1.
Health Phys ; 86(2 Suppl): S8-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14744062

RESUMO

Ethics is defined in the New World Dictionary as ". . . moral principles governing appropriate conduct for an individual or group." The Health Physics Membership Directory contains 2 references for professional conduct for health physicists. The first is for members of the Health Physics Society. The second is for Certified Health Physicists. They are similar: A health physicist must always maintain the highest ethical standards whether beginning a career or having practiced for decades. A review of some key principles by example will hopefully demonstrate how to avoid ethical dilemmas for health physicists.


Assuntos
Ética Profissional , Física Médica/ética , Serviços Terceirizados/ética , Proteção Radiológica/normas , Segurança , Responsabilidade Social , Revelação da Verdade/ética , Conflito de Interesses , Competência Profissional , Estados Unidos
2.
Health Phys ; 83(11 Suppl): S68-70, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12458923

RESUMO

Medical accelerators operating over 10 MV can induce short-lived radionuclides in components near the beam and in the air (McGinley 1992). We evaluated a Clinac 2100 C/D at 18 MV photon mode for radionuclidic exposure, contamination, and airborne potential to the accelerator staff entering the room after patient radiation treatment. The gantry, patient couch, wedges, floor, and air were activated. Most activated components appear to decay with a half-life of 2.5 min, except the gantry and port with half-lives approaching 10 min. The highest exposure was from the port at <2 mR h(-1). No removable contamination on any activated component was detected including coolant water in the machine. Airborne radionuclides were measured in the room and at the roof exhaust. The airborne potential is short lived because of ventilation and decay with the highest exposure of 0.3 mR h(-1) lasting for 1 s. Our measurements support the insignificant exposures received by accelerator staff wearing whole body personnel monitors. Accelerator roof effluents to unrestricted areas during patient treatments indicate that regulatory limits are not exceeded.


Assuntos
Aceleradores de Partículas , Exposição Ambiental , Desenho de Equipamento , Física Médica , Exposição Ocupacional/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...