of CoCr/REX 734 couples has been evaluated with various electrochemical techniques. The measurement of the corrosion current of the galvanic couple as well as its prediction by applying mixed potential theories on measured potentiodynamic polarization curves revealed low galvanic currents in the range of nanoamperes.


Assuntos
Ligas de Cromo/química , Aço Inoxidável/química , Corrosão , Eletroquímica/métodos , Falha de Prótese , Estresse Mecânico
8.
Biomaterials ; 22(3): 269-79, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11197502

RESUMO

The corrosion behavior of combinations of materials used in an orthopedic implant: the spherical part (forged or forged and annealed) constituting the head, the weld (tungsten inert gas (TIG) or electron beam (EB) techniques), and the cylindrical part (annealed) constituting the shaft of a femoral prosthesis - has been investigated. Open-circuit potentials, potentiodynamic curves, Tafel slope, mixed potential theory and susceptibility to intergranular attack are electrochemical and chemical procedures selected for this work. Electrochemical measurements using a microelectrode have been made in the following zones: spherical part, cylindrical part, weld, and weld/sphere, and weld/shaft interfaces. To detect intergranular attack, the Strauss test has been used. At the interfaces, corrosion currents, measured (Icorr) and predicted (Icouple) are low, in the order of the pico- to nanoampere. The electrochemical behavior of the electron beam (EB) weld is better than that of the tungsten inert gas (TIG). Welds at interfaces can behave either anodically or cathodically. It is better if welds, which are sensitive parts of the femoral prosthesis, behave cathodically. In this way, the risk of starting localized corrosion (pitting, crevice or intergranular corrosion) from a galvanic couple, remains low. From this point of view, the sample with the EB weld offers the best behavior. All the other samples containing a TIG type of weld exhibit a less favorable behavior. The mechanical treatments (forged, and forged and annealed) of the steel sphere did not show any difference in the corrosion behavior. No intergranular corrosion has been observed at the weld/steel interface for unsensitized samples. With sensitized samples, however, a TIG sample has exhibited some localized intergranular corrosion at a distance of 500 microm along the weld/stainless steel (sphere) interface.


Assuntos
Ortopedia , Próteses e Implantes , Aço Inoxidável , Materiais Biocompatíveis , Corrosão , Eletroquímica , Propriedades de Superfície , Soldagem
SELEÇÃO DE REFERÊNCIAS