Med Phys ; 42(1): 297-304, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25563269

RESUMO

PURPOSE: To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. METHODS: We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. RESULTS: Exradin W1 showed a temperature dependence of -0.225% °C(-1). The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. CONCLUSIONS: The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.


Assuntos
Radioterapia/instrumentação , Calibragem , Elétrons/uso terapêutico , Fótons/uso terapêutico , Temperatura , Incerteza
3.
Phys Med ; 24(1): 3-20, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18061501

RESUMO

The aim of this work is to present the results of an EFOMP's survey on the status of Education and Training of Medical Physics in Europe. This survey has been undertaken by EFOMP in 2005, to update the document "Policy Statement No. 1", which represents the starting point of the EFOMP recommendations on Education and Training in Medical Physics. Ultimate results have been collected at the end of 2006. To perform the survey, a questionnaire was sent to 34 National Member Organisations (NMOs) for Medical Physics, to collect information on the present state of education and training in each European country. Twenty-five countries participated in the enquiry and responded to it. The most outstanding results are as follows: In all countries, the basic requirement to enter the Medical Physics education is a university degree. The length of this university education ranges from 2 to 5 years. Concerning the Post-graduate education in Medical Physics: A nationally approved educational programme is in operation in 16 of the 25 countries. Postgraduate education takes place essentially within 3 different approaches and the total length of Medical Physics education and training ranges from 2 1/2 years to 9 years. In 14 countries, it is mandatory to hold a diploma or license to work as a Medical Physicist. It allows working in all areas of competence (the most mentioned were Radiotherapy, Nuclear Medicine, Diagnostic Radiology and Radiation Protection) in 14 countries, whereas in 4 countries it allows to work only in 1 or 2 areas. Seventeen countries have a register for Medical Physicists. A formal CPD (Continuing Professional Development) programme is in operation in 13 countries.


Assuntos
Currículo/tendências , Educação de Pós-Graduação/tendências , Educação Profissionalizante/tendências , Física Médica/educação , Física Médica/tendências , Sistema de Registros , Ensino/tendências , Coleta de Dados , Europa (Continente) , Física Médica/estatística & dados numéricos
4.
Med Phys ; 34(8): 3323-33, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17879796

RESUMO

To evaluate the dose values predicted by several calculation algorithms in two treatment planning systems, Monte Carlo (MC) simulations and measurements by means of various detectors were performed in heterogeneous layer phantoms with water- and bone-equivalent materials. Percentage depth doses (PDDs) were measured with thermoluminescent dosimeters (TLDs), metal-oxide semiconductor field-effect transistors (MOSFETs), plane parallel and cylindrical ionization chambers, and beam profiles with films. The MC code used for the simulations was the PENELOPE code. Three different field sizes (10 x 10, 5 x 5, and 2 x 2 cm2) were studied in two phantom configurations and a bone equivalent material. These two phantom configurations contained heterogeneities of 5 and 2 cm of bone, respectively. We analyzed the performance of four correction-based algorithms and one based on convolution superposition. The correction-based algorithms were the Batho, the Modified Batho, the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system (TPS), and the Helax-TMS Pencil Beam from the Helax-TMS (Nucletron) TPS. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. All the correction-based calculation algorithms underestimated the dose inside the bone-equivalent material for 18 MV compared to MC simulations. The maximum underestimation, in terms of root-mean-square (RMS), was about 15% for the Helax-TMS Pencil Beam (Helax-TMS PB) for a 2 x 2 cm2 field inside the bone-equivalent material. In contrast, the Collapsed Cone algorithm yielded values around 3%. A more complex behavior was found for 6 MV where the Collapsed Cone performed less well, overestimating the dose inside the heterogeneity in 3%-5%. The rebuildup in the interface bone-water and the penumbra shrinking in high-density media were not predicted by any of the calculation algorithms except the Collapsed Cone, and only the MC simulations matched the experimental values within the estimated uncertainties. The TLD and MOSFET detectors were suitable for dose measurement inside bone-equivalent materials, while parallel ionization chambers, applying the same calibration and correction factors as in water, systematically underestimated dose by 3%-5%.


Assuntos
Algoritmos , Osso e Ossos/patologia , Radiometria/métodos , Dosimetria Termoluminescente/métodos , Calibragem , Simulação por Computador , Humanos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Dosimetria Termoluminescente/instrumentação , Água
5.
Br J Radiol ; 78(932): 721-32, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16046424

RESUMO

The performance assessment and beam characteristics of the Therapax SXT 150 unit, which encompass both low and medium-energy beams, were evaluated. Dose determination was carried out by implementing the International Atomic Energy Agency (IAEA) TRS-398 protocol and measuring all the dosimetric parameters in order to have a solid, consistent and reliable data set for the unit. Mechanical movements, interlocks and applicator characteristics agreed with specifications. The timer exhibited good accuracy and linearity. The output was very stable, with good repeatability, long-term reproducibility and no dependence on tube head orientation. The measured dosimetric parameters included beam first and second half-value layers (HVLs), absorbed dose rate to water under reference conditions, central axis depth dose distributions, output factors and beam profiles. Measured first HVLs agreed with comparable published data, but the homogeneity coefficients were low in comparison with typical values found in the literature. The timer error was significant for all filters and should be taken into consideration for the absorbed dose rate determination under reference conditions as well as for the calculation of treatment times. Percentage depth-dose (PDD) measurements are strongly recommended for each filter-applicator combination. The output factor definition of the IAEA TRS-398 protocol for medium-energy X-ray qualities involves the use of data that is difficult to measure. Beam profiles had small penumbras and good symmetry and flatness except for the lowest energy beam, for which a heel effect was observed.


Assuntos
Radioterapia/instrumentação , Calibragem , Desenho de Equipamento , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Radioterapia/normas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
6.
Med Phys ; 31(10): 2899-911, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15543799

RESUMO

An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by means of the PENELOPE code were performed. Four different field sizes (10 x 10, 5 x 5, 2 x 2, and 1 x 1 cm2) and two lung equivalent materials (CIRS, p(w)e=0.195 and St. Bartholomew Hospital, London, p(w)e=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and the TMS Pencil Beam from the Helax-TMS (Nucletron) treatment planning system. The convolution-superposition algorithm was the Collapsed Cone implemented in the Helax-TMS. The only studied calculation methods that correlated successfully with the measured values with a 2% average inside all media were the Collapsed Cone and the Monte Carlo simulation. The biggest difference between the predicted and the delivered dose in the beam axis was found for the EqTAR algorithm inside the CIRS lung equivalent material in a 2 x 2 cm2 18 MV x-ray beam. In these conditions, average and maximum difference against the TLD measurements were 32% and 39%, respectively. In the water equivalent part of the phantom every algorithm correctly predicted the dose (within 2%) everywhere except very close to the interfaces where differences up to 24% were found for 2 x 2 cm2 18 MV photon beams. Consistent values were found between the reference detector (ionization chamber in water and TLD in lung) and Monte Carlo simulations, yielding minimal differences (0.4%+/-1.2%). The penumbra broadening effect in low density media was not predicted by any of the correction-based algorithms, and the only one that matched the experimental values and the Monte Carlo simulations within the estimated uncertainties was the Collapsed Cone Algorithm.


Assuntos
Algoritmos , Pulmão/fisiologia , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Software , Carga Corporal (Radioterapia) , Simulação por Computador , Pulmão/efeitos da radiação , Radiometria/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador
7.
Med Phys ; 31(9): 2534-42, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15487735

RESUMO

The feasibility of dual bias dual metal oxide semiconductor field effect transistors (MOSFETs) for entrance in vivo dose measurements in high energy x-rays beams (18 MV) was investigated. A comparison with commercially available diodes for in vivo dosimetry for the same energy range was performed. As MOSFETs are sold without an integrated build-up cap, different caps were tested: 3 cm bolus, 2 cm bolus, 2 cm hemispherical cap of a water equivalent material (Plastic Water) and a metallic hemispherical cap. This metallic build-up cap is the same as the one that is mounted on the in vivo diode used in this study. Intrinsic precision and response linearity with dose were determined for MOSFETs and diodes. They were then calibrated for entrance in vivo dosimetry in an 18 MV x-ray beam. Calibration included determination of the calibration factor in standard reference conditions and of the correction factors (CF) when irradiation conditions differed from those of reference. Correction factors for field size, source surface distance, wedge, and temperature were determined. Sensitivity variation with accumulated dose and the lifetime of both types of detectors were also studied. Finally, the uncertainties of entrance in vivo measurements using MOSFET and diodes were discussed. Intrinsic precision for MOSFETs for the high sensitivity mode was 0.7% (1 s.d.) as compared to the 0.05% (1 s.d.) for the studied diodes. The linearity of the response with dose was excellent (R2 = 1.000) for both in vivo dosimetry systems. The absolute values of the studied correction factors for the MOSFETs when covered by the different build-up caps were of the same order of those determined for the diodes. However, the uncertainties of the correction factors for MOSFETs were significantly higher than for diodes. Although the intrinsic precision and the uncertainty on the CF was higher for MOSFET detectors than for the studied diodes, the total uncertainty in entrance dose determination, once they were calibrated, was of 2.9% (1 s.d.) while for diodes it was 2.0% (1 s.d.). MOSFETs showed no sensitivity variation with accumulated dose or temperature. When used in the high sensitivity mode, after approximately 50 Gy of accumulated dose MOSFETs could no longer be used as radiation dosimeters. In conclusion, MOSFETs can be used for entrance in vivo dosimetry in high energy x-rays beams if covered by an appropriate build-up cap. Metallic build-up caps, such as those used for in vivo diodes, have the advantage of greater patient comfort and less perturbation of the treatment field than the other build-up caps tested, while keeping the correction factors of the same order.


Assuntos
Análise de Falha de Equipamento , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Carga Corporal (Radioterapia) , Estudos de Viabilidade , Dosagem Radioterapêutica , Radioterapia Conformacional/instrumentação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Transistores Eletrônicos
8.
Med Phys ; 27(6): 1287-93, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10902558

RESUMO

This paper compares two different types of diodes designed to cover the energy range from 16 to 25 MV, one n-type (diode-A) and the other p-type (diode-B). A 18 MV x-ray beam has been used for all tests. Signal stability postirradiation, intrinsic precision and linearity of response with dose, front-back symmetry, and dose decrease under the diode were studied. Also, the water equivalent thickness of the build up caps was determined. Both types of diodes were calibrated to give entrance dose. Entrance correction factors for field size, tray, source skin distance, angle, and wedge were determined. Finally, the effect of dose rate, temperature and accumulated dose on the diode's response were studied. Only diode-A had full build-up for 18 MV x rays and standard irradiation conditions. Field size correction factor was about 2%-4% for field sizes bigger than 20 x 20 cm2 for both diodes. Tray correction factor was negligible for diode-A while diode-B would overestimate the dose by a 2% for a 40 x 40 cm2 field size if the correction factor was not applied. Wedge correction factors are only relevant for the 60 degrees wedge, being the correction factor for diode-A significantly higher than for diode-B. Diode-A showed less temperature dependence than diode-B. Sensitivity dependence on dose per pulse was a 1.5% higher for diode-A than for diode-B and therefore a higher SSD dependence was found for diode-A. The loss of sensitivity with accumulated radiation dose was only about 0.3% for diode-A, after 300 Gy, while it amounted to 8% for diode-B. Weighing the different correction factors for both types of diodes no conclusions about which type is better can be driven. From these results it can be also seen that the dependence of the diode response on dose rate in a pulsed beam does not seem to be associated with the fact of being n-type or p-type but could be related to the doping level of the diodes.


Assuntos
Radiometria/instrumentação , Radioterapia de Alta Energia , Fenômenos Biofísicos , Biofísica , Humanos , Radiometria/estatística & dados numéricos , Dosagem Radioterapêutica
9.
Radiother Oncol ; 49(1): 91-8, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9886703

RESUMO

BACKGROUND AND PURPOSE: During TBI techniques an accurate determination of the dose distribution is very difficult when using commercial treatment planning systems. In order to determine the midplane dose, an algorithm was developed based on the use of in vivo dosimetry. MATERIALS AND METHODS: Scanditronix EDP-30 diodes were placed at the entrance and the exit surface for in vivo dosimetry. The proposed algorithm was validated firstly in a regular and homogeneous phantom of different thickness with an ionization chamber and TL dosimeters and secondly in an Alderson anthropomorphic phantom with TL dosimeters. In this study, in vivo measurements were evaluated in 60 patients and furthermore, in 20 of them, the midplane dose calculated with this algorithm was compared with the method described by Rizzotti A, Compri C, Garusi GF. Dose evaluation to patients irradiated by 60Co beams, by means of direct measurement on the incident and on the exit surfaces. Radiother. Oncol. 1985;3:279-283. RESULTS: No differences were found between the two methods. The differences between dose values calculated with both methods and dose values measured with the ionization chamber and TL dosimeters were within +/-22% and +/-4%, respectively, in the regular and homogeneous phantom and within +/-2% in the Alderson phantom. The algorithm was useful in calculating the midplane dose when heterogeneities as lungs were present. Even when partial transmission blocks were used to reduce the dose to the lungs, the algorithm with modified correction factors gave a midplane lung dose in the Alderson phantom within 1.3% of the measurements with TL dosimeters. For 360 patients' measurements in each A-P and P-A field, the relative deviations were analyzed between the measured and calculated entrance, exit dose and midplane dose and the prescribed dose, always applying the temperature correction factor. These deviations at the entrance dose were within +/-4%. Greater deviations were found for the exit dose measurements. Deviations larger than +/-10% corresponded in general to obese patients, with a thickness over 25 cm. The relative deviations between the total received and prescribed midplane doses in 60 patients were within +/-3%. CONCLUSIONS: The results indicate excellent correspondence between the total prescribed and calculated midplane doses using this algorithm while also no significant differences were found when the Rizzotti method was used. Comparison between doses measured with TL dosimeters in the core of Alderson phantom lungs and doses calculated from in vivo measurements showed that the proposed algorithm could be used in the presence of heterogeneities even when partial transmission blocks were used. The temperature correction factor must be applied in order to avoid a 2-3% dose overestimation.


Assuntos
Irradiação Corporal Total , Humanos , Modelos Estruturais , Dosagem Radioterapêutica
10.
Radiother Oncol ; 38(3): 247-51, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8693106

RESUMO

The aim of this paper is to discuss the measurements carried out to implement 'in vivo dosimetry' with EDP-30 diodes in total body irradiation (TBI) techniques. Exit calibrations and calibrations behind cerrobend protection blocks showed the importance of calibrating diodes in all relevant clinical conditions. Special attention was given to calibration of diodes behind cerrobend blocks. Dependence of the calibration factors on the thickness of the shielding blocks was, therefore, studied. This dependence was again studied after adding a wax cap to the diode and when the ionisation chamber was placed at the same depth as the measuring point of the diode. Temperature dependence in diode sensitivity and dependence on accumulated dose for diodes response and for temperature correction factors were also examined.


Assuntos
Dosagem Radioterapêutica , Irradiação Corporal Total , Calibragem , Humanos , Imagens de Fantasmas , Radiometria/instrumentação , Semicondutores
11.
Int J Oncol ; 2(5): 803-5, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-21573629

RESUMO

Fourteen patients with recurrent or persistent carcinoma of the oral cavity or oropharynx were treated with Au-198 grain implants at the Santa Creu i Sant Pau Hospital from June 1987 through April 1991. Five patients presented recurrent carcinoma, four patients persistent carcinoma, and five patients a second primary. Local control was achieved with Au-198 implants in six patients (42.8%) at 8, 16, 23, 29, 39 and 53 months following treatment. Seven patients died of local recurrence or persistent disease at 5, 7, 7, 10, 10, 12 and 15 months after interstitial implant. Three patients (21.4%) died of significant complications of salvage irradiation (Hemorrhage in two patients and edema in one patient) at 0.5, 8 and 16 months following treatment. Three patients of fourteen (21.4%) are alive and well at 53, 39 and 23 months after salvage Au-198 grain implant. Considerations regarding the usefulness of Au-198 grain implants in the treatment of recurrent or persistent oral and oropharyngeal cancer are discussed.