Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
1.
IEEE Trans Biomed Eng ; PP2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39042539

RESUMO

OBJECTIVE: Surface electromyography (sEMG) can sense the motor commands transmitted to the muscles. This work presents a deep learning method that can decode the electrophysiological activity of the forearm muscles into the movements of the human hand. METHODS: We have recorded the kinematics and kinetics of the hand during a wide range of grasps and individual digit movements that cover 22 degrees of freedom of the hand at slow (0.5 Hz) and comfortable (1.5 Hz) movement speeds in 13 healthy participants. The input of the model consists of 320 non-invasive EMG sensors placed on the extrinsic hand muscles. RESULTS: Our network achieves accurate continuous estimation of both kinematics and kinetics, surpassing the performance of comparable networks reported in the literature. By examining the latent space of the network, we find evidence that it mapped EMG activity into the anatomy of the hand at the individual digit level. In contrast to what is observed from the low-pass filtered EMG and linear decoding approaches, we found that the full-bandwidth EMG (monopolar unfiltered) signals during synergistic and individual digit movements contain distinct neural embeddings that encode each movement of the human hand. These manifolds consistently represent the anatomy of the hand and are generalized across participants. Moreover, we found a task-specific distribution of the embeddings without any presence of correlated activations during multi- and individual-digit tasks. CONCLUSION/SIGNIFICANCE: The proposed method could advance the control of assistive hand devices by providing a robust and intuitive interface between muscle signals and hand movements.

2.
J Clin Med ; 13(13)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38999454

RESUMO

Background: Disease-modifying antirheumatic drugs (bDMARDs) have shown efficacy in treating Rheumatoid Arthritis (RA). Predicting treatment outcomes for RA is crucial as approximately 30% of patients do not respond to bDMARDs and only half achieve a sustained response. This study aims to leverage machine learning to predict both initial response at 6 months and sustained response at 12 months using baseline clinical data. Methods: Baseline clinical data were collected from 154 RA patients treated at the University Hospital in Erlangen, Germany. Five machine learning models were compared: Extreme Gradient Boosting (XGBoost), Adaptive Boosting (AdaBoost), K-nearest neighbors (KNN), Support Vector Machines (SVM), and Random Forest. Nested cross-validation was employed to ensure robustness and avoid overfitting, integrating hyperparameter tuning within its process. Results: XGBoost achieved the highest accuracy for predicting initial response (AUC-ROC of 0.91), while AdaBoost was the most effective for sustained response (AUC-ROC of 0.84). Key predictors included the Disease Activity Score-28 using erythrocyte sedimentation rate (DAS28-ESR), with higher scores at baseline associated with lower response chances at 6 and 12 months. Shapley additive explanations (SHAP) identified the most important baseline features and visualized their directional effects on treatment response and sustained response. Conclusions: These findings can enhance RA treatment plans and support clinical decision-making, ultimately improving patient outcomes by predicting response before starting medication.

3.
Eur J Neurol ; 31(8): e16367, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38859620

RESUMO

BACKGROUND AND PURPOSE: Hereditary spastic paraplegias (HSPs) comprise a group of inherited neurodegenerative disorders characterized by progressive spasticity and weakness. Botulinum toxin has been approved for lower limb spasticity following stroke and cerebral palsy, but its effects in HSPs remain underexplored. We aimed to characterize the effects of botulinum toxin on clinical, gait, and patient-reported outcomes in HSP patients and explore the potential of mobile digital gait analysis to monitor treatment effects and predict treatment response. METHODS: We conducted a prospective, observational, multicenter study involving ambulatory HSP patients treated with botulinum toxin tailored to individual goals. Comparing data at baseline, after 1 month, and after 3 months, treatment response was assessed using clinical parameters, goal attainment scaling, and mobile digital gait analysis. Machine learning algorithms were used for predicting individual goal attainment based on baseline parameters. RESULTS: A total of 56 patients were enrolled. Despite the heterogeneity of treatment goals and targeted muscles, botulinum toxin led to a significant improvement in specific clinical parameters and an improvement in specific gait characteristics, peaking at the 1-month and declining by the 3-month follow-up. Significant correlations were identified between gait parameters and clinical scores. With a mean balanced accuracy of 66%, machine learning algorithms identified important denominators to predict treatment response. CONCLUSIONS: Our study provides evidence supporting the beneficial effects of botulinum toxin in HSP when applied according to individual treatment goals. The use of mobile digital gait analysis and machine learning represents a novel approach for monitoring treatment effects and predicting treatment response.


Assuntos
Análise da Marcha , Paraplegia Espástica Hereditária , Humanos , Masculino , Feminino , Paraplegia Espástica Hereditária/tratamento farmacológico , Adulto , Pessoa de Meia-Idade , Análise da Marcha/métodos , Estudos Prospectivos , Fármacos Neuromusculares/farmacologia , Fármacos Neuromusculares/administração & dosagem , Fármacos Neuromusculares/uso terapêutico , Resultado do Tratamento , Toxinas Botulínicas Tipo A/uso terapêutico , Toxinas Botulínicas Tipo A/farmacologia , Adulto Jovem , Idoso , Toxinas Botulínicas/uso terapêutico
4.
Front Bioeng Biotechnol ; 12: 1386874, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38919383

RESUMO

Musculoskeletal simulations can be used to estimate biomechanical variables like muscle forces and joint torques from non-invasive experimental data using inverse and forward methods. Inverse kinematics followed by inverse dynamics (ID) uses body motion and external force measurements to compute joint movements and the corresponding joint loads, respectively. ID leads to residual forces and torques (residuals) that are not physically realistic, because of measurement noise and modeling assumptions. Forward dynamic simulations (FD) are found by tracking experimental data. They do not generate residuals but will move away from experimental data to achieve this. Therefore, there is a gap between reality (the experimental measurements) and simulations in both approaches, the sim2real gap. To answer (patho-) physiological research questions, simulation results have to be accurate and reliable; the sim2real gap needs to be handled. Therefore, we reviewed methods to handle the sim2real gap in such musculoskeletal simulations. The review identifies, classifies and analyses existing methods that bridge the sim2real gap, including their strengths and limitations. Using a systematic approach, we conducted an electronic search in the databases Scopus, PubMed and Web of Science. We selected and included 85 relevant papers that were sorted into eight different solution clusters based on three aspects: how the sim2real gap is handled, the mathematical method used, and the parameters/variables of the simulations which were adjusted. Each cluster has a distinctive way of handling the sim2real gap with accompanying strengths and limitations. Ultimately, the method choice largely depends on various factors: available model, input parameters/variables, investigated movement and of course the underlying research aim. Researchers should be aware that the sim2real gap remains for both ID and FD approaches. However, we conclude that multimodal approaches tracking kinematic and dynamic measurements may be one possible solution to handle the sim2real gap as methods tracking multimodal measurements (some combination of sensor position/orientation or EMG measurements), consistently lead to better tracking performances. Initial analyses show that motion analysis performance can be enhanced by using multimodal measurements as different sensor technologies can compensate each other's weaknesses.

6.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38722552

RESUMO

Objective.Perinatal asphyxia poses a significant risk to neonatal health, necessitating accurate fetal heart rate monitoring for effective detection and management. The current gold standard, cardiotocography, has inherent limitations, highlighting the need for alternative approaches. The emerging technology of non-invasive fetal electrocardiography shows promise as a new sensing technology for fetal cardiac activity, offering potential advancements in the detection and management of perinatal asphyxia. Although algorithms for fetal QRS detection have been developed in the past, only a few of them demonstrate accurate performance in the presence of noise and artifacts.Approach.In this work, we proposePower-MF, a new algorithm for fetal QRS detection combining power spectral density and matched filter techniques. We benchmarkPower-MFagainst three open-source algorithms on two recently published datasets (Abdominal and Direct Fetal ECG Database: ADFECG, subsets B1 Pregnancy and B2 Labour; Non-invasive Multimodal Foetal ECG-Doppler Dataset for Antenatal Cardiology Research: NInFEA).Main results.Our results show thatPower-MFoutperforms state-of-the-art algorithms on ADFECG (B1 Pregnancy: 99.5% ± 0.5% F1-score, B2 Labour: 98.0% ± 3.0% F1-score) and on NInFEA in three of six electrode configurations by being more robust against noise.Significance.Through this work, we contribute to improving the accuracy and reliability of fetal cardiac monitoring, an essential step toward early detection of perinatal asphyxia with the long-term goal of reducing costs and making prenatal care more accessible.


Assuntos
Algoritmos , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Humanos , Eletrocardiografia/métodos , Feminino , Gravidez , Monitorização Fetal/métodos , Feto/fisiologia
7.
Front Neurosci ; 18: 1393749, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38812972

RESUMO

The human's upright standing is a complex control process that is not yet fully understood. Postural control models can provide insights into the body's internal control processes of balance behavior. Using physiologically plausible models can also help explaining pathophysiological motion behavior. In this paper, we introduce a neuromusculoskeletal postural control model using sensor feedback consisting of somatosensory, vestibular and visual information. The sagittal plane model was restricted to effectively six degrees of freedom and consisted of nine muscles per leg. Physiologically plausible neural delays were considered for balance control. We applied forward dynamic simulations and a single shooting approach to generate healthy reactive balance behavior during quiet and perturbed upright standing. Control parameters were optimized to minimize muscle effort. We showed that our model is capable of fulfilling the applied tasks successfully. We observed joint angles and ranges of motion in physiologically plausible ranges and comparable to experimental data. This model represents the starting point for subsequent simulations of pathophysiological postural control behavior.

8.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691395

RESUMO

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

9.
Front Bioeng Biotechnol ; 12: 1285845, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38628437

RESUMO

Portable measurement systems using inertial sensors enable motion capture outside the lab, facilitating longitudinal and large-scale studies in natural environments. However, estimating 3D kinematics and kinetics from inertial data for a comprehensive biomechanical movement analysis is still challenging. Machine learning models or stepwise approaches performing Kalman filtering, inverse kinematics, and inverse dynamics can lead to inconsistencies between kinematics and kinetics. We investigated the reconstruction of 3D kinematics and kinetics of arbitrary running motions from inertial sensor data using optimal control simulations of full-body musculoskeletal models. To evaluate the feasibility of the proposed method, we used marker tracking simulations created from optical motion capture data as a reference and for computing virtual inertial data such that the desired solution was known exactly. We generated the inertial tracking simulations by formulating optimal control problems that tracked virtual acceleration and angular velocity while minimizing effort without requiring a task constraint or an initial state. To evaluate the proposed approach, we reconstructed three trials each of straight running, curved running, and a v-cut of 10 participants. We compared the estimated inertial signals and biomechanical variables of the marker and inertial tracking simulations. The inertial data was tracked closely, resulting in low mean root mean squared deviations for pelvis translation (≤20.2 mm), angles (≤1.8 deg), ground reaction forces (≤1.1 BW%), joint moments (≤0.1 BWBH%), and muscle forces (≤5.4 BW%) and high mean coefficients of multiple correlation for all biomechanical variables (≥0.99). Accordingly, our results showed that optimal control simulations tracking 3D inertial data could reconstruct the kinematics and kinetics of individual trials of all running motions. The simulations led to mutually and dynamically consistent kinematics and kinetics, which allows researching causal chains, for example, to analyze anterior cruciate ligament injury prevention. Our work proved the feasibility of the approach using virtual inertial data. When using the approach in the future with measured data, the sensor location and alignment on the segment must be estimated, and soft-tissue artifacts are potential error sources. Nevertheless, we demonstrated that optimal control simulation tracking inertial data is highly promising for estimating 3D kinematics and kinetics for a comprehensive biomechanical analysis.

10.
BMC Geriatr ; 24(1): 347, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627620

RESUMO

BACKGROUND: The Comprehensive Geriatric Assessment (CGA) records geriatric syndromes in a standardized manner, allowing individualized treatment tailored to the patient's needs and resources. Its use has shown a beneficial effect on the functional outcome and survival of geriatric patients. A recently published German S1 guideline for level 2 CGA provides recommendations for the use of a broad variety of different assessment instruments for each geriatric syndrome. However, the actual use of assessment instruments in routine geriatric clinical practice and its consistency with the guideline and the current state of literature has not been investigated to date. METHODS: An online survey was developed by an expert group of geriatricians and sent to all licenced geriatricians (n = 569) within Germany. The survey included the following geriatric syndromes: motor function and self-help capability, cognition, depression, pain, dysphagia and nutrition, social status and comorbidity, pressure ulcers, language and speech, delirium, and frailty. Respondents were asked to report which geriatric assessment instruments are used to assess the respective syndromes. RESULTS: A total of 122 clinicians participated in the survey (response rate: 21%); after data cleaning, 76 data sets remained for analysis. All participants regularly used assessment instruments in the following categories: motor function, self-help capability, cognition, depression, and pain. The most frequently used instruments in these categories were the Timed Up and Go (TUG), the Barthel Index (BI), the Mini Mental State Examination (MMSE), the Geriatric Depression Scale (GDS), and the Visual Analogue Scale (VAS). Limited or heterogenous assessments are used in the following categories: delirium, frailty and social status. CONCLUSIONS: Our results show that the assessment of motor function, self-help capability, cognition, depression, pain, and dysphagia and nutrition is consistent with the recommendations of the S1 guideline for level 2 CGA. Instruments recommended for more frequent use include the Short Physical Performance Battery (SPPB), the Montreal Cognitive Assessment (MoCA), and the WHO-5 (depression). There is a particular need for standardized assessment of delirium, frailty and social status. The harmonization of assessment instruments throughout geriatric departments shall enable more effective treatment and prevention of age-related diseases and syndromes.


Assuntos
Transtornos de Deglutição , Delírio , Fragilidade , Humanos , Idoso , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Fragilidade/terapia , Avaliação Geriátrica/métodos , Dor , Inquéritos e Questionários
11.
Sci Rep ; 14(1): 8251, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589504

RESUMO

Investigating acute stress responses is crucial to understanding the underlying mechanisms of stress. Current stress assessment methods include self-reports that can be biased and biomarkers that are often based on complex laboratory procedures. A promising additional modality for stress assessment might be the observation of body movements, which are affected by negative emotions and threatening situations. In this paper, we investigated the relationship between acute psychosocial stress induction and body posture and movements. We collected motion data from N = 59 individuals over two studies (Pilot Study: N = 20, Main Study: N = 39) using inertial measurement unit (IMU)-based motion capture suits. In both studies, individuals underwent the Trier Social Stress Test (TSST) and a stress-free control condition (friendly-TSST; f-TSST) in randomized order. Our results show that acute stress induction leads to a reproducible freezing behavior, characterized by less overall motion as well as more and longer periods of no movement. Based on these data, we trained machine learning pipelines to detect acute stress solely from movement information, achieving an accuracy of 75.0 ± 17.7 % (Pilot Study) and 73.4 ± 7.7 % (Main Study). This, for the first time, suggests that body posture and movements can be used to detect whether individuals are exposed to acute psychosocial stress. While more studies are needed to further validate our approach, we are convinced that motion information can be a valuable extension to the existing biomarkers and can help to obtain a more holistic picture of the human stress response. Our work is the first to systematically explore the use of full-body body posture and movement to gain novel insights into the human stress response and its effects on the body and mind.


Assuntos
Estresse Psicológico , Humanos , Biomarcadores , Projetos Piloto , Postura , Saliva , Estresse Psicológico/psicologia
12.
IEEE Open J Eng Med Biol ; 5: 163-172, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487091

RESUMO

Goal: Gait analysis using inertial measurement units (IMUs) has emerged as a promising method for monitoring movement disorders. However, the lack of public data and easy-to-use open-source algorithms hinders method comparison and clinical application development. To address these challenges, this publication introduces the gaitmap ecosystem, a comprehensive set of open source Python packages for gait analysis using foot-worn IMUs. Methods: This initial release includes over 20 state-of-the-art algorithms, enables easy access to seven datasets, and provides eight benchmark challenges with reference implementations. Together with its extensive documentation and tooling, it enables rapid development and validation of new algorithm and provides a foundation for novel clinical applications. Conclusion: The published software projects represent a pioneering effort to establish an open-source ecosystem for IMU-based gait analysis. We believe that this work can democratize the access to high-quality algorithm and serve as a driver for open and reproducible research in the field of human gait analysis and beyond.

13.
Digit Health ; 10: 20552076241234627, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38528967

RESUMO

Objective: Mobile Health apps could be a feasible and effective tool to raise awareness for breast cancer prevention and to support women to change their behaviour to a healthier lifestyle. The aim of this study was to analyse the characteristics and quality of apps designed for breast cancer prevention and education. Methods: We conducted a systematic search for apps covering breast cancer prevention topics in the Google Play and Apple App Store accessible from Germany using search terms either in German or in English. Only apps with a last update after June 2020 were included. The apps identified were downloaded and evaluated by two independent researchers. App quality was analysed using the Mobile Application Rating Scale (MARS). Associations of app characteristics and MARS rating were analysed. Results: We identified 19 apps available in the Google Play Store and seven apps available in the Apple App Store that met all inclusion criteria. The mean MARS score was 3.07 and 3.50, respectively. Functionality was the highest-scoring domain. Operating system, developer (healthcare), download rates and time since the last update were significantly associated with overall MARS score. In addition, the presence of the following app functions significantly influenced MARS rating: breast self-examination tutorial, reminder for self-examination, documentation feature and education about breast cancer risk factors. Conclusions: Although most of the apps offer important features for breast cancer prevention, none of the analysed apps combined all functions. The absence of healthcare professionals' expertise in developing apps negatively affects the overall quality.

14.
Brain ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501612

RESUMO

The paralysis of the muscles controlling the hand dramatically limits the quality of life of individuals living with spinal cord injury (SCI). Here, with a non-invasive neural interface, we demonstrate that eight motor complete SCI individuals (C5-C6) are still able to task-modulate in real-time the activity of populations of spinal motor neurons with residual neural pathways. In all SCI participants tested, we identified groups of motor units under voluntary control that encoded various hand movements. The motor unit discharges were mapped into more than 10 degrees of freedom, ranging from grasping to individual hand-digit flexion and extension. We then mapped the neural dynamics into a real-time controlled virtual hand. The SCI participants were able to match the cue hand posture by proportionally controlling four degrees of freedom (opening and closing the hand and index flexion/extension). These results demonstrate that wearable muscle sensors provide access to spared motor neurons that are fully under voluntary control in complete cervical SCI individuals. This non-invasive neural interface allows the investigation of motor neuron changes after the injury and has the potential to promote movement restoration when integrated with assistive devices.

15.
Stress Health ; : e3384, 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38367241

RESUMO

Perceived stress, a global health problem associated with various mental disorders, is assumed to be influenced by dysfunctional beliefs. It can be hypothesized that these beliefs can be modified with the help of approach-avoidance modification trainings (AAMTs). In the present study (conducted 2020-2022), we aimed to clarify whether the efficacy of AAMTs can be enhanced by utilizing the expression of emotions to move AAMT stimuli. For this purpose, we tested the feasibility and acceptability of a new AAMT paradigm in which the expression of disgust is used to move stress-increasing beliefs away from oneself and the expression of positive emotions is used to move stress-reducing beliefs towards oneself (AAMT-DP). Additionally, we explored the therapeutic potential of the AAMT-DP intervention by comparing it to an inactive control condition and to a conventional AAMT in which stimuli are moved by swipe movements (n = 10 in each condition). The primary outcome was perceived stress 1 week after the training as assessed with the Perceived Stress Scale. Findings indicate sufficient feasibility and acceptability of the intervention and that the decrease in perceived stress in the AAMT-DP condition was greater than in the inactive control condition (g = 0.72 [0.10, 1.72]) and than in the swipe control condition (g = 0.64 [0.01, 1.41]). In sum, findings provide preliminary evidence for the feasibility, acceptability, and the therapeutic potential of the AAMT-DP intervention.

16.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-38243008

RESUMO

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Assuntos
Velocidade de Caminhada , Dispositivos Eletrônicos Vestíveis , Humanos , Idoso , Marcha , Caminhada , Projetos de Pesquisa
17.
JMIR Form Res ; 7: e47426, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38085558

RESUMO

BACKGROUND: Mobile eHealth apps have been used as a complementary treatment to increase the quality of life of patients and provide new opportunities for the management of rheumatic diseases. Telemedicine, particularly in the areas of prevention, diagnostics, and therapy, has become an essential cornerstone in the care of patients with rheumatic diseases. OBJECTIVE: This study aims to improve the design and technology of YogiTherapy and evaluate its usability and quality. METHODS: We newly implemented the mobile eHealth app YogiTherapy with a modern design, the option to change language, and easy navigation to improve the app's usability and quality for patients. After refinement, we evaluated the app by conducting a study with 16 patients with AS (4 female and 12 male; mean age 48.1, SD 16.8 y). We assessed the usability of YogiTherapy with a task performance test (TPT) with a think-aloud protocol and the quality with the German version of the Mobile App Rating Scale (MARS). RESULTS: In the TPT, the participants had to solve 6 tasks that should be performed on the app. The overall task completion rate in the TPT was high (84/96, 88% completed tasks). Filtering for videos and navigating to perform an assessment test caused the largest issues during the TPT, while registering in the app and watching a yoga video were highly intuitive. Additionally, 12 (75%) of the 16 participants completed the German version of MARS. The quality of YogiTherapy was rated with an average MARS score of 3.79 (SD 0.51) from a maximum score of 5. Furthermore, results from the MARS questionnaire demonstrated a positive evaluation regarding functionality and aesthetics. CONCLUSIONS: The refined and tested YogiTherapy app showed promising results among most participants. In the future, the app could serve its function as a complementary treatment for patients with AS. For this purpose, surveys with a larger number of patients should still be conducted. As a substantial advancement, we made the app free and openly available on the iOS App and Google Play stores.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38082860

RESUMO

Smartphones enable and facilitate biomedical studies as they allow the recording of various biomedical signals, including photoplethysmograms (PPG). However, user engagement rates in mobile health studies are reduced when an application (app) needs to be installed. This could be alleviated by using installation-free web apps. We evaluate the feasibility of browser-based PPG recording, conducting the first usability study on smartphone-based PPG. We present an at-home study using a web app and library for PPG recording using the rear camera and flash. The underlying library is freely made available to researchers. 25 Android users participated, using their own smartphones. The study consisted of a demographic and anamnestic questionnaire, the signal recording itself (60 s), and a consecutive usability questionnaire. After filtering, heart rate was extracted (14/17 successful), signal-to-noise ratios assessed (0.64 ± 0.50 dB, mean ± standard deviation), and quality was visually inspected (12/17 usable for diagnosis). Recording was not supported in 9 cases. This was due to the browser's insufficient support for the flash light API. The app received a System Usability Scale score of 82 ± 9, which is above the 90th percentile. Overall, browser flash light support is the main limiting factor for broad device support. Thus, browser-based PPG is not yet widely applicable, although most participants feel comfortable with the recording itself. The utilization of the user-facing camera might represent a more promising approach. This study contributes to the development of low-barrier, user-friendly, installation-free smartphone signal acquisition. This enables profound, comprehensive data collection for research and clinical practice.Clinical relevance- WebPPG offers low-barrier remote diagnostic capabilities without the need for app installation.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Fotopletismografia , Estudos de Viabilidade , Inquéritos e Questionários
19.
Artigo em Inglês | MEDLINE | ID: mdl-38083123

RESUMO

Medication optimization is a common component of the treatment strategy in patients with Parkinson's disease. As the disease progresses, it is essential to compensate for the movement deterioration in patients. Conventionally, examining motor deterioration and prescribing medication requires the patient's onsite presence in hospitals or practices. Home-monitoring technologies can remotely deliver essential information to physicians and help them devise a treatment decision according to the patient's need. Additionally, they help to observe the patient's response to these changes. In this regard, we conducted a longitudinal study to collect gait data of patients with Parkinson's disease while they received medication changes. Using logistic regression classifier, we could detect the annotated motor deterioration during medication optimization with an accuracy of 92%. Moreover, an in-depth examination of the best features illustrated a decline in gait speed and swing phase duration in the deterioration phases due to suboptimal medication.Clinical relevance- Our proposed gait analysis method in this study provides objective, detailed, and punctual information to physicians. Revealing clinically relevant time points related to the patient's need for medical adaption alleviates therapy optimization for physicians and reduces the duration of suboptimal treatment for patients. As the home-monitoring system acts remotely, embedding it in the medical care pathways could improve patients' quality of life.


Assuntos
Doença de Parkinson , Humanos , Doença de Parkinson/tratamento farmacológico , Estudos Longitudinais , Qualidade de Vida , Monitorização Fisiológica , Movimento
20.
Artigo em Inglês | MEDLINE | ID: mdl-38083405

RESUMO

Ultrasound examinations during pregnancy can detect abnormal fetal development, which is a leading cause of perinatal mortality. In multiple pregnancies, the position of the fetuses may change between examinations. The individual fetus cannot be clearly identified. Fetal re-identification may improve diagnostic capabilities by tracing individual fetal changes. This work evaluates the feasibility of fetal re-identification on FETAL_PLANES_DB, a publicly available dataset of singleton pregnancy ultrasound images. Five dataset subsets with 6,491 images from 1,088 pregnant women and two re-identification frameworks (Torchreid, FastReID) are evaluated. FastReID achieves a mean average precision of 68.77% (68.42%) and mean precision at rank 10 score of 89.60% (95.55%) when trained on images showing the fetal brain (abdomen). Visualization with gradient-weighted class activation mapping shows that the classifiers appear to rely on anatomical features. We conclude that fetal re-identification in ultrasound images may be feasible. However, more work on additional datasets, including images from multiple pregnancies and several subsequent examinations, is required to ensure and investigate performance stability and explainability.Clinical relevance- To date, fetuses in multiple pregnancies cannot be distinguished between ultrasound examinations. This work provides the first evidence for feasibility of fetal re-identification in pregnancy ultrasound images. This may improve diagnostic capabilities in clinical practice in the future, such as longitudinal analysis of fetal changes or abnormalities.


Assuntos
Aprendizado Profundo , Ultrassonografia Pré-Natal , Gravidez , Humanos , Feminino , Ultrassonografia Pré-Natal/métodos , Feto/diagnóstico por imagem , Gravidez Múltipla , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...