Med Phys ; 41(2): 022305, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24506643

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheter in vitro to better understand their efficacy. METHODS: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image based methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. RESULTS: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R(2) = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. CONCLUSIONS: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.


Assuntos
Catéteres , Fenômenos Magnéticos , Imagem por Ressonância Magnética Intervencionista , Imagem Óptica , Modelos Teóricos
2.
Acad Radiol ; 18(3): 270-6, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21075017

RESUMO

RATIONALE AND OBJECTIVES: The aims of this study were to assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging and to investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. MATERIALS AND METHODS: A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed on a 1.5-T magnetic resonance system using a vessel phantom, body radiofrequency coil, and steady-state pulse sequence. Resistive heating was measured with water flowing over a polyimide-tip catheter or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumina-tip catheter for up to 5 minutes. RESULTS: After application of up to 1 W of direct current power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cm(3)/s, and 7.9°C/W at 1 cm(3)/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cm(3)/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. CONCLUSIONS: Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer.


Assuntos
Cateterismo Periférico/instrumentação , Catéteres , Imagem por Ressonância Magnética Intervencionista/instrumentação , Magnetismo/instrumentação , Cirurgia Assistida por Computador/instrumentação , Queimaduras por Corrente Elétrica/etiologia , Queimaduras por Corrente Elétrica/prevenção & controle , Cateterismo Periférico/efeitos adversos , Impedância Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Humanos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Cirurgia Assistida por Computador/efeitos adversos