Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Langmuir ; 31(30): 8519-29, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-26169072

RESUMO

Microelectromechanical sensors based on surface acoustic wave (SAW) and quartz crystal microbalance (QCM) transducers possess substantial potential as online elemental mercury (Hg(0)) vapor detectors in industrial stack effluents. In this study, a comparison of SAW- and QCM-based sensors is performed for the detection of low concentrations of Hg(0) vapor (ranging from 24 to 365 ppbv). Experimental measurements and finite element method (FEM) simulations allow the comparison of these sensors with regard to their sensitivity, sorption and desorption characteristics, and response time following Hg(0) vapor exposure at various operating temperatures ranging from 35 to 75 °C. Both of the sensors were fabricated on quartz substrates (ST and AT cut quartz for SAW and QCM devices, respectively) and employed thin gold (Au) layers as the electrodes. The SAW-based sensor exhibited up to ∼111 and ∼39 times higher response magnitudes than did the QCM-based sensor at 35 and 55 °C, respectively, when exposed to Hg(0) vapor concentrations ranging from 24 to 365 ppbv. The Hg(0) sorption and desorption calibration curves of both sensors were found to fit well with the Langmuir extension isotherm at different operating temperatures. Furthermore, the Hg(0) sorption and desorption rate demonstrated by the SAW-based sensor was found to decrease as the operating temperature increased, while the opposite trend was observed for the QCM-based sensor. However, the SAW-based sensor reached the maximum Hg(0) sorption rate faster than the QCM-based sensor regardless of operating temperature, whereas both sensors showed similar response times (t90) at various temperatures. Additionally, the sorption rate data was utilized in this study in order to obtain a faster response time from the sensor upon exposure to Hg(0) vapor. Furthermore, comparative analysis of the developed sensors' selectivity showed that the SAW-based sensor had a higher overall selectivity (90%) than did the QCM counterpart (84%) while Hg(0) vapor was measured in the presence of ammonia (NH3), humidity, and a number of volatile organic compounds at the chosen operating temperature of 55 °C.


Assuntos
Ouro/química , Mercúrio/química , Sistemas Microeletromecânicos , Técnicas de Microbalança de Cristal de Quartzo , Som , Adsorção , Tamanho da Partícula , Propriedades de Superfície
2.
Environ Sci Technol ; 49(3): 1578-84, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25407243

RESUMO

Mercury being one of the most toxic heavy metals has long been a focus of concern due to its gravest threats to human health and environment. Although multiple methods have been developed to detect and/or remove dissolved mercury, many require complicated procedures and sophisticated equipment. Here, we describe a simple surface enhanced Raman spectroscopy (SERS) active ZnO/Ag nanoarrays that can detect Hg(2+), remove Hg(2+) and can be fully regenerated, not just from Hg(2+) contamination when heat-treated but also from the SERS marker when exposed to UV as a result of the self-cleaning ability of this schottky junction photocatalyst. The sensors are also highly selective because of the unique way mercury (among other chemicals) interacts with Ag nanoparticles, thus reducing its SERS activity.


Assuntos
Mercúrio/isolamento & purificação , Nanopartículas Metálicas/química , Análise Espectral Raman/métodos , Águas Residuárias/química , Mercúrio/análise , Prata/química , Análise Espectral Raman/instrumentação , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Óxido de Zinco/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...