Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 102: 459-67, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25459946

RESUMO

Bispecific monoclonal IgG antibodies offer increased efficacy by antagonizing two different targets. Assessing drug mechanisms, target engagement and biomarker features, the quantification of free target levels is essential. The anti-Ang2/VEGF-CrossMab (anti-A2V) recognizes soluble vascular endothelial growth factor-A (VEGF-A) and soluble angiopoietin-2 (Ang2). However, an assay for reliable free Ang2 determination is missing. Here, we describe an immunodepletion procedure that allows for selective quantification of free Ang2 target levels by taking into advantage the bispecificity of the therapeutic antibody. The specificity for VEGF was utilized to efficiently eliminate drug-bound Ang2 from plasma samples prior to an established Ang2 measurement. The magnetic bead-based depletion procedure used an anti-idiotypic monoclonal antibody (mAb) specific for the VEGF binding site of anti-A2V (anti-Id-anti-VEGF mAb) to capture the drug along with drug-bound Ang2. High efficiencies of 99.9% were obtained for anti-A2V depletion (concentration range 300 ng/mL to 10(6)ng/mL) reflecting a 1000-fold reduction of drug-bound Ang2. A significant impact of the interaction of anti-Id-anti-VEGF mAb with anti-A2V on the Ang2 binding could be excluded. Moreover, reliable quantification of free Ang2 concentrations in plasma samples was assured by interference testing. Performing advanced free Ang2 determination including the immunodepletion step in parallel to established Ang2 measurement without immunodepletion, we compared free with total Ang2 concentrations in human plasma samples obtained from an anti-A2V Phase 1 clinical study. Samples from untreated patients displayed rather low and equal values for both free and total Ang2. In contrast, samples from drug-treated patients showed a significant reduction of free Ang2 accompanied by an accumulation in total Ang2. These results underline the value of the novel immunodepletion procedure for reliable discrimination of free vs. total target quantification with particular importance for pre-clinical and clinical development of anti-A2V. Moreover, this approach may serve as universal concept for the determination of free target levels of bispecific therapeutic antibodies.


Assuntos
Angiopoietina-2/sangue , Anticorpos Biespecíficos/sangue , Anticorpos Monoclonais/sangue , Antineoplásicos/sangue , Imunoglobulina G/sangue , Fator A de Crescimento do Endotélio Vascular/sangue , Animais , Anticorpos Biespecíficos/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Antineoplásicos/uso terapêutico , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/uso terapêutico , Macaca fascicularis , Fator A de Crescimento do Endotélio Vascular/uso terapêutico
2.
J Pharm Biomed Anal ; 72: 208-15, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23017233

RESUMO

Generic immunoassay formats in animal serum have been described for pharmacokinetic (PK) analysis of human full-length antibodies, but not of human antigen binding fragment (Fab) proteins. Here we characterize two murine monoclonal antibodies (mAb) raised against human immunoglobulin G (IgG) which bind to unique epitopes in the Fab region of human IgG. mAb M-1.7.10 is directed against the constant domain of the kappa light chain and mAb M-1.19.31 binds to the constant domain 1 (CH1) of the heavy chain. Surface plasmon resonance analysis showed that mAb M-1.7.10 does not cross-react with sera from mouse, rat, rabbit, dog, marmoset, rhesus macaque, baboon and cynomolgus monkey, but binds to human and chimpanzee serum (dissociation constant K(D) of 6.8 × 10(-12) and 3.1 × 10(-11)M, respectively). mAb M-1.19.31 shows a higher K(D) for human and chimpanzee IgG (2.0 × 10(-9)M and 5.8 × 10(-10)M, respectively), but also does not bind to serum of the other species. Therefore, mAb M-1.7.10 was used as capture and mAb M-1.19.31 as detection reagent in a generic enzyme linked immunosorbent assay (ELISA) to quantify the human anti-IGF-1R Fab in mouse serum. The generic human Fab assay showed a limit of detection of 31.5 ng/mL anti-IGF-1R Fab. Intra- and inter-assay precision was less than 12% and the accuracy range for all controls was within ±20% of the target concentration. The generic human Fab ELISA was applied to determine serum levels of human anti-IGF-1R Fab after intravenous (iv) administration of 10mg/kg to mice. The resulting concentration-time profile was nearly identical to that obtained by analysis with a validated specific ELISA for anti-IGF-1R Fab. The mean relative concentration of anti-IGF-1R Fab analyzed by the generic assay was 82-118% of that of the specific assay. This equivalence was confirmed in a cynomolgus monkey study with the full length human mAb anti-TROP-2 IgG. Both specific ELISAs used mAb M-1.7.10 as detection reagent and their targets for capturing. In conclusion, the two murine anti-human Fabs are versatile tools as capture and detection reagents for human antibodies in generic and specific PK ELISA formats for animal studies. Their use in specific ELISAs as detection reagents allows the usage of Fc-fusion proteins as capture reagents.


Assuntos
Anticorpos Monoclonais/imunologia , Fragmentos Fab das Imunoglobulinas/sangue , Fragmentos Fab das Imunoglobulinas/imunologia , Macaca fascicularis/sangue , Animais , Anticorpos Anti-Idiotípicos/imunologia , Especificidade de Anticorpos/imunologia , Callithrix/imunologia , Reações Cruzadas/imunologia , Cães , Epitopos/imunologia , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/imunologia , Cadeias kappa de Imunoglobulina/imunologia , Macaca mulatta/imunologia , Masculino , Camundongos , Pan troglodytes/imunologia , Papio/imunologia , Coelhos , Ratos
3.
J Pharm Biomed Anal ; 52(2): 249-54, 2010 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-20083366

RESUMO

Current state of the art bridging ELISA technologies for detection of anti-drug antibodies (ADAs) against therapeutic antibodies bear the risk of false-negative results due to interference by circulating drug. Methods to remove the drug in the sample or sample pre-treatment techniques such as acid dissociation of the immune complexes are limited, laborious and may destroy ADAs resulting again in false-negative results. The immune complex ELISA described in this publication provides a simple solution. It is designed to analyze samples from cynomolgus monkeys dosed with human antibodies; it can be used for all human antibodies since it is independent of the specific antibody and its target. The generic applicability of the ADA assay is enabled by the use of (1) a murine anti-human Fc monoclonal antibody (MAb) as capture reagent; (2) a murine anti-cynomolgus monkey IgG MAb as detection reagent; and (3) an ADA positive control conjugate consisting of cynomolgus IgG complexed with human IgG. In its basic version, the generic ADA ELISA specifically detects only immune complexes formed in vivo. Validation of the ADA assay revealed a lower limit of quantitation of 15.6 ng/mL in serum samples. Intra-assay and inter-assay precision was characterized by a coefficient of variation of less than 10% and accuracy was within 8%. Matrix effects were low as evidenced by a mean recovery of 95%. In vitro pre-incubation of the serum samples with drug makes also the free ADA in the sample amenable to measurement by the immune complex ELISA as demonstrated by analysis of ADAs from two cynomolgus monkey studies with two different antibodies. The generic and versatile nature of this ADA assay favors its use in pilot pharmacokinetic and safety studies in cynomolgus monkeys during candidate selection of antibodies. The assay can help to explain unexpected drug clearance profiles, loss of efficacy or safety events caused by immune complexes and guide further development.


Assuntos
Anticorpos/administração & dosagem , Complexo Antígeno-Anticorpo/imunologia , Tolerância a Medicamentos/imunologia , Soro/imunologia , Animais , Anticorpos/imunologia , Anticorpos Anti-Idiotípicos/imunologia , Anticorpos Monoclonais/genética , Anticorpos Monoclonais/imunologia , Especificidade de Anticorpos , Calibragem , Reações Cruzadas/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/genética , Imunoglobulina G/imunologia , Macaca fascicularis , Masculino , Modelos Imunológicos , Controle de Qualidade , Proteínas Recombinantes/imunologia , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...